GROADA-AC120V-5KW-RCD 부하 은행 제조 업체
The GROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate nonlinea...
| 모델 | AC220V-5KW-RCD는 | AC220V-10KW-RCD는 | AC220V-15KW-RCD는 | AC220V-20KW-RCD는 | AC380V-30KW-RCD는 | AC380V-50KW-RCD는 | AC380V-60KW-RCD는 | AC380V-100KW-RCD는 | AC380V-200KW-RCD는 |
| 정격 전력 | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| 입력 현재 | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| 크기 (폭 * 깊이 * 높이 mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| 무게 | 50KG의 | 80KG의 | 100KG의 | 130KG의 | 200KG의 | 300KG의 | 350KG의 | 450KG의 | 550KG의 |
| 입력 전압 | AC220 / 230V | AC380/400V | |||||||
| 다른 입력 전압은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||||
| 최소 부하 | 100W | 100W | 100W | 100W | 100W | 1KW | 1KW | 1KW | 1KW |
| 다른 최소 적재 힘은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||||
| 전반적인 정확도 | 3% (다른 정확도 요구 사항은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 전력 요소 | PF = 0.6 ~ 1.0 | ||||||||
| 최고 계수 | 2에서 3까지 | ||||||||
| 제어 모드 | 지역 수동/원격 호스트 컴퓨터 (지역 수동 제어 모드: 차단기/버튼/터치 스크린 선택적 3 방향, 다른 방법은 필요에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 원격 인터페이스 | RS232/RS485/USB/RJ45/CAN/GPIB (다른 인터페이스 형태는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 보호 기능 | 비상 정지 보호, 과온 보호, 팬 부하 인터로크 보호, 접지 보호 (과전압 보호, 과전류 보호, 단회로 보호, 팬 과부하, 부족한 공기 용량을 선택하십시오) | ||||||||
| 작동 전원 공급 | AC220V는 | AC220V / AC380V | |||||||
| 표시 정확도 | 0.5 수준 (다른 명시적인 정밀도는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 표시 매개 변수 | 전압, 전류, 힘, 주파수, 전력 요인 등. (다른 명시적인 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 차가운 확실한 방법 | 측면 공기 입구 및 위 공기 출구 (다른 공기 출구 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 보호 수준 | IP20 (다른 보호 수준은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 외관 색깔 | RAL7035 (다른 색깔은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 작동 온도 | -10 ℃ ~ 55 ℃ | ||||||||
| 상대 습도 | ≤95%RH | ||||||||
| 고도 | ≤ 2500 m | ||||||||
TheGROADA AC220V 40kW RCD 부하 은행복잡한 저항, 용량 및 유도 부하를 시뮬레이션하기 위해 설계된 최신 테스트 장치입니다.전력 시스템 엔지니어와 시설 관리자에게 실제 운영 조건에서 시스템 성능, 안정성 및 탄력을 확인할 수 있는 신뢰할 수 있는 솔루션을 제공합니다.이 부하 은행은 이상적입니다UPS 시스템, 인버터, 발전기, 데이터 센터 및 기타 중요한 인프라중단되지 않는 운영과 최적의 전력 품질을 보장합니다.
| 특징 | 명세 |
|---|---|
| 정격 전력 | 40kW의 |
| 전압 | AC 220V |
| 로드 유형 | RCD (저항, 전용량, 유도) |
| 전력 인자 범위 | 0.6 – 1.0 |
| 주파수 | 50/60 Hz의 |
| 최대 현재 | 180A는 |
| 냉각 방법 | 강제 공기 냉각 |
| 제어 인터페이스 | 실시간 모니터링을 가진 고급 터치스크린 |
| 안전 특징 | 과부하 보호, RCD 보호, 비상 종료 |
TheRCD 부하 구성비선형 전기 부하의 정확한 시뮬레이션을 허용하여 엔지니어가 실제 조건에서 시스템이 어떻게 행동하는지 테스트할 수 있습니다.그것의고전류 용량 및 조절 가능한 전력 요소다양한 장비를 테스트하는 데 유연성을 보장합니다.
The GROADA AC220V 40kW RCD Load Bank is engineered for versatility across multiple industries:
UPS 시스템 테스트
Evaluate uninterruptible power supplies under varying load conditions to ensure they can handle dynamic energy demands and maintain output stability.
Inverter Performance Validation
Test inverters in renewable energy setups and industrial environments to measure response under non-linear loads.
Data Center Power Resilience
Simulate realistic IT load profiles to verify critical infrastructure can sustain operations during peak and fluctuating demand.
발전기 부하 테스트
Accurately simulate complex load patterns to ensure standby and emergency generators operate reliably under non-linear conditions.
Industrial Power Systems
Analyze the impact of resistive, inductive, and capacitive loads on industrial motor drives, switchgear, and electrical distribution systems.
The GROADA RCD Load Bank is built to meet global industry standards, ensuring safe, accurate, and reliable testing:
IEEE 1547 – Interconnection of distributed resources with electric power systems
NFPA 110 – Emergency and standby power system standards
ISO 8528-10 – Load acceptance procedures for generating sets
IEC 62040 – Performance and testing requirements for uninterruptible power systems
These certifications reflect the highest level of reliability, safety, and industry compliance, making it suitable for both commercial and industrial applications.
The load bank’s advanced design allows for in-depth testing scenarios:
Dynamic Load Simulation
Test power systems’ response to rapid load changes, simulating real-life operational conditions.
Harmonic Distortion Analysis
Evaluate how non-linear loads affect voltage quality, equipment performance, and system efficiency.
Transient Response Testing
Assess system stability during sudden changes, ensuring critical power systems maintain operational continuity.
Comprehensive Load Management
Adjust resistive, inductive, and capacitive components independently to replicate a wide range of load behaviors.
정밀 부하 시뮬레이션 – Accurately replicates real-world nonlinear electrical loads for comprehensive system testing.
사용자 친화적 인 인터페이스 – Intuitive touchscreen control with real-time monitoring simplifies operations and improves testing efficiency.
견고한 안전 메커니즘 – Integrated protections safeguard both personnel and equipment during rigorous testing.
Versatile Industrial Applications – Suitable for data centers, renewable energy, industrial plants, and more.
Global Standards Compliance – Provides assurance of testing reliability and performance consistency across regions.
Investing in the GROADA RCD 로드 은행 ensures your critical power systems are rigorously tested, optimized, and ready for reliable operation under complex electrical loads. It is an indispensable tool for engineers, technicians, and facility managers seeking accuracy, safety, and efficiency in power system evaluation.