GROADA-AC346V-50KVA-RL banque de charge inductive résistive
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet design...
| Modèle | AC220V-6KW-R | AC380Le V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Puissance nominale | 0 à 6KW | 0-30KW | 0 à 60KW | 0 à 100KW | 0-200KW | 0-400KW | 0-500KW | 0 à 1000KW |
| Taille (largeur * profondeur * hauteur mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Poids | 25 kg | 80 kg | 130 kg | 180kg | 250 kg | 550kg | 650kg | 1100kg |
| Courant d'entrée | 0 à 30A | 0 à 45A | 0 à 90A | 0 à 150A | 0 à 300A | 0 à 600A | 0 à 750A | 0 à 1500A |
| Chargement minimum | 100 watts | 100 watts | 500W | 1 kilowatt | 1 kilowatt | 5 kilowatts | 10 kilowatts | 50 kilowatts |
| Autre puissance de charge minimale peut être personnalisée selon les exigences | ||||||||
| Tension d'entrée | AC220 / 230V | AC380 / 400V | ||||||
| Autre tension d'entrée peut être personnalisée selon les exigences | ||||||||
| Puissance | PF = 1,0 | |||||||
| Précision globale | 3% (autres exigences de précision peuvent être personnalisées selon les exigences) | |||||||
| Mode de commande | Ordinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin) | |||||||
| Interface à distance | RS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences) | |||||||
| Fonction de protection | Protection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant) | |||||||
| Alimentation électrique de travail | AC220V | AC220V / 380V | AC380V | |||||
| Précision de l'affichage | niveau 0,5 (autre précision explicite peut être personnalisée selon les exigences | |||||||
| Paramètres d'affichage | Voltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences) | |||||||
| Froid façon sûre | En avant et en dehors | Entrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences) | ||||||
| Niveau de protection | IP20 (autre niveau de protection peut être personnalisé selon les exigences) | |||||||
| Couleur d'apparence | RAL7035 (autres couleurs peuvent être personnalisées selon les exigences) | |||||||
| Température de travail | -10 ℃ ~ 55 ℃ | |||||||
| Humidité relative | ≤95% RH | |||||||
| Altitude | ≤ 2500 m | |||||||
LeGROADA AC520V-40A-R is a premium resistive AC load bank meticulously engineered for precision testing, maintenance, and verification of AC power systems. Designed for industrial, commercial, and renewable energy applications, this load bank allows engineers and technicians to simulate real-world electrical loads safely and accurately. It ensures your power systems—including generators, UPS, and energy storage units—operate at peak efficiency under both normal and extreme conditions.
High-Voltage Capacity – Supports 520V AC, adaptable for a wide range of industrial power systems.
Substantial Load Handling – Up to 40A load ensures comprehensive testing scenarios.
Intelligent Digital Control – Equipped with a sophisticated control panel for precise load adjustments and monitoring.
Robust & Durable Construction – Crafted with premium components to withstand rigorous testing environments.
Advanced Safety Protections – Integrated over-temperature sensors, circuit breakers, and fail-safe mechanisms ensure safe operation.
Compact & Portable Design – Facilitates easy integration into labs, power plants, or on-site generator testing locations.
The GROADA AC520V-40A-R is indispensable in sectors where power reliability is critical:
Test du générateur – Verifies generator capacity, efficiency, and endurance under simulated real-world loads.
UPS Systems Evaluation – Ensures uninterruptible power systems are fully operational and compliant with performance standards.
Data Centers & Critical Facilities – Validates electrical infrastructure reliability, minimizing downtime risk.
Renewable Energy Testing – Provides accurate load simulation for solar, wind, and hybrid energy installations.
Electrical Engineering Labs – Offers precise load testing for research, development, and quality assurance.
The global AC load bank industry is expanding rapidly, driven by:
Rising demand for resilient power infrastructure across industries.
Accelerated adoption of renewable energy and microgrid technologies.
Increasing regulatory standards for generator and UPS performance.
Insight: Engineers and facility managers prioritize reliable, safe, and precise load testing equipment to prevent downtime and costly system failures. The GROADA AC520V-40A-R meets these market needs with unmatched quality and precision.
Precision Testing: Ensures accurate simulation of AC loads for robust system evaluation.
Versatility: Suitable for industrial generators, UPS systems, renewable energy setups, and lab applications.
Durability: Built to endure frequent testing and harsh environmental conditions.
Global Compliance: Designed to meet international safety and operational standards.
Expert Support: Backed by GROADA’s dedicated service and technical expertise.
| Spécification | Détails |
|---|---|
| Modèle | AC520V-40A-R |
| Voltage | 520V AC |
| Courant maximum | 40A |
| Type de charge | Resistive |
| Interface de contrôle | Digital Panel with Real-Time Monitoring |
| Safety | Over-Temperature Protection, Circuit Breakers |
| Applications | Generator Testing, UPS, Data Centers, Renewable Energy Systems |
With the GROADA AC520V-40A-R, experience precision, reliability, and efficiency in power system testing. Whether ensuring backup generator readiness or evaluating UPS and renewable energy systems, this load bank delivers the confidence and accuracy your operations demand.
Trust GROADA to power your performance—where safety, innovation, and reliability converge.