GROADA-DC1000V-200KW-R banque de charge continue
GROADA-DC1000V-200KW-R DC Charging Load_Shenzhen Guang Lu Da Electronics Co., Ltd. is a high-tech en...
| Puissance nominale | 0 à 6KW | 0-30KW | 0 à 60KW | 0 à 100KW | 0-200KW | 0-400KW | 0-500KW | 0 à 1000KW |
| Taille (largeur * profondeur * hauteur mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Poids | 25 kg | 80 kg | 130 kg | 180kg | 250 kg | 550kg | 650kg | 1100kg |
| Courant d'entrée | 0 à 30A | 0 à 45A | 0 à 90A | 0 à 150A | 0 à 300A | 0 à 600A | 0 à 750A | 0 à 1500A |
| Puissance | PF = 1,0 | |||||||
| Précision globale | 3% (autres exigences de précision peuvent être personnalisées selon les exigences) | |||||||
| Mode de commande | Ordinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin) | |||||||
| Interface à distance | RS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences) | |||||||
| Fonction de protection | Protection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant) | |||||||
| Précision de l'affichage | niveau 0,5 (autre précision explicite peut être personnalisée selon les exigences | |||||||
| Paramètres d'affichage | Voltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences) | |||||||
| Froid façon sûre | En avant et en dehors | Entrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences) | ||||||
| Niveau de protection | IP20 (autre niveau de protection peut être personnalisé selon les exigences) | |||||||
| Couleur d'apparence | RAL7035 (autres couleurs peuvent être personnalisées selon les exigences) | |||||||
| Température de travail | -10 ℃ ~ 55 ℃ | |||||||
| Humidité relative | ≤95% RH | |||||||
| Altitude | ≤ 2500 m | |||||||
As the global electric vehicle (EV) market accelerates, the demand for reliable and efficient EV charging infrastructure intensifies. Ensuring the performance and safety of charging stations is paramount. The GROADA DC750V-50KW-R Charging Pile Load Bank emerges as a pivotal solution, offering advanced testing capabilities to simulate real-world charging scenarios.
Voltage Range: Supports up to 750V DC, accommodating a diverse range of EV charging systems.
Power Capacity: Delivers a maximum load of 50kW, suitable for testing both low and high-power charging stations.
Type de charge: Features a resistive load design, providing stable and accurate simulations of actual charging conditions.
Control Interface: Equipped with an intuitive touch screen interface, allowing for seamless operation and real-time monitoring.
Safety Features: Incorporates overcurrent, overvoltage, and thermal protection mechanisms to ensure the safety of both equipment and personnel.
The GROADA DC750V-50KW-R Load Bank serves multiple critical functions in the development and maintenance of EV charging stations:
Design Validation: Engineers utilize the load bank to simulate diverse EV charging profiles, ensuring that charging stations are designed to handle expected loads efficiently.
Performance Testing: Regular testing with the load bank verifies that charging stations maintain optimal performance under varying load conditions.
Compliance Assurance: Facilitates adherence to international standards such as IEC 61851 and national regulations, streamlining the certification process.
Diagnostic Tool: Serves as an essential tool for identifying and rectifying issues in charging equipment, thereby minimizing downtime and enhancing reliability.
Adhering to established standards is crucial for ensuring the safety and efficiency of EV charging stations:
IEC 61851: Specifies general requirements for EV charging systems, encompassing safety measures and communication protocols.
GB/T 20234.2: Chinese national standard outlining the technical requirements for AC/DC charging connectors and communication protocols.
UL 2202: Standard for the safety of EV charging equipment in the United States, focusing on electrical and mechanical safety aspects.
Utilizing the GROADA DC750V-50KW-R Load Bank ensures that testing procedures align with these standards, promoting the development of safe and reliable charging infrastructure.
The GROADA DC750V-50KW-R Charging Pile Load Bank is an indispensable tool for the EV charging industry. By providing accurate simulations of real-world charging scenarios, it enables manufacturers and operators to deliver high-quality, compliant, and safe charging solutions. Investing in such advanced testing equipment is essential for the sustainable growth of the EV industry and the transition towards a greener future.