GROADA-AC220V-15KW-RLC Banque de charge Fabricant
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| Modèle | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Puissance nominale | RLC = 10KVA | RLC = 30KVA | RLC = 60KVA | RLC = 100KVA | RLC = 200KVA | RLC = 300KVA |
| R = 10KW; L = 10KVA C = 10KVA | R = 30KW; L = 30KVA; C = 30KVA | R = 60KW; L = 60KVA; C = 60KVA | R = 100KW; L = 100KVA; C = 100KVA | R = 200KW; L = 200KVA; C = 200KVA | R = 300KW; L = 300KVA; C = 300KVA | |
| Autre puissance peut être personnalisée selon les exigences | ||||||
| Taille (largeur * profondeur * hauteur mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Poids | 120 kg | 380kg | 580kg | 880 kg | 1500 kg | 2500kg |
| Tension d'entrée | AC220 / 230V | AC380 / 400V | ||||
| Autre tension d'entrée peut être personnalisée selon les exigences | ||||||
| Courant d'entrée | 0 à 45A | 0 à 45A | 0 à 90A | 0 à 150A | 0 à 300A | 0 à 450A |
| Chargement minimum | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 1KW; L = 1KVA; C = 1KVA | R = 1KW; L = 1KVA; C = 1KVA |
| Autre puissance de charge minimale peut être personnalisée selon les exigences | ||||||
| facteur de puissance | PF = 0,1 ~ 1,0 (autre facteur de puissance peut être personnalisé selon les exigences) | |||||
| Précision globale | 3% (autres exigences de précision peuvent être personnalisées selon les exigences) | |||||
| Mode de commande | Ordinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin) | |||||
| Interface à distance | RS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences) | |||||
| Fonction de protection | Protection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant) | |||||
| Alimentation électrique de travail | AC220V | AC220V / 380V | AC380V | |||
| Précision de l'affichage | Niveau 0,5 (autre précision explicite peut être personnalisée selon les exigences) | |||||
| Paramètres d'affichage | Voltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences) | |||||
| Froid façon sûre | Entrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences) | |||||
| Niveau de protection | IP20 (autre niveau de protection peut être personnalisé selon les exigences) | |||||
| Couleur d'apparence | RAL7035 (autres couleurs peuvent être personnalisées selon les exigences) | |||||
| Température de travail | -10 ℃ ~ 55 ℃ | |||||
| Humidité relative | ≤95% RH | |||||
| Altitude | ≤ 2500 m | |||||
Ensure the reliability and performance of your power generation and electrical systems with the GROADA AC380V-30KW-RLC Load Bank. Engineered for precision, flexibility, and safety, this advanced load bank combines Charges résistives (R), inductives (L) et capacitives (C) to simulate real-world electrical conditions, making it an indispensable tool for industries that demand consistent and reliable power delivery.
The GROADA AC380V-30KW-RLC Load Bank is designed to replicate operational loads of generators, UPS systems, and other critical power equipment with high accuracy. It provides a comprehensive solution for testing performance under various conditions, including full load, partial load, and complex reactive loads.
Key Specifications:
Puissance nominale:30 kW
Tension nominale:AC 380V, 3 phases
Fréquence : 50 Hz
Types de charge: Resistive (R), Inductive (L), Capacitive (C)
Facteur de puissance réglable: 0.1 to 1.0
Control Modes: Local panel control and optional remote control
Safety Features: Overload protection, short circuit protection, over-temperature alarms
Load Regulation: Precise and stable output for accurate testing
Simulation complète de charge
Simulate resistive, inductive, and capacitive loads simultaneously to replicate real-world conditions accurately, enabling precise performance evaluation of generators, UPS, and renewable energy systems.
High Precision Control
Adjustable load steps and fine-tuned regulation ensure testing accuracy up to 0.5%, providing reliable data for critical decision-making.
Robust Safety Mechanisms
Equipped with multiple safety protections, including overload, short circuit, and thermal monitoring, guaranteeing safe operation even under high-stress conditions.
Flexible Operation
Offers both local panel control and remote control options, giving operators flexibility in diverse testing environments and facilitating integration with automated test systems.
Durable & Reliable Design
Industrial-grade components and advanced thermal management ensure long-term stability, reducing maintenance costs and improving lifecycle performance.
The GROADA AC380V-30KW-RLC Load Bank is ideal for industries where power reliability and efficiency are critical:
Power Generation: Test generator performance under simulated loads to prevent unexpected failures.
UPS Systems: Validate the capacity and stability of uninterruptible power supplies.
Centres de données : Ensure infrastructure can handle peak demand without downtime.
Renewable Energy: Simulate load conditions for solar, wind, and hybrid energy systems.
Industrial & Emergency Systems: Test backup power systems for factories, hospitals, and critical services.
The global load bank market is growing rapidly, driven by increasing demand for reliable power systems, expansion of data centers, and stricter power quality standards. Recent studies project the market to reach USD 387 million by 2032, with a CAGR of 3.7% from 2025 to 2032.
As industries adopt renewable energy and implement energy efficiency initiatives, high-performance load testing solutions like the GROADA AC380V-30KW-RLC Load Bank become essential to ensure operational safety, compliance, and cost optimization.
Reliable Performance: Accurately replicates complex load conditions for thorough testing.
Safety First: Advanced protections minimize risk during testing.
Flexible & Intelligent: Local and remote control options adapt to diverse operational environments.
Industry-Trusted: Built to meet international standards and the rigorous demands of modern power systems.