GROADA-AC220V-5KW-R banque de charge AC de type rack
GROADA-AC220V-5KW-R Rack Type AC Load Box_Shenzhen Guangluda Electronics Co., Ltd. is a high-tech en...
| Modèle | AC220V-6KW-R | AC380Le V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Puissance nominale | 0 à 6KW | 0-30KW | 0 à 60KW | 0 à 100KW | 0-200KW | 0-400KW | 0-500KW | 0 à 1000KW |
| Taille (largeur * profondeur * hauteur mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Poids | 25 kg | 80 kg | 130 kg | 180kg | 250 kg | 550kg | 650kg | 1100kg |
| Courant d'entrée | 0 à 30A | 0 à 45A | 0 à 90A | 0 à 150A | 0 à 300A | 0 à 600A | 0 à 750A | 0 à 1500A |
| Chargement minimum | 100 watts | 100 watts | 500W | 1 kilowatt | 1 kilowatt | 5 kilowatts | 10 kilowatts | 50 kilowatts |
| Autre puissance de charge minimale peut être personnalisée selon les exigences | ||||||||
| Tension d'entrée | AC220 / 230V | AC380 / 400V | ||||||
| Autre tension d'entrée peut être personnalisée selon les exigences | ||||||||
| Puissance | PF = 1,0 | |||||||
| Précision globale | 3% (autres exigences de précision peuvent être personnalisées selon les exigences) | |||||||
| Mode de commande | Ordinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin) | |||||||
| Interface à distance | RS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences) | |||||||
| Fonction de protection | Protection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant) | |||||||
| Alimentation électrique de travail | AC220V | AC220V / 380V | AC380V | |||||
| Précision de l'affichage | niveau 0,5 (autre précision explicite peut être personnalisée selon les exigences | |||||||
| Paramètres d'affichage | Voltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences) | |||||||
| Froid façon sûre | En avant et en dehors | Entrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences) | ||||||
| Niveau de protection | IP20 (autre niveau de protection peut être personnalisé selon les exigences) | |||||||
| Couleur d'apparence | RAL7035 (autres couleurs peuvent être personnalisées selon les exigences) | |||||||
| Température de travail | -10 ℃ ~ 55 ℃ | |||||||
| Humidité relative | ≤95% RH | |||||||
| Altitude | ≤ 2500 m | |||||||
LeGROADA AC230V-6KW-R Rack-Mounted Load Bank is a high-precision, resistive load testing device designed for professionals in data centers, electrical engineering, and power distribution systems. It accurately simulates real-world electrical loads, allowing engineers and technicians to verify the performance, stability, and reliability of power sources such as UPS systems, generators, and renewable energy installations.
This rack-mounted load bank combines compact design, precision control, and robust safety features, providing a trusted solution for critical testing applications in both industrial and commercial environments.
| Parameter | Spécification |
|---|---|
| Nominal Voltage | 230V AC |
| Maximum Power Capacity | 6 kW |
| Type de charge | Resistive |
| Load Adjustment | Step load control with digital interface |
| Méthode de refroidissement | Air-cooled (efficient thermal management) |
| Rack Compatibility | Standard 19-inch rack-mounted design |
| Caractéristiques de sécurité | Over-temperature, over-current protection |
| Display | Digital meter for voltage, current, and power readings |
| Compliance | CE, ISO, and other international safety and performance standards |
| Operating Environment | 0–40°C, 20–80% RH non-condensing |
Precision Load Simulation
The AC230V-6KW-R accurately converts electrical energy into heat through resistive elements, providing stable and repeatable load conditions for testing electrical systems. This allows engineers to measure system performance under realistic operating conditions, ensuring equipment reliability and efficiency.
Rack-Mountable Compact Design
Its 19-inch rack form factor allows for seamless integration into existing data center racks or test labs, saving space and simplifying installation.
Digital Control and Monitoring
Équipé d'undigital interface, this load bank provides precise control over load increments, along with real-time monitoring of voltage, current, and power consumption. This ensures accurate testing and detailed data recording.
Robust Safety Features
Safety is paramount. Over-temperature and over-current protections prevent system damage during high-load testing. This ensures both the load bank and the connected equipment remain protected.
High Reliability and Durability
Manufactured with industrial-grade components and designed for continuous operation, this device ensures long-term reliability, even under frequent or high-demand testing scenarios.
The GROADA AC230V-6KW-R is widely used across industries where power reliability is critical:
Data Center Load Testing: Simulate server racks and IT equipment to verify cooling efficiency, electrical distribution, and system stability.
UPS and Generator Testing: Validate the performance of uninterruptible power supplies and backup generators under full load conditions.
Systèmes d'énergie renouvelable: Test inverters, battery storage systems, and hybrid energy setups to ensure optimal energy conversion and system reliability.
Power Distribution System Assessment: Measure the capacity, stability, and efficiency of electrical distribution networks under realistic operating conditions.
Industrial Equipment Testing: Evaluate the load tolerance and thermal behavior of critical machinery and electrical components.
The global load bank market is projected to experience steady growth, driven by the expanding data center industry, rising adoption of UPS and backup power systems, and increasing integration of renewable energy solutions. Air-cooled rack-mounted load banks, like the AC230V-6KW-R, are particularly favored for efficient heat dissipation, compact installation, and precise load testing.
Recent industry reports indicate that data centers alone account for a significant portion of load bank demand, highlighting the importance of reliable testing solutions to ensure uptime, prevent downtime, and safeguard mission-critical equipment.
High Precision and Accuracy: Provides realistic load simulation for comprehensive testing.
Space-Saving Design: Rack-mountable form factor for streamlined installation.
User-Friendly Operation: Digital interface enables easy load adjustments and monitoring.
Advanced Safety Protections: Minimizes risk to personnel and equipment.
Global Compliance: Manufactured to international standards, ensuring reliability and performance.
Long-Term Durability: Industrial-grade components designed for continuous, high-demand usage.
LeGROADA AC230V-6KW-R Rack-Mounted Load Bank is a professional-grade solution for engineers, technicians, and data center operators who require precise, reliable, and safe load testing. Its combination of compact design, advanced monitoring, and robust safety features makes it an indispensable tool in modern power management, UPS testing, and electrical system verification.
With the GROADA AC230V-6KW-R, you can ensure your systems perform optimally under real-world conditions, reduce downtime, and maintain operational excellence in critical infrastructure environments.