Banque de charge d'onduleur GROADA-AC380V-50KW-R/RCD
The GROADA AC380V-50KW-R/RCD inverter test load bank is a high-performance testing device specifical...
| Modèle | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| Puissance nominale | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Courant d'entrée | 0 à 22A | 0 à 45A | 0 à 45A | 0 à 90A | 0 à 45A | 0 à 300A | 0 à 450A | 0 à 600A | 0 à 750A |
| Taille (largeur * profondeur * hauteur mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Poids | 50 kg | 80 kg | 100 kilogrammes | 130 kg | 200 kg | 300 kg | 350kg | 450 kg | 550kg |
| Tension d'entrée | AC220 / 230V | AC380 / 400V | |||||||
| Autre tension d'entrée peut être personnalisée selon les exigences | |||||||||
| Chargement minimum | 100 watts | 100 watts | 100 watts | 100 watts | 100 watts | 1 kilowatt | 1 kilowatt | 1 kilowatt | 1 kilowatt |
| Autre puissance de charge minimale peut être personnalisée selon les exigences | |||||||||
| Précision globale | 3% (autres exigences de précision peuvent être personnalisées selon les exigences) | ||||||||
| facteur de puissance | PF = 0,6 ~ 1,0 | ||||||||
| coefficient de pic | 2 à 3 | ||||||||
| Mode de commande | Ordinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin) | ||||||||
| Interface à distance | RS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences) | ||||||||
| Fonction de protection | Protection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant) | ||||||||
| Alimentation électrique de travail | AC220V | AC220V / AC380V | |||||||
| Précision de l'affichage | Niveau 0,5 (autre précision explicite peut être personnalisée selon les exigences) | ||||||||
| Paramètres d'affichage | Voltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences) | ||||||||
| Froid façon sûre | Entrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences) | ||||||||
| Niveau de protection | IP20 (autre niveau de protection peut être personnalisé selon les exigences) | ||||||||
| Couleur d'apparence | RAL7035 (autres couleurs peuvent être personnalisées selon les exigences) | ||||||||
| Température de travail | -10 ℃ ~ 55 ℃ | ||||||||
| Humidité relative | ≤95% RH | ||||||||
| Altitude | ≤ 2500 m | ||||||||
La banque de charge d'onduleur GROADA AC600V 25 kW est une solution d'essai spécialement conçue pour les fabricants d'onduleurs, les laboratoires et les ingénieurs en électronique de puissance qui nécessitent une validation précise, répétable et sûre des performances. Conçu pour les applications modernes d'énergie renouvelable et de stockage d'énergie, il fournit un environnement contrôlé pour simuler des conditions de fonctionnement réelles et s'assurer que les onduleurs répondent à des normes de fiabilité et d'efficacité rigoureuses.
Alors que les systèmes solaires, les batteries et les microréseaux continuent de se développer, la fiabilité des onduleurs est devenue plus critique que jamais. Une banque de charge professionnelle est essentielle pour vérifier les revendications de conception, réduire le risque de défaillance et renforcer la confiance des clients.
Une banque de charge d'onduleur est un dispositif de précision qui applique une charge électrique à un onduleur en cours d'essai de manière sûre et contrôlée. Contrairement aux essais de terrain passifs, qui exposent l'équipement à des conditions imprévisibles, une banque de charge fournit des charges stables et réglables, permettant aux ingénieurs de :
Mesurer l'efficacité de conversion à travers différents niveaux de charge
Analyser le comportement thermique de l'inverseur en fonctionnement continu
Valider les caractéristiques de surcourant, de surtension et de protection
Performance de l'inverseur d'essai à la fois avec des charges résistives et réactives
Confirm grid-compliance functions such as anti-islanding and synchronization
This makes the GROADA AC600V 25 kW Load Bank an indispensable tool for inverter R&D, production quality assurance, and third-party certification.
600 V DC input and 25 kW power capacity — suitable for medium-scale PV and ESS inverters
Programmable load profiles — supports stepped, gradual, or dynamic load changes
Resistive, reactive, and inductive test modes — replicates real-world load conditions
Energy regenerative design — reduces wasted energy by feeding it back to the grid
High measurement accuracy — captures voltage, current, frequency, THD, and power factor with precision
Comprehensive protection — includes overcurrent, overvoltage, and thermal safeguards
Modular scalability — units can be combined for higher test power requirements
Industrial-grade reliability — robust cooling, durable construction, and long service life
By gradually stepping through load levels (10%, 20%, 50%, 100%), engineers can generate inverter efficiency curves and quantify power losses. This is essential for meeting regulatory requirements and optimizing design.
Sustained full-power operation simulates demanding field conditions. Engineers can verify cooling system performance, detect hot spots, and assess component aging over time.
Real electrical networks rarely operate with pure resistive loads. The ability to test with inductive or capacitive elements ensures accurate validation of power factor correction, stability, and reactive power handling.
Step loads, sudden drops, or rapid fluctuations test the robustness of inverter control loops. Load banks can uncover hidden weaknesses in firmware or protection systems that would otherwise appear only in the field.
Grid codes worldwide require inverters to handle abnormal conditions such as voltage dips, frequency shifts, or anti-islanding detection. A load bank allows safe simulation of these events to prove compliance with IEC, IEEE, and UL standards.
Solar Photovoltaic Inverters — verifying efficiency, MPP tracking, and safety under variable sunlight conditions
Energy Storage Systems (ESS) — testing bidirectional inverters and charge/discharge cycles
Microgrids and Hybrid Power Systems — ensuring reliable power sharing and seamless transitions
R&D Laboratories — supporting prototype evaluation and academic research in power electronics
Manufacturing QA — providing repeatable end-of-line testing before product shipment
Trusted Accuracy – Designed with precision instrumentation for reliable test results.
Energy Savings – Regenerative design minimizes waste and reduces operational costs.
Operator Safety – Integrated protections and emergency shutoffs ensure safe operation.
Flexibility – Adaptable to multiple inverter types, from residential PV to industrial storage.
Future-Proof – Modular capacity supports expansion as test demands grow.
The GROADA 25 kW Inverter Load Bank is engineered to support compliance testing with major global standards, including:
IEC 62116 – Test procedure of islanding prevention measures for grid-connected PV inverters
IEC 61000 – Electromagnetic compatibility requirements
IEEE 1547 – Standard for interconnection and interoperability of distributed resources
UL 1741 – Inverters, converters, and controllers for use in distributed energy resources
Meeting these standards is essential for manufacturers aiming to enter international markets with certified products.
GROADA specializes in advanced load bank solutions for the renewable energy and power electronics industries. Our engineering team brings years of field experience and technical expertise, ensuring products that combine innovation, durability, and cost efficiency.
By partnering with GROADA, customers gain more than equipment — they gain a trusted testing partner committed to quality, reliability, and global support.
The GROADA AC600V 25 kW Inverter Load Bank empowers inverter developers, manufacturers, and testing laboratories with a reliable, precise, and efficient tool for performance validation. From efficiency mapping to grid-compliance testing, it delivers the insights needed to design robust, safe, and market-ready inverters.
Investing in a professional load bank is not just about compliance — it is about ensuring long-term reliability, customer satisfaction, and competitive advantage in the fast-growing renewable energy sector.