GROADA-AC220V-5KW-R banque de charge AC de type rack
GROADA-AC220V-5KW-R Rack Type AC Load Box_Shenzhen Guangluda Electronics Co., Ltd. is a high-tech en...
| Modèle | AC220V-6KW-R | AC380Le V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Puissance nominale | 0 à 6KW | 0-30KW | 0 à 60KW | 0 à 100KW | 0-200KW | 0-400KW | 0-500KW | 0 à 1000KW |
| Taille (largeur * profondeur * hauteur mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Poids | 25 kg | 80 kg | 130 kg | 180kg | 250 kg | 550kg | 650kg | 1100kg |
| Courant d'entrée | 0 à 30A | 0 à 45A | 0 à 90A | 0 à 150A | 0 à 300A | 0 à 600A | 0 à 750A | 0 à 1500A |
| Chargement minimum | 100 watts | 100 watts | 500W | 1 kilowatt | 1 kilowatt | 5 kilowatts | 10 kilowatts | 50 kilowatts |
| Autre puissance de charge minimale peut être personnalisée selon les exigences | ||||||||
| Tension d'entrée | AC220 / 230V | AC380 / 400V | ||||||
| Autre tension d'entrée peut être personnalisée selon les exigences | ||||||||
| Puissance | PF = 1,0 | |||||||
| Précision globale | 3% (autres exigences de précision peuvent être personnalisées selon les exigences) | |||||||
| Mode de commande | Ordinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin) | |||||||
| Interface à distance | RS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences) | |||||||
| Fonction de protection | Protection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant) | |||||||
| Alimentation électrique de travail | AC220V | AC220V / 380V | AC380V | |||||
| Précision de l'affichage | niveau 0,5 (autre précision explicite peut être personnalisée selon les exigences | |||||||
| Paramètres d'affichage | Voltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences) | |||||||
| Froid façon sûre | En avant et en dehors | Entrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences) | ||||||
| Niveau de protection | IP20 (autre niveau de protection peut être personnalisé selon les exigences) | |||||||
| Couleur d'apparence | RAL7035 (autres couleurs peuvent être personnalisées selon les exigences) | |||||||
| Température de travail | -10 ℃ ~ 55 ℃ | |||||||
| Humidité relative | ≤95% RH | |||||||
| Altitude | ≤ 2500 m | |||||||
Precision Load Testing for Data Centers and Critical Power Systems
LeGROADA AC230V-6.6KW-R Rack-Mounted Load Bank is engineered for accurate and reliable simulation of electrical loads in data centers, server rooms, and industrial power systems. Designed to integrate seamlessly into a standard 19-inch rack, this compact yet powerful load bank allows engineers and technicians to test, commission, and maintain critical power infrastructure with confidence.
By converting electrical energy into controlled heat via precision resistive elements, it provides a realistic representation of operational loads, ensuring that power distribution units (PDUs), uninterruptible power supplies (UPS), and other electrical systems perform reliably under real-world conditions.
Capacité de puissance: 6.6 kW at 230V AC, suitable for medium-sized server racks and industrial systems.
Étapes de charge réglables: Load increments of 0.5 kW for precise testing of varying electrical conditions.
Facteur de puissance: Unity (PF=1), providing realistic resistive load simulation.
Control Options: Local manual control and remote operation via PC software for flexible testing scenarios.
Cooling System: High-efficiency integrated fans ensure safe dissipation of heat during continuous operation.
Safety Protections: Equipped with over-temperature and over-current protection to safeguard both equipment and operators.
Compact Design: 19-inch rack-mounted form factor maximizes space efficiency in server rooms and data centers.
The AC230V-6.6KW-R load bank is versatile and suitable for a wide range of power system testing scenarios:
Data Center Commissioning: Test the performance and reliability of PDUs, UPS systems, and power distribution networks before going live.
Routine Maintenance: Periodically validate backup power and emergency systems to prevent unexpected downtime.
Thermal Management Testing: Assess cooling efficiency and airflow patterns by simulating realistic heat loads within racks.
Equipment Compatibility Verification: Ensure new servers, UPS modules, or power systems operate safely within the existing infrastructure.
Training and Demonstration: Ideal for educational institutions or training centers to demonstrate load bank operations and power system behavior.
| Parameter | Spécification |
|---|---|
| Puissance nominale | 6.6 kW |
| Tension d'entrée | 230V AC |
| Load Adjustment Step | 0.5 kW |
| Facteur de puissance | 1.0 (Resistive Load) |
| refroidissement | Integrated fans |
| Control Options | Manual (local), Remote (PC) |
| Protection | Over-temperature, Over-current |
| Rack Size | 19-inch standard |
| Operating Environment | 0–40°C, 5–95% RH (non-condensing) |
The GROADA AC230V-6.6KW-R is designed to meet or exceed international industry standards:
IEEE 1547: Interconnection of distributed resources with electric power systems.
IEEE 112.3: Standard procedures for testing UPS systems.
NFPA 110: Emergency and standby power systems standards.
ISO 8528: Testing and performance of engine-driven AC generating sets.
Compliance ensures that the load bank delivers reliable, repeatable results while maintaining safety and operational integrity.
Enhanced Reliability: Ensure continuous power availability by detecting potential system weaknesses before they cause failure.
Cost Efficiency: Minimize costly downtime and prevent equipment damage through proactive load testing.
Flexible Operation: Modular design and precise load steps allow for scalable testing scenarios.
Interface conviviale: Simple, intuitive controls reduce the learning curve and improve operational efficiency.
Comprehensive Validation: Simulates real-world operating conditions for accurate thermal, electrical, and performance testing.
Trusted in data centers, industrial facilities, and power testing laboratories worldwide.
Conçu pourprecision, safety, and reliability, with features aligned to professional engineering standards.
Space-saving rack design allows seamless integration into existing IT or industrial environments.
Backed by technical support and industry expertise to ensure successful deployment and operation.
LeGROADA AC230V-6.6KW-R Rack-Mounted Load Bank is an essential tool for any professional managing critical power systems. Its high precision, compliance with international standards, and versatile applications make it an ideal choice for commissioning, maintenance, and testing of data center and industrial electrical systems.
Investing in a GROADA load bank ensures operational reliability, enhanced safety, and optimized system performance, giving engineers and operators confidence in the performance of their power infrastructure.