Banque de charge RCD

GROADA-AC120V-5KW-RCD Banque de charge Fabricant

★★★★★
Produits principaux :
  • Banque de charge AC : R / RL / RLC / RCD
  • Banque de charge DC : DC5V - 2000V, 0A - 5000A


ModèleAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V - 30KW-RCDAC380V - 50KW-RCDAC380V - 60KW-RCDAC380V - 100KW-RCDAC380V - 200KW-RCD
Puissance nominaleR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Courant d'entrée0 à 22A0 à 45A0 à 45A0 à 90A0 à 45A0 à 300A0 à 450A0 à 600A0 à 750A
Taille (largeur * profondeur * hauteur mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Poids50 kg80 kg100 kilogrammes130 kg200 kg300 kg350kg450 kg550kg
Tension d'entréeAC220 / 230VAC380 / 400V
Autre tension d'entrée peut être personnalisée selon les exigences
Chargement minimum100 watts100 watts100 watts100 watts100 watts1 kilowatt1 kilowatt1 kilowatt1 kilowatt
Autre puissance de charge minimale peut être personnalisée selon les exigences
Précision globale3% (autres exigences de précision peuvent être personnalisées selon les exigences)
facteur de puissancePF = 0,6 ~ 1,0
coefficient de pic2 à 3
Mode de commandeOrdinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin)
Interface à distanceRS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences)
Fonction de protectionProtection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant)
Alimentation électrique de travailAC220VAC220V / AC380V
Précision de l'affichageNiveau 0,5 (autre précision explicite peut être personnalisée selon les exigences)
Paramètres d'affichageVoltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences)
Froid façon sûreEntrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences)
Niveau de protectionIP20 (autre niveau de protection peut être personnalisé selon les exigences)
Couleur d'apparenceRAL7035 (autres couleurs peuvent être personnalisées selon les exigences)
Température de travail-10 ℃ ~ 55 ℃
Humidité relative ≤95% RH
Altitude ≤ 2500 m



GROADA AC120V-5KW RCD Load Bank – Advanced Nonlinear Load Testing Solution


Vue d'ensemble

LeGROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate charges électriques non linéaires, offering reliable performance validation for power systems. Perfect for applications such as UPS systems, data centers, telecommunications networks, and industrial power setups, this load bank ensures power sources can handle complex reactive loads safely and efficiently.

By accurately mimicking real-world power demand conditions, it enables engineers to assess system stability, efficiency, and resilience before deployment.


Caractéristiques principales

  • Puissance nominale: 5 kW

  • Voltage Compatibility: AC 120V

  • Type de charge: Nonlinear RCD (Resistive-Capacitive-Dynamic)

  • Load Adjustment: Stepwise incremental load control for precise testing

  • Système de refroidissement: High-efficiency forced-air cooling to maintain optimal operation

  • Control Interface: Intuitive manual control panel with optional remote operation

  • Safety Protections: Overload, over-temperature, and short-circuit safeguards

  • Compliance: Designed to meet international electrical testing standards


Industry Applications

centres de données

Validate UPS and generator performance under dynamic and nonlinear load conditions to prevent downtime and maintain uninterrupted service.

Télécommunications

Ensure reliable power delivery for critical communication systems, supporting continuous network operation.

Systèmes d'énergie renouvelable

Test inverters and energy storage devices under fluctuating load conditions, confirming operational stability.

Industrial & Manufacturing

Simulate heavy machinery and production equipment load profiles, verifying power supply adequacy and system resilience.


Market Insights

Leglobal load bank market is growing rapidly, driven by the increasing complexity of power systems and the rising need for reliable energy infrastructure. Forecasts predict market expansion from USD 288 million in 2024 to over USD 387 million by 2032, emphasizing the importance of high-quality testing devices like the GROADA AC120V-5KW RCD Load Bank.

This growth underscores a broader industry trend: increasing demand for precision load testing equipment to optimize system performance, improve energy efficiency, and mitigate risk in critical infrastructure.


Why Choose GROADA AC120V-5KW RCD Load Bank?

  • High Accuracy: Simulates real-world nonlinear loads to provide precise performance data.

  • Versatile Application: Suitable for UPS, telecom, renewable energy, and industrial systems.

  • Reliability: Constructed with premium components for long-lasting operation.

  • Ease of Operation: Simple, safe controls with comprehensive protective mechanisms.


Conclusion

Investing in the GROADA AC120V-5KW RCD Load Bank ensures that your power systems are rigorously tested, resilient, and ready for complex operational scenarios. Its combination of precision, safety, and versatility makes it a critical tool for engineers and facility managers aiming to enhance power reliability and prevent costly downtime.