GROADA-AC220V-12KW-R Banque de charge résistive
The GROADA AC220V 12KW Resistive Load Bank is engineered for rigorous testing of AC power sources, i...
| Modèle | AC220V-6KW-R | AC380Le V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Puissance nominale | 0 à 6KW | 0-30KW | 0 à 60KW | 0 à 100KW | 0-200KW | 0-400KW | 0-500KW | 0 à 1000KW |
| Taille (largeur * profondeur * hauteur mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Poids | 25 kg | 80 kg | 130 kg | 180kg | 250 kg | 550kg | 650kg | 1100kg |
| Courant d'entrée | 0 à 30A | 0 à 45A | 0 à 90A | 0 à 150A | 0 à 300A | 0 à 600A | 0 à 750A | 0 à 1500A |
| Chargement minimum | 100 watts | 100 watts | 500W | 1 kilowatt | 1 kilowatt | 5 kilowatts | 10 kilowatts | 50 kilowatts |
| Autre puissance de charge minimale peut être personnalisée selon les exigences | ||||||||
| Tension d'entrée | AC220 / 230V | AC380 / 400V | ||||||
| Autre tension d'entrée peut être personnalisée selon les exigences | ||||||||
| Puissance | PF = 1,0 | |||||||
| Précision globale | 3% (autres exigences de précision peuvent être personnalisées selon les exigences) | |||||||
| Mode de commande | Ordinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin) | |||||||
| Interface à distance | RS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences) | |||||||
| Fonction de protection | Protection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant) | |||||||
| Alimentation électrique de travail | AC220V | AC220V / 380V | AC380V | |||||
| Précision de l'affichage | niveau 0,5 (autre précision explicite peut être personnalisée selon les exigences | |||||||
| Paramètres d'affichage | Voltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences) | |||||||
| Froid façon sûre | En avant et en dehors | Entrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences) | ||||||
| Niveau de protection | IP20 (autre niveau de protection peut être personnalisé selon les exigences) | |||||||
| Couleur d'apparence | RAL7035 (autres couleurs peuvent être personnalisées selon les exigences) | |||||||
| Température de travail | -10 ℃ ~ 55 ℃ | |||||||
| Humidité relative | ≤95% RH | |||||||
| Altitude | ≤ 2500 m | |||||||
LeGROADA-AC400V-45KW-R resistive load bank is a high-performance testing solution designed for electrical engineers, facility managers, and power system professionals who require reliable, precise, and safe load testing. With a rated capacity of 45 kW at 400V AC, this load bank simulates real operational conditions for generators, UPS systems, and other critical electrical infrastructure. Its robust design ensures long-term durability, while its advanced control features provide precise load application.
High Power Output: Provides a stable 45 kW resistive load, suitable for full-load testing of medium-scale generators and UPS systems.
Contrôle de charge précis: Allows incremental adjustments for fine-tuned testing, ensuring accurate simulation of real operating conditions.
Construction durable: Built with premium-grade materials to withstand heavy-duty industrial environments.
Safety-Centric Design: Equipped with overload protection, thermal protection, and emergency stop functions, complying with international safety standards.
Versatile Application: Ideal for generator commissioning, routine maintenance, emergency preparedness drills, and UPS verification.
Test du générateur
Assess generator performance under maximum load to guarantee efficiency and reliability during critical operations.
UPS Load Verification
Validate UPS system performance to ensure continuous power delivery during outages.
Maintenance & Diagnostics
Perform scheduled load testing to identify potential failures, optimize performance, and extend equipment lifespan.
Emergency Preparedness
Simulate power outages and evaluate system response under controlled, realistic conditions.
The GROADA-AC400V-45KW-R meets rigorous international standards to ensure reliability, safety, and operational excellence:
IEEE 112 – AC machine performance testing
IEEE 1547 – Interconnection of distributed energy resources
NFPA 110 – Emergency and standby power systems
Adherence to these standards guarantees accurate, safe, and repeatable testing, reinforcing trust in system reliability.
| Parameter | Détails |
|---|---|
| Modèle | GROADA-AC400V-45KW-R |
| Puissance nominale | 45 kW |
| Tension d'entrée | 400V AC |
| Phase | Three-phase |
| Méthode de refroidissement | Forced air |
| Control Type | Local manual control panel |
| Caractéristiques de sécurité | Overload protection, thermal cutoff, emergency stop |
| Dimensions | [Specify dimensions] |
| Poids | [Specify weight] |
| Certifications | [Specify certifications] |
GROADA is a trusted global provider of load testing solutions, committed to delivering high-quality, reliable, and efficient equipment. Our products are engineered for precision, durability, and safety, helping engineers and facilities maintain uninterrupted, optimized power operations. Choosing GROADA ensures peace of mind, operational excellence, and adherence to the highest industry standards.
Courriel: groada@163.com
Phone: +86 755 2333 9096
Adresse: Shenzhen, Guangdong, China