Banque de charge RLC

GROADA-AC800V-851KW-RLC Banque de charge Fabricant

★★★★★
Produits principaux :
  • Banque de charge AC : R / RL / RLC / RCD
  • Banque de charge DC : DC5V - 2000V, 0A - 5000A


ModèleAC220V-10KVA-RLCAC380V-30KVA-RLCAC380V-60KVA-RLCAC380V-100KVA-RLCAC380V-200KVA-RLCAC380V-300KVA-RLC
Puissance nominaleRLC = 10KVARLC = 30KVARLC = 60KVARLC = 100KVARLC = 200KVARLC = 300KVA
R = 10KW; L = 10KVA
C = 10KVA
R = 30KW; L = 30KVA;
C = 30KVA
R = 60KW; L = 60KVA;
C = 60KVA
R = 100KW; L = 100KVA;
C = 100KVA
R = 200KW; L = 200KVA;
C = 200KVA
R = 300KW; L = 300KVA;
C = 300KVA
Autre puissance peut être personnalisée selon les exigences
Taille (largeur * profondeur * hauteur mm)500*750*1400600*850*15001000*1100*15001100*1600*15001500*1800*18002000*2000*2000
Poids120 kg380kg580kg880 kg1500 kg2500kg
Tension d'entréeAC220 / 230VAC380 / 400V
Autre tension d'entrée peut être personnalisée selon les exigences
Courant d'entrée0 à 45A0 à 45A0 à 90A0 à 150A0 à 300A0 à 450A
Chargement minimumR = 100W; L = 100VA;
C = 100VA
R = 100W; L = 100VA;
C = 100VA
R = 100W; L = 100VA;
C = 100VA
R = 100W; L = 100VA;
C = 100VA
R = 1KW; L = 1KVA;
C = 1KVA
R = 1KW; L = 1KVA;
C = 1KVA
Autre puissance de charge minimale peut être personnalisée selon les exigences
facteur de puissancePF = 0,1 ~ 1,0 (autre facteur de puissance peut être personnalisé selon les exigences)
Précision globale3% (autres exigences de précision peuvent être personnalisées selon les exigences)
Mode de commandeOrdinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin)
Interface à distanceRS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences)
Fonction de protectionProtection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant)
Alimentation électrique de travailAC220VAC220V / 380VAC380V
Précision de l'affichageNiveau 0,5 (autre précision explicite peut être personnalisée selon les exigences)
Paramètres d'affichageVoltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences)
Froid façon sûreEntrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences)
Niveau de protectionIP20 (autre niveau de protection peut être personnalisé selon les exigences)
Couleur d'apparenceRAL7035 (autres couleurs peuvent être personnalisées selon les exigences)
Température de travail-10 ℃ ~ 55 ℃
Humidité relative ≤95% RH
Altitude ≤ 2500 m


GROADA AC800V-851KW RLC Three-Phase AC Load Bank: Precision Power Testing for High-Voltage Systems

LeGROADA AC800V-851KW RLC Three-Phase AC Load Bank represents the pinnacle of modern electrical testing solutions, designed to deliver precise, safe, and comprehensive load simulations for high-voltage power systems. Combining résistif (R), inductif (L) et capacitif (C) components, this load bank allows engineers and technicians to replicate real-world electrical conditions, ensuring that generators, UPS systems, and other critical infrastructure operate at peak reliability.


Key Features and Technical Specifications

  • Puissance nominale: 851 kW

  • Operating Voltage: 800V AC, three-phase, 50 Hz

  • Facteur de puissance réglable: 0.1 to 1.0 (lagging and leading)

  • Load Resolution: 10 W for resistive, 10 VAR for inductive, 10 VAR for capacitive components

  • Interface de contrôle: User-friendly local panel with remote monitoring capability

  • Cooling System: High-efficiency forced air cooling

  • Mécanismes de sécurité: Overload protection, temperature alarms, emergency stop

  • Compliance: Manufactured to meet international testing equipment standards


Applications

This versatile RLC load bank is ideal for multiple industries:

  • Power Generation: Validate and stress-test generators, transformers, and switchgear.

  • centres de données: Ensure uninterrupted operation of UPS systems and emergency power backups.

  • Industrial Manufacturing: Test motors, large-scale machinery, and heavy-duty equipment.

  • Renewable Energy: Simulate grid conditions for solar, wind, and hybrid energy systems.

  • Télécommunications: Verify rectifiers and backup power solutions under dynamic loads.


Why RLC Load Banks Are Essential

In modern power systems, accurately simulating both active and reactive power is critical. RLC load banks replicate not only resistive loads but also inductive and capacitive effects, giving engineers the ability to evaluate voltage stability, harmonics, and power factor correction. This ensures long-term system reliability and prevents costly downtime.


Insights sur l'industrie

The global load bank market is experiencing robust growth, fueled by the expansion of power infrastructure, the rise of renewable energy, and increasing demand for reliable backup power. According to recent industry data, the market is projected to reach over USD 500 million by 2032, with RLC load banks representing a fast-growing segment due to their ability to mimic complex electrical loads and dynamic system behavior.


Why Choose GROADA?

  • Comprehensive Simulation: Accurately emulate real-world electrical loads for precise system evaluation.

  • High Precision: Advanced load control technology ensures reliable and repeatable test results.

  • Durable Design: Rugged construction designed to withstand industrial environments and long-term use.

  • Global Standard Compliance: Meets international standards, ensuring reliability across diverse markets.


Conclusion:
LeGROADA AC800V-851KW RLC Three-Phase AC Load Bank is a crucial tool for engineers, data centers, industrial facilities, and power generation companies who demand high-precision, reliable, and safe electrical testing solutions. With its advanced RLC configuration, it not only supports routine load testing but also prepares your infrastructure for real-world operational challenges.

Notre produit