GROADA-AC220V-15KW-RLC Banque de charge Fabricant
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| Modèle | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Puissance nominale | RLC = 10KVA | RLC = 30KVA | RLC = 60KVA | RLC = 100KVA | RLC = 200KVA | RLC = 300KVA |
| R = 10KW; L = 10KVA C = 10KVA | R = 30KW; L = 30KVA; C = 30KVA | R = 60KW; L = 60KVA; C = 60KVA | R = 100KW; L = 100KVA; C = 100KVA | R = 200KW; L = 200KVA; C = 200KVA | R = 300KW; L = 300KVA; C = 300KVA | |
| Autre puissance peut être personnalisée selon les exigences | ||||||
| Taille (largeur * profondeur * hauteur mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Poids | 120 kg | 380kg | 580kg | 880 kg | 1500 kg | 2500kg |
| Tension d'entrée | AC220 / 230V | AC380 / 400V | ||||
| Autre tension d'entrée peut être personnalisée selon les exigences | ||||||
| Courant d'entrée | 0 à 45A | 0 à 45A | 0 à 90A | 0 à 150A | 0 à 300A | 0 à 450A |
| Chargement minimum | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 1KW; L = 1KVA; C = 1KVA | R = 1KW; L = 1KVA; C = 1KVA |
| Autre puissance de charge minimale peut être personnalisée selon les exigences | ||||||
| facteur de puissance | PF = 0,1 ~ 1,0 (autre facteur de puissance peut être personnalisé selon les exigences) | |||||
| Précision globale | 3% (autres exigences de précision peuvent être personnalisées selon les exigences) | |||||
| Mode de commande | Ordinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin) | |||||
| Interface à distance | RS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences) | |||||
| Fonction de protection | Protection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant) | |||||
| Alimentation électrique de travail | AC220V | AC220V / 380V | AC380V | |||
| Précision de l'affichage | Niveau 0,5 (autre précision explicite peut être personnalisée selon les exigences) | |||||
| Paramètres d'affichage | Voltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences) | |||||
| Froid façon sûre | Entrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences) | |||||
| Niveau de protection | IP20 (autre niveau de protection peut être personnalisé selon les exigences) | |||||
| Couleur d'apparence | RAL7035 (autres couleurs peuvent être personnalisées selon les exigences) | |||||
| Température de travail | -10 ℃ ~ 55 ℃ | |||||
| Humidité relative | ≤95% RH | |||||
| Altitude | ≤ 2500 m | |||||
LeGROADA AC800V-851KW RLC Three-Phase AC Load Bank represents the pinnacle of modern electrical testing solutions, designed to deliver precise, safe, and comprehensive load simulations for high-voltage power systems. Combining résistif (R), inductif (L) et capacitif (C) components, this load bank allows engineers and technicians to replicate real-world electrical conditions, ensuring that generators, UPS systems, and other critical infrastructure operate at peak reliability.
Puissance nominale: 851 kW
Operating Voltage: 800V AC, three-phase, 50 Hz
Facteur de puissance réglable: 0.1 to 1.0 (lagging and leading)
Load Resolution: 10 W for resistive, 10 VAR for inductive, 10 VAR for capacitive components
Interface de contrôle: User-friendly local panel with remote monitoring capability
Cooling System: High-efficiency forced air cooling
Mécanismes de sécurité: Overload protection, temperature alarms, emergency stop
Compliance: Manufactured to meet international testing equipment standards
This versatile RLC load bank is ideal for multiple industries:
Power Generation: Validate and stress-test generators, transformers, and switchgear.
centres de données: Ensure uninterrupted operation of UPS systems and emergency power backups.
Industrial Manufacturing: Test motors, large-scale machinery, and heavy-duty equipment.
Renewable Energy: Simulate grid conditions for solar, wind, and hybrid energy systems.
Télécommunications: Verify rectifiers and backup power solutions under dynamic loads.
In modern power systems, accurately simulating both active and reactive power is critical. RLC load banks replicate not only resistive loads but also inductive and capacitive effects, giving engineers the ability to evaluate voltage stability, harmonics, and power factor correction. This ensures long-term system reliability and prevents costly downtime.
The global load bank market is experiencing robust growth, fueled by the expansion of power infrastructure, the rise of renewable energy, and increasing demand for reliable backup power. According to recent industry data, the market is projected to reach over USD 500 million by 2032, with RLC load banks representing a fast-growing segment due to their ability to mimic complex electrical loads and dynamic system behavior.
Comprehensive Simulation: Accurately emulate real-world electrical loads for precise system evaluation.
High Precision: Advanced load control technology ensures reliable and repeatable test results.
Durable Design: Rugged construction designed to withstand industrial environments and long-term use.
Global Standard Compliance: Meets international standards, ensuring reliability across diverse markets.
Conclusion:
LeGROADA AC800V-851KW RLC Three-Phase AC Load Bank is a crucial tool for engineers, data centers, industrial facilities, and power generation companies who demand high-precision, reliable, and safe electrical testing solutions. With its advanced RLC configuration, it not only supports routine load testing but also prepares your infrastructure for real-world operational challenges.