GROADA-DC60V-270A-R Laadbankfabriek
型号GROADA-DC48V-RGROADA-DC60V-RGROADA-DC110V-RGROADA-DC220V-RGROADA-DC500V-RGROADA-DC750V-RGROADA-DC1...
| Model | Groada-DC48V-R | Groada-DC60V-R | Groada-DC110V-R | Groada-DC220V-R | Groada-DC500V-R | Groada-DC750V-R | Groada-DC1000V-R |
| Nominale huidige | 0 tot 5000A | ||||||
| Ingangsspanning | 0 ~ 1500V | ||||||
| Minimale lading | 0,1 A | ||||||
| Andere minimale lading kan volgens vereisten worden aangepast | |||||||
| Algemene nauwkeurigheid | 3% (andere nauwkeurigheidsvereisten kunnen volgens vereisten worden aangepast) | ||||||
| Controle modus | Lokale handmatige/externe gastcomputer (lokale handmatige besturingsmodus: schakelaar/knop/aanraakscherm drieweg optioneel, andere methoden kunnen worden aangepast zoals vereist) | ||||||
| Interface op afstand | RS232/RS485/USB/RJ45/CAN/GPIB (andere interfacemodies kunnen volgens vereisten worden aangepast) | ||||||
| Beschermingsfunctie | Bescherming tegen noodstop, bescherming tegen overtemperatuur, bescherming tegen ventilatorbelasting, bescherming tegen aarding (selecteer bescherming tegen overspanning, bescherming tegen overstroom, bescherming tegen kortsluiting, overbelasting van de ventilator, onvoldoende luchtvolume) | ||||||
| Werkende voeding | GROADA / AC380V | ||||||
| Vertoningsnauwkeurigheid | 0,5 niveau (andere expliciete precisie kan volgens vereisten worden aangepast) | ||||||
| Weergave parameters | Spanning, stroom, vermogen, enz. | ||||||
| Koude zekere manier | Zijluchtingang en bovenluchtuitlaat (andere luchtuitlaatmethoden kunnen volgens vereisten worden aangepast) | ||||||
| Beschermingsniveau | IP20 (andere beschermingsniveau kan volgens vereisten worden aangepast) | ||||||
| Kleur van uiterlijk | RAL7035 (andere kleuren kunnen volgens vereisten worden aangepast) | ||||||
| Werktemperatuur | -10 ℃ ~ 55 ℃ | ||||||
| Relatieve vochtigheid | ≤95%RH | ||||||
| Hoogte | ≤ 2500 m | ||||||
DeGROADA-DC60V-270A-R DC laadbankis een precisie-ontworpen resistief belastingstestsysteem ontworpen om gelijkstroombronnen zoals batterijen, gelijkrichters en energieopslagsystemen te verifiëren en te valideren. Gebouwd met uitzonderlijke technische nauwkeurigheid en robuuste constructie, stelt het professionals in staat om betrouwbare ontladings-, prestaties- en uithoudingstests uit te voeren onder gecontroleerde omstandigheden.
Aangezien moderne industrieën steeds meer vertrouwen op gelijkstroom - van telecomnetwerken en datacenters tot hernieuwbare energiesystemen - is de behoefte aan betrouwbare en nauwkeurige belastingstestapparatuur van het grootste belang. DeGroada-DC60V-270A-Rbiedt ingenieurs een krachtig testplatform dat echte elektrische belastingen nauwkeurig simuleert, waardoor ze volledig vertrouwen hebben in systeembetrouwdheid en prestaties.
Of het nu gaat om inbedrijfstelling, preventief onderhoud of laboratoriumonderzoek, deze laadbank zorgt ervoor dat elke test echte operationele omstandigheden weerspiegelt, waardoor risico's en downtimes worden geminimaliseerd.
| Eigenschap | Beschrijving & Voordeel |
|---|---|
| Voltage & Current Range | DC 60 V, up to 270 A — suitable for a wide range of DC systems and battery configurations. |
| Pure Resistive Load | Offers consistent and predictable current draw, ideal for verifying voltage regulation, current stability, and discharge characteristics. |
| Modular Load Steps | Multiple independently controlled load segments enable flexible and accurate load adjustment. |
| Hoge meetnauwkeurigheid | Integrated precision meters and data acquisition ensure every reading is trustworthy and traceable. |
| Comprehensive Protection | Built-in safeguards for overcurrent, overtemperature, and airflow failure ensure operational safety and equipment protection. |
| Superior Cooling System | Optimized forced-air cooling guarantees stable thermal performance during continuous full-load testing. |
| Durable Industrial Design | Robust enclosure, compact structure, and high-quality materials for long-term reliability and portability. |
Each component of the GROADA DC load bank is engineered to meet international standards and tested rigorously to ensure lasting performance in demanding field and laboratory environments.
The GROADA-DC60V-270A-R load bank serves a broad spectrum of professional applications:
Validate the capacity, efficiency, and health of batteries by simulating real load conditions. Detect internal resistance changes and identify degradation early.
Assess the voltage regulation and dynamic response of DC power systems under various load profiles, ensuring long-term stability.
Guarantee the reliability of critical backup systems. Conduct routine discharge and load tests to prevent power failures in mission-critical environments.
Evaluate lithium-ion or lead-acid storage systems used in solar, microgrid, and hybrid power solutions under realistic operational loads.
Ideal for controlled experiments, performance validation, and product qualification within research facilities and technical laboratories.
GROADA stands as a trusted manufacturer of professional load testing solutions, recognized globally for its expertise and innovation in the power testing field.
With years of design experience, GROADA integrates cutting-edge testing methodologies and field data into every product, ensuring consistent precision and repeatability.
All units are built under stringent quality systems, with optional CE, ISO, and other global certifications available to meet international compliance standards.
From pre-sale consulting to post-sale calibration and maintenance, GROADA offers full technical support to ensure your testing remains accurate over time.
Trusted by clients across telecommunications, power utilities, laboratories, and data centers worldwide, GROADA products are known for reliability and durability in real operating environments.
DeGROADA-DC60V-270A-R DC laadbank is more than just a testing device—it’s an assurance of reliability and technical excellence. By combining precise load control, robust safety mechanisms, and long-term dependability, it empowers engineers and technicians to make data-driven decisions with complete confidence.
Whether you are validating a telecom DC bus, commissioning a solar storage unit, or conducting routine UPS maintenance, the GROADA DC Load Bank delivers the accuracy and stability you need for professional power testing.
Test Smarter. Operate Safer. Trust GROADA.