RCD laadbank

GROADA-AC380V-30KW-RCD Lastbank Fabrikanten

★★★★★
Belangrijkste producten:
  • AC Lastbank: R/RL/RLC/RCD
  • DC Load Bank: DC5V - 2000V, 0A - 5000A


ModelAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V - 30KW-RCDAC380V - 50KW-RCDAC380V - 60KW-RCDAC380V - 100KW-RCDAC380V - 200KW-RCD
Nominale vermogenR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Input stroom0-22A0-45A0-45A0-90A0-45A0-300A0-450A0-600A0-750A
Grootte (breedte * diepte * hoogte mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
gewicht50 kg80 kg100 kg130 kg200 kg300 kg350 kg450 kg550 kg
IngangsspanningAC220 / 230VAC380 / 400V
Andere ingangsspanning kan volgens vereisten worden aangepast
Minimale lading100W100W100W100W100W1kw1kw1kw1kw
Andere minimale laadmacht kan volgens vereisten worden aangepast
Algemene nauwkeurigheid3% (andere nauwkeurigheidsvereisten kunnen volgens vereisten worden aangepast)
vermogensfactorPF = 0,6 ~ 1,0
piekcoëfficiënt2 tot 3
Controle modusLokale handmatige/externe gastcomputer (lokale handmatige besturingsmodus: schakelaar/knop/aanraakscherm drieweg optioneel, andere methoden kunnen worden aangepast zoals vereist)
Interface op afstandRS232/RS485/USB/RJ45/CAN/GPIB (andere interfacemodies kunnen volgens vereisten worden aangepast)
BeschermingsfunctieBescherming tegen noodstop, bescherming tegen overtemperatuur, bescherming tegen ventilatorbelasting, bescherming tegen aarding (selecteer bescherming tegen overspanning, bescherming tegen overstroom, bescherming tegen kortsluiting, overbelasting van de ventilator, onvoldoende luchtvolume)
Werkende voedingAC220VAC220V / AC380V
Vertoningsnauwkeurigheid0,5 niveau (andere expliciete precisie kan volgens vereisten worden aangepast)
Weergave parametersSpanning, stroom, vermogen, frequentie, vermogensfactor, enz. (andere expliciete methoden kunnen volgens vereisten worden aangepast)
Koude zekere manierZijluchtingang en bovenluchtuitlaat (andere luchtuitlaatmethoden kunnen volgens vereisten worden aangepast)
BeschermingsniveauIP20 (andere beschermingsniveau kan volgens vereisten worden aangepast)
Kleur van uiterlijkRAL7035 (andere kleuren kunnen volgens vereisten worden aangepast)
Werktemperatuur-10 ℃ ~ 55 ℃
Relatieve vochtigheid ≤95%RH
Hoogte ≤ 2500 m


GROADA AC380V 30KW RCD Load Bank - Geavanceerde niet-lineaire laadtestingsoplossing

DeGROADA AC380V 30KW RCD Laadbankis een geavanceerde oplossing voor het testen en valideren van moderne energiesystemen. Ontworpen om echte elektrische omstandigheden te repliceren, biedt het nauwkeurige simulatie vanniet-lineaire belastingenHet stelt ingenieurs in staat om de prestaties, efficiëntie en betrouwbaarheid van generatoren, UPS-systemen, omvormers en andere kritieke stroomapparatuur te beoordelen.

Of het nu gaat om industriële activiteiten, datacenters of installaties voor hernieuwbare energie, deze laadbank zorgt ervoor dat uw systemen robuust, veerkrachtig en klaar zijn voor elk elektrisch scenario.


🔧 Productspecificaties

EigenschapSpecificatie
Nominale macht30 kW (weerstand) / 30 kVA (capacitief)
SpanningAC 380V, 3-fase
Frequentie50/60 Hz
Power Factor bereik0,6 – 1,0 (verstelbaar)
Maximale huidigeUp to 576A (3-phase)
LaadtypeResistive-Capacitive (RCD)
VeiligheidsbeschermingOvercurrent, overvoltage, overtemperature, emergency stop

Key Insight: The combination of resistive and capacitive elements allows this load bank to generate non-linear load profiles that closely mimic modern electronic equipment behavior, ensuring realistic testing conditions.


⚙️ Core Features and Advantages

1. Accurate Non-Linear Load Simulation

Modern electrical systems often encounter niet-lineaire belastingen due to electronic devices like computers, servers, and inverters. The RCD load bank replicates these conditions, allowing engineers to evaluate power system performance, including voltage stability, current harmonics, and thermal response under real operating scenarios.

2. Adjustable Power Factor for Comprehensive Testing

Depower factor adjustment range (0.6–1.0) ensures that your equipment can be tested under a variety of load conditions, from capacitive-heavy to predominantly resistive loads. This flexibility is critical for validating UPS, generator, and inverter performance under diverse operational scenarios.

3. High Current Capacity for Industrial Applications

With the ability to handle up to 576A in three-phase configurations, this load bank is suitable for medium to high-capacity power systems. It allows full-load testing without overloading the equipment under test, ensuring reliability and operational safety.

4. Integrated Safety and Reliability Features

Safety is paramount in load testing. The GROADA RCD Load Bank is equipped with:

  • Overcurrent protection to prevent excessive load damage

  • Overvoltage protection to safeguard connected equipment

  • Overtemperature protection for internal heating control

  • Emergency stop for immediate shutdown during unexpected situations

5. User-Friendly Interface and Real-Time Monitoring

The digital display provides continuous monitoring of:

  • Spanning en stroom

  • Real-time power consumption

  • Power factor and load distribution

This ensures precise, data-driven testing with minimal operator error.


📈 Industry Applications

The GROADA AC380V 30KW RCD Load Bank is ideal across multiple sectors:

  • Datacentra: Test UPS and backup generators under realistic, fluctuating load conditions.

  • Telecommunications: Validate the reliability of inverters and backup power for mission-critical networks.

  • Industrial Manufacturing: Confirm generator and electrical system resilience in factories and production facilities.

  • Renewable Energy: Evaluate inverters and hybrid energy systems in solar and wind installations to ensure optimal performance.


🌐 Compliance with International Standards

This load bank aligns with industry standards and best practices, including:

  • het IEEE 1547 – Interconnection and performance of distributed energy resources

  • IEEE 112.3 – Generator testing methods

  • ISO 8528 – Reciprocating internal combustion engine-driven generating sets

Compliance guarantees trustworthy, repeatable testing results for both local and international projects.


💡 Why Choose GROADA AC380V 30KW RCD Load Bank?

  1. Enhanced Testing Accuracy: Realistic simulation of non-linear loads ensures precise system evaluation.

  2. Wide Application Range: Suitable for data centers, industrial sites, telecom networks, and renewable energy projects.

  3. Long-Term Reliability: High-quality components for consistent performance over time.

  4. Operator Safety: Built-in protections and emergency stop mechanisms safeguard users and equipment.

Investing in the GROADA AC380V 30KW RCD Load Bank means preparing your power systems for real-world demands, minimizing downtime, and optimizing operational efficiency.


Onze producten