RL Laadbank

GROADA-AC600V-180KVA-RL Resistieve Inductieve laadbank

★★★★★
Belangrijkste producten:
  • AC Lastbank: R/RL/RLC/RCD
  • DC Load Bank: DC5V - 2000V, 0A - 5000A


ModelAC220V-10KVA-RLhet AC380De V-30KVA-RLhet AC380De V-60KVA-RLhet AC380De V-100KVA-RLhet AC380De V-300KVA-RLhet AC380De V-500KVA-RLhet AC380De V-1000KVA-RL
Nominale vermogenRL = 10KVARL = 30KVARL = 60KVARL = 100KVARL = 300KVARL = 500KVARL = 1000KVA
R = 10KW; L = 6KVAR = 30KW; L = 18KVAR = 60KW; L = 36KVAR = 100KW; L = 60KVAR = 300KW; L = 180KVAR = 500KW; L = 300KVAR = 1000KW; L = 600KVA
Input stroom0-45A0-45A0-90A0-150A0-450A0-750A0-1500A
Grootte (breedte * diepte * hoogte mm)480*600*277480*600*360500*750*1000600*850*1000700*1000*16501100*1400*17001100*1500*1900
gewicht25 kg40 kg80 kg130 kg250 kg550 kg750 kg
Minimale lading100W100W100W500W1kw5 kw10 kw
Andere minimale laadmacht kan volgens vereisten worden aangepast
IngangsspanningAC220 / 230VAC380 / 400V
Andere ingangsspanning kan volgens vereisten worden aangepast
vermogensfactorPF = 0,8/1,0 (andere vermogensfactor kan volgens vereisten worden aangepast)
Algemene nauwkeurigheid3% (andere nauwkeurigheidsvereisten kunnen volgens vereisten worden aangepast)
Controle modusLokale handmatige/externe gastcomputer (lokale handmatige besturingsmodus: schakelaar/knop/aanraakscherm drieweg optioneel, andere methoden kunnen worden aangepast zoals vereist)
Interface op afstandRS232/RS485/USB/RJ45/CAN/GPIB (andere interfacemodies kunnen volgens vereisten worden aangepast)
BeschermingsfunctieBescherming tegen noodstop, bescherming tegen overtemperatuur, bescherming tegen ventilatorbelasting, bescherming tegen aarding (selecteer bescherming tegen overspanning, bescherming tegen overstroom, bescherming tegen kortsluiting, overbelasting van de ventilator, onvoldoende luchtvolume)
Werkende voedingAC220VAC220V / 380VAC380V
Vertoningsnauwkeurigheid0,5 niveau (andere expliciete precisie kan volgens vereisten worden aangepast)
Weergave parametersSpanning, stroom, vermogen, frequentie, vermogensfactor, enz. (andere expliciete methoden kunnen volgens vereisten worden aangepast)
Koude zekere manierZijluchtingang en bovenluchtuitlaat (andere luchtuitlaatmethoden kunnen volgens vereisten worden aangepast)
BeschermingsniveauIP20 (andere beschermingsniveau kan volgens vereisten worden aangepast)
Kleur van uiterlijkRAL7035 (andere kleuren kunnen volgens vereisten worden aangepast)
Werktemperatuur-10 ℃ ~ 55 ℃
Relatieve vochtigheid ≤95%RH
Hoogte ≤ 2500 m



GROADA AC600V 180 kVA RL Resistief-Inductieve Lastbank — Betrouwbare Volledige Spectrum Power Testing

Inleiding & Waardevoorstel

Bij de inbedrijfstelling, het onderhoud of de validatie van missiekritische stroomsystemen hebt u meer nodig dan "alleen maar laden". U hebt precisie, flexibiliteit en vertrouwen nodig onder echte omstandigheden. DeGROADA AC600V 180 kVA RL Resistief-Inductieve Belastingsbanklevert een robuust, veldbewezen platform voor het testen van volledige generatoren / UPS's / stroomsystemen - het combineren van resistieve en inductieve lastelementen in een compacte, modulaire oplossing.

Door zowel echte (resistieve) als reactieve (inductieve) belastingen te simuleren (meestal met een doelvermogensfactor zoals 0,8), helpt deze RL-belastingsbank u de stabiliteit van de systeemspanning, de stroomreactie, het voorbijgaande gedrag en de volledige generator-naamplaatcapaciteit te valideren - allemaal vóór de daadwerkelijke inzet.


Belangrijkste kenmerken & Technische hoogtepunten

1. Dubbele-moduslaad (Resistief + Inductief)

  • Ondersteunt resistieve lading (voor echt vermogen) en inductieve lading (voor achterblijvend reactief vermogen), waardoor realistischere spanningstests van het vermogenssysteem mogelijk zijn.

  • Kan testen leveren op0,8 vermogensfactordoor de combinatie van resistieve en inductieve secties, een algemeen aanvaarde standaard voor generator acceptatietesten.

  • Biedt flexibele werking: alleen resistieve modus, alleen inductieve modus of gecombineerde RL-modus als vereist.

2. Elektrische & Prestatiespecs

  • Beoordeeld voor600 V AC ingang, driefase (andere spanningen beschikbaar op aanvraag).

  • Nominale capaciteit:180 kVADit betekent meestal ~144 kW resistief + ~108 kVAR inductief (afhankelijk van de configuratie).

  • Load steps as fine as 100 W / 100 VAR (or higher granularity options), allowing precise load modulation.

  • Accuracy: ±3% (customizable to tighter tolerances on request).

  • Display & monitoring: shows voltage, current, real and reactive power, frequency, power factor, etc.

  • Control options: Local manual (breakers, buttons, touch panel) or remote interface (RS232 / RS485 / USB / RJ45 / CAN / GPIB) — enabling integration into test rigs or SCADA systems.

3. Safety, Protection & Reliability

  • Emergency-stop (E-stop) protection to instantly remove load under critical conditions.

  • Over-temperature, fan failure, over-current, short circuit, and insufficient air flow protection.

  • Grounding protection and isolation to ensure safe operation.

  • IP rating (e.g. IP20 standard) (optional upgrades for harsher environments).

  • Thermal management: side air intake / top exhaust, modular airflow design to reduce hotspots.

  • Designed to operate over –10 °C to +55 °C ambient, up to ~2,500 m altitude.

4. Mechanical & Modular Design

  • Enclosure constructed from heavy-gauge steel, powder-coated for corrosion resistance.

  • Modular sections for resistive and inductive elements; scalable and maintainable.

  • Forklift channels or lifting eyes provided for ease of installation.

  • Compact footprint given the power class, enabling rooftop, pad, or indoor installation.

  • Customization: different frame sizes, color (RAL family), door arrangements, cooling layouts.


Applications & Use Cases

  • Generator Commissioning & Load Acceptance Tests
    Validate that your generator set can sustain rated kVA, voltage regulation, transient response, and reactive load behavior before it enters service.

  • UPS / Power System Integration Testing
    Emulate real-world loads (including reactive loads such as motors and inductive circuits) to ensure the UPS and switchgear respond correctly under full stress.

  • Parallel Generator Synchronization & Load Sharing
    Use the RL load bank to balance and test load sharing across multiple gensets, ensuring stability during parallel operations.

  • Routine Preventive Maintenance / Health Checks
    Regular load banking helps avoid “wet stacking” (in diesel gensets running light) and can burn off carbon buildup, improving fuel efficiency and engine life.

    Many industry guidelines recommend at least annual full-load testing under rated power factor.

  • Design Validation & R&D in Power Systems
    For OEMs, labs, or integrators, the RL load bank is essential when developing alternators, power converters, controllers, or new power architectures (e.g. microgrids).

  • Data Centers, Telecom, Critical Infrastructure
    In critical facilities where downtime is not tolerated, you must ensure every component performs under combined resistive and reactive stress.


Why Choose GROADA’s RL Solution?

Credibility & Trust (E & E & A & T)

  • Expertise & Authority: GROADA has decades of experience in power testing equipment, certified by relevant quality and safety standards.

  • Certifications & Quality Control: Each RL unit undergoes factory calibration, burn-in, and full functional testing before delivery.

  • Transparent Specifications: All electrical, thermal, mechanical parameters are documented and open to customer review or 3rd-party validation.

  • Post-Sales Support & Warranty: GROADA offers technical support, spare parts, and extended warranties — helping clients confidently deploy and maintain systems.

Market Differentiators

  • Integrated dual-mode design eliminates the need to buy separate resistive and inductive banks — saving cost, footprint, and complexity.

  • Fine load step resolution and remote control capability give customers flexibility for nuanced stress tests.

  • Strong reliability and proven design reduce lifetime maintenance and downtime risk.

  • Customs and configurations possible: if your project needs a custom voltage, power factor, enclosure, or interface, GROADA can accommodate.