GROADA-AC380V-150KW-RL Resistieve laadbank
The GROADA-AC380V-150KW-RL resistive load bank is a high-performance testing device designed to simu...
| Model | AC220V-10KVA-RL | het AC380De V-30KVA-RL | het AC380De V-60KVA-RL | het AC380De V-100KVA-RL | het AC380De V-300KVA-RL | het AC380De V-500KVA-RL | het AC380De V-1000KVA-RL |
| Nominale vermogen | RL = 10KVA | RL = 30KVA | RL = 60KVA | RL = 100KVA | RL = 300KVA | RL = 500KVA | RL = 1000KVA |
| R = 10KW; L = 6KVA | R = 30KW; L = 18KVA | R = 60KW; L = 36KVA | R = 100KW; L = 60KVA | R = 300KW; L = 180KVA | R = 500KW; L = 300KVA | R = 1000KW; L = 600KVA | |
| Input stroom | 0-45A | 0-45A | 0-90A | 0-150A | 0-450A | 0-750A | 0-1500A |
| Grootte (breedte * diepte * hoogte mm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| gewicht | 25 kg | 40 kg | 80 kg | 130 kg | 250 kg | 550 kg | 750 kg |
| Minimale lading | 100W | 100W | 100W | 500W | 1kw | 5 kw | 10 kw |
| Andere minimale laadmacht kan volgens vereisten worden aangepast | |||||||
| Ingangsspanning | AC220 / 230V | AC380 / 400V | |||||
| Andere ingangsspanning kan volgens vereisten worden aangepast | |||||||
| vermogensfactor | PF = 0,8/1,0 (andere vermogensfactor kan volgens vereisten worden aangepast) | ||||||
| Algemene nauwkeurigheid | 3% (andere nauwkeurigheidsvereisten kunnen volgens vereisten worden aangepast) | ||||||
| Controle modus | Lokale handmatige/externe gastcomputer (lokale handmatige besturingsmodus: schakelaar/knop/aanraakscherm drieweg optioneel, andere methoden kunnen worden aangepast zoals vereist) | ||||||
| Interface op afstand | RS232/RS485/USB/RJ45/CAN/GPIB (andere interfacemodies kunnen volgens vereisten worden aangepast) | ||||||
| Beschermingsfunctie | Bescherming tegen noodstop, bescherming tegen overtemperatuur, bescherming tegen ventilatorbelasting, bescherming tegen aarding (selecteer bescherming tegen overspanning, bescherming tegen overstroom, bescherming tegen kortsluiting, overbelasting van de ventilator, onvoldoende luchtvolume) | ||||||
| Werkende voeding | AC220V | AC220V / 380V | AC380V | ||||
| Vertoningsnauwkeurigheid | 0,5 niveau (andere expliciete precisie kan volgens vereisten worden aangepast) | ||||||
| Weergave parameters | Spanning, stroom, vermogen, frequentie, vermogensfactor, enz. (andere expliciete methoden kunnen volgens vereisten worden aangepast) | ||||||
| Koude zekere manier | Zijluchtingang en bovenluchtuitlaat (andere luchtuitlaatmethoden kunnen volgens vereisten worden aangepast) | ||||||
| Beschermingsniveau | IP20 (andere beschermingsniveau kan volgens vereisten worden aangepast) | ||||||
| Kleur van uiterlijk | RAL7035 (andere kleuren kunnen volgens vereisten worden aangepast) | ||||||
| Werktemperatuur | -10 ℃ ~ 55 ℃ | ||||||
| Relatieve vochtigheid | ≤95%RH | ||||||
| Hoogte | ≤ 2500 m | ||||||
DeGROADA AC 346V 50 kVA RL Laadbankis een hoogprecisie testsysteem ontworpen om beide te simulerenresistieve en inductieve belastingenvoor generatoren, UPS-systemen, turbines en elektriciteitsnetwerken.
Met een power factor van0,8 achterstandDeze eenheid reproduceert nauwkeurig echte belastingsomstandigheden, waardoor ingenieurs de prestaties kunnen verifiëren, zwakheden kunnen detecteren en storingen kunnen voorkomen voordat ze optreden.
Gebouwd voorindustriële, maritieme, datacenter- en energietoepassingenDe GROADA RL Load Bank combineert geavanceerde besturingstechnologie, modulaire constructie en robuuste veiligheidssystemen om consistente, herhaalbare en veilige belastingstestresultaten te leveren in elke omgeving.
Simuleertzowel resistieve als inductieve componententegelijkertijd een realistische weergave bieden van motoraangedreven en transformatorgebaseerde systemen.
Aanbiedingenalleen resistief, alleen inductiefofgecombineerde RL-werkingvoor flexibele testmodi.
Ideaal voor de inbedrijfstelling van generatoren, fabrieksacceptatietesten (FAT), UPS-onderhoud en systeemvalidatie onderlagging power factor conditions.
Helps ensure that your equipment performs efficiently under real operational demands—not just laboratory conditions.
Fine-tuned load step increments (e.g., 1 kW / 1 kVAR) for accurate load adjustment and gradual system ramp-up.
Modular resistive and inductive sections allow independent operation, easy calibration, and simplified servicing.
Parallel connection capability enables capacity expansion beyond 50 kVA for large-scale test systems.
Ensures smooth, stable transitions during load switching—reducing stress on test subjects and extending lifespan.
Geïntegreerddigital PLC control system with high-precision data acquisition.
Real-time display and recording of voltage, current, power, power factor, frequency, and temperature.
Optional remote control and data logging via Ethernet / RS485 / wireless interfaces.
Automated test sequences with programmable ramp rates, dwell times, and step loads—ideal for repetitive testing and certification workflows.
Safety interlocks prevent unintended operation during testing or maintenance.
Heavy-duty, powder-coated steel enclosure ensures durability and corrosion resistance in harsh environments.
Ontworpen voorindoor or outdoor operation, with high-efficiency forced-air cooling and thermostatically controlled fans.
All circuits are fully protected by overload breakers, fuses, and fault-detection systems.
Uitgerust metover-temperature, airflow failure, overload, emergency-stop, and load-dump protection mechanisms.
Engineered to operate continuously at full load without performance degradation, ensuring long service life and stable accuracy.
Regular load bank testing prevents wet stacking—the accumulation of unburned fuel and carbon deposits in diesel engines.
By simulating realistic load conditions, it ensures complete combustion and optimal generator efficiency.
Detects voltage drops, connection issues, insulation degradation, and cooling inefficiencies before they cause failures.
Essential for routine preventive maintenance in telecom, healthcare, data centers, and utility power plants.
Built to meet or exceed international electrical and safety standards.
Each GROADA load bank undergoes full functional testing, calibration, and quality assurance before shipment.
Optional CE / ISO / UL-ready configurations available for compliance with global certification requirements.
Backed by GROADA’s comprehensive after-sales support, including commissioning assistance, spare parts supply, training, and remote diagnostics.
| Parameter | Specificatie |
|---|---|
| Model | AC 346V 50 kVA RL Load Bank |
| Rated Capacity | 50 kVA (resistive + inductive) |
| Spanning | AC 346 V (3-phase, 50/60 Hz) |
| Machtsfactor | 0.8 (lagging) |
| Laadstappen | 1 kW / 1 kVAR increments (customizable) |
| Koelmethode | Forced air cooling with automatic fan control |
| Protection | Over-temperature, airflow fault, overcurrent, emergency stop, short-circuit, load-dump |
| Controleopties | Local control panel / Remote PLC / Network control |
| Enclosure Rating | Weatherproof (IP54 / NEMA 3R optional) |
| Bedrijfsomgeving | Indoor / Outdoor – -10 °C to +50 °C |
| Bouw | Galvanized steel with powder coating |
| Modularity | Expandable capacity with parallel units |
The GROADA AC 346V 50 kVA RL Load Bank is engineered for a broad range of industrial and mission-critical applications, including:
Generator commissioning and maintenance
Validate generator output, voltage regulation, and governor response under full load.
UPS and inverter testing
Simulate both linear and reactive loads to confirm backup system reliability.
Transformer and switchgear evaluation
Test equipment under realistic load and power factor conditions.
Data center and telecom infrastructure
Conduct performance and redundancy tests for critical power systems.
Marine and offshore platforms
Verify generator performance in remote or sea-borne installations.
Industrial process power systems
Assess electrical infrastructure before live production.
Experience: Years of specialized manufacturing in resistive and reactive load banks for international markets.
Expertise: Engineering team experienced in generator testing, industrial automation, and electrical system design.
Authority: Products conform to global standards and are deployed across power generation, defense, oil & gas, and data center sectors.
Trustworthiness: Proven field performance, factory quality control, and strong after-sales technical support.
Every GROADA load bank is a reflection of our commitment to innovation, precision, and reliability. We work closely with OEMs, service contractors, and system integrators to deliver tailored power-testing solutions worldwide.
Electrical testing involves high energy levels and potential hazards. GROADA ensures every RL Load Bank is designed with multi-layer protection, adhering to the latest international safety directives.
All units are subjected to full-load endurance tests, insulation verification, and thermal stability trials prior to delivery—ensuring your system operates safely, efficiently, and within specification throughout its life cycle.
GROADA offers complete post-delivery services, including:
On-site installation and commissioning support
Operator training and technical documentation
Calibration and periodic inspection programs
Spare parts availability and rapid global logistics
Remote technical assistance and diagnostics
We ensure long-term operational stability and minimum downtime, protecting your investment and productivity.
Ensure your power systems are always ready for real-world performance.
Contact GROADA today to discuss your AC 346V 50 kVA RL Load Bank requirements, request a quotation, or schedule an engineering consultation.
Trust GROADA—your global partner in professional load testing and power reliability.