Banco de carga AC

Banco de carga inductiva resistiva GROADA-AC346V-50KVA-RL

★★★★★
Productos principales:
  • Banco de carga de CA: R / RL / RLC / RCD
  • Banco de carga de corriente continua: DC5V - 2000V, 0A - 5000A

modeloAC220V-10KVA-RLAC380V-30KVA-RLAC380V-60KVA-RLAC380V-100KVA-RLAC380V-300KVA-RLAC380V-500KVA-RLAC380V-1000KVA-RL
Potencia nominalRL = 10KVARL = 30KVARL = 60KVARL = 100KVARL = 300KVARL = 500KVARL = 1000KVA
R = 10KW; L = 6KVAR = 30KW; L = 18KVAR = 60KW; L = 36KVAR = 100KW; L = 60KVAR = 300KW; L = 180KVAR = 500KW; L = 300KVAR = 1000KW; L = 600KVA
Corriente de entrada0-45A0-45A0-90A0-150A0-450A0-750A0-1500A
Tamaño (ancho * profundidad * altura mm)480*600*277480*600*360500*750*1000600*850*1000700*1000*16501100*1400*17001100*1500*1900
Peso25 kg40 kg80 kg130 kg250 kg550kg750 kg
Carga mínima100W100W100W500W1 KW5KW10KW
Otra potencia mínima de carga se puede personalizar según los requisitos
Voltaje de entradaAC220 / 230VAC380 / 400V
Otro voltaje de entrada se puede personalizar según los requisitos
factor de potenciaPF = 0,8/1,0 (otro factor de potencia se puede personalizar según los requisitos)
Precisión general3% (otros requisitos de precisión se pueden personalizar según los requisitos)
Modo de controlManual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera)
Interfaz remotaRS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos)
Función de protecciónProtección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente)
Fuente de alimentación de trabajoAC220VAC220V / 380VAC380V
Precisión de la pantallaNivel 0,5 (otra precisión explícita se puede personalizar según los requisitos)
Parámetros de visualizaciónVoltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos)
De manera segura fríaEntrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos)
Nivel de protecciónIP20 (otro nivel de protección se puede personalizar según los requisitos)
Color de aparienciaRAL7035 (otros colores se pueden personalizar según los requisitos)
Temperatura de trabajo-10 ℃ ~ 55 ℃
Humedad relativa ≤95% RH
Altitud ≤ 2500 m


GROADA AC346V-50KVA RL AC Load Bank

GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet designed for testing and verification of power equipment such as generators, UPS systems, inverters, data centers, and industrial power supplies.
This model supports accurate power factor adjustment (0.8 lagging to 0.8 leading), modular expansion, advanced cooling design, and intelligent protection mechanisms, ensuring stable and reliable performance in demanding applications.


Características clave

  • Potencia nominal:50 kVA

  • Voltaje nominal:346 V AC (customizable for 380 V / 400 V / 415 V)

  • Tipo de carga:Resistive + Inductive

  • Adjustable Power Factor: 0.8 lagging ~ 1.0 ~ 0.8 leading

  • Modular Design: expandable by parallel connection

  • Refrigeración:high-efficiency forced air cooling

  • Protection: overload, overheat, short-circuit, fan failure alarm

  • Control & Communication: manual panel + RS-485/Modbus/Ethernet remote monitoring

  • Applications: power plants, generator testing, UPS aging test, renewable energy systems, EV charging stations


Especificaciones técnicas

ParámetroValue
Potencia nominal50 kVA
Voltage Range300 – 380 V AC (custom options)
Tipo de cargaResistive + Inductive (RL)
Power Factor Adjustment0.8 lagging ~ 1.0 ~ 0.8 leading
Sistema de refrigeraciónForced air cooling, top exhaust
Protection FunctionsOverload / Overheat / Short circuit / Fan failure
Modo de controlManual local control + Remote monitoring
Communication ProtocolsRS-485 / Modbus / Ethernet
Cabinet DesignRugged enclosure, IP protection customizable
Working Temperature–10℃ ~ +45℃

Working Principle

The load bank integrates resistive elementsyinductive coils in modular sections.

  • Load Control: PWM control enables precise step adjustment of load capacity.

  • Power Factor Simulation: Supports real-time adjustment to simulate inductive and capacitive conditions.

  • Protection Mechanism: Temperature sensors, fan monitoring, automatic unloading in case of fault.

  • Sistema de refrigeración: High-volume fans ensure fast heat dissipation and safe operation under full load.

  • Smart Monitoring: Remote control and data logging via Modbus or Ethernet.


Application Scenarios

  • Power Generation: Testing diesel / gas generators under full load and transient conditions.

  • Sistemas UPS: Long-time aging tests and reliability verification.

  • Energía Renovable: Grid-tie inverter and photovoltaic system validation.

  • Centros de datos: Simulating real IT load for facility acceptance.

  • EV Charging Stations: Power electronics and charging infrastructure testing.


Why Choose GROADA?

Compared with traditional load banks, GROADA AC load banks deliver:

  1. Higher accuracy in power factor adjustment.

  2. Better thermal management with forced air cooling.

  3. Modular and expandable architecture for flexible capacity.

  4. Advanced safety protections ensuring long service life.

  5. Remote monitoring & control for modern test environments.


Selection Guide

When choosing a load bank:

  • Potencia nominal ≥ 1.2 × tested equipment rated power.

  • Voltage Level must match system (300–380V standard, custom for 400/415/480V).

  • Factor de potencia: choose RL load bank if your DUT (device under test) involves inductive / capacitive behaviors.

  • Environment: outdoor use requires higher IP protection and enhanced cooling.


FAQ

Q1: Can the load bank run continuously at full power?
Yes, with proper ventilation, it can sustain continuous full-load operation.

Q2: How often should maintenance be performed?
Every 6–12 months: check fans, wiring terminals, resistance modules, and clean dust.

Q3: Does it support remote monitoring?
Yes, via RS-485 / Modbus / Ethernet for data logging, alarm, and control.

Q4: What protection functions are included?
Overload, overheat, short-circuit, and fan failure detection with automatic load disconnection.


Certifications & Quality Assurance

  • ISO 9001 / ISO 14001 certified manufacturer

  • CE / UL compliance (upon request)

  • Factory type test reports available (temperature rise, EMC, insulation, durability)

  • Warranty: 12 months, with global technical support


Customer Feedback

“We deployed GROADA RL load banks for generator testing in our European facility. The precision and stability exceeded expectations.”John M., Germany
“Reliable partner for UPS verification projects. Remote monitoring makes operation much easier.”David P., UK


Contact & Resources

  • 📩 Email: groada@163.com

  • ☎ Phone: +86 13342997981

  • 📍 Address: Shenzhen, China

👉 Request a Quote or Free Consultation today!

Nuestro producto