Banco de carga inductiva resistiva GROADA-AC346V-50KVA-RL
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet design...
| modelo | AC220V-10KVA-RL | AC380V-30KVA-RL | AC380V-60KVA-RL | AC380V-100KVA-RL | AC380V-300KVA-RL | AC380V-500KVA-RL | AC380V-1000KVA-RL |
| Potencia nominal | RL = 10KVA | RL = 30KVA | RL = 60KVA | RL = 100KVA | RL = 300KVA | RL = 500KVA | RL = 1000KVA |
| R = 10KW; L = 6KVA | R = 30KW; L = 18KVA | R = 60KW; L = 36KVA | R = 100KW; L = 60KVA | R = 300KW; L = 180KVA | R = 500KW; L = 300KVA | R = 1000KW; L = 600KVA | |
| Corriente de entrada | 0-45A | 0-45A | 0-90A | 0-150A | 0-450A | 0-750A | 0-1500A |
| Tamaño (ancho * profundidad * altura mm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| Peso | 25 kg | 40 kg | 80 kg | 130 kg | 250 kg | 550kg | 750 kg |
| Carga mínima | 100W | 100W | 100W | 500W | 1 KW | 5KW | 10KW |
| Otra potencia mínima de carga se puede personalizar según los requisitos | |||||||
| Voltaje de entrada | AC220 / 230V | AC380 / 400V | |||||
| Otro voltaje de entrada se puede personalizar según los requisitos | |||||||
| factor de potencia | PF = 0,8/1,0 (otro factor de potencia se puede personalizar según los requisitos) | ||||||
| Precisión general | 3% (otros requisitos de precisión se pueden personalizar según los requisitos) | ||||||
| Modo de control | Manual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera) | ||||||
| Interfaz remota | RS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos) | ||||||
| Función de protección | Protección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente) | ||||||
| Fuente de alimentación de trabajo | AC220V | AC220V / 380V | AC380V | ||||
| Precisión de la pantalla | Nivel 0,5 (otra precisión explícita se puede personalizar según los requisitos) | ||||||
| Parámetros de visualización | Voltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos) | ||||||
| De manera segura fría | Entrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos) | ||||||
| Nivel de protección | IP20 (otro nivel de protección se puede personalizar según los requisitos) | ||||||
| Color de apariencia | RAL7035 (otros colores se pueden personalizar según los requisitos) | ||||||
| Temperatura de trabajo | -10 ℃ ~ 55 ℃ | ||||||
| Humedad relativa | ≤95% RH | ||||||
| Altitud | ≤ 2500 m | ||||||
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet designed for testing and verification of power equipment such as generators, UPS systems, inverters, data centers, and industrial power supplies.
This model supports accurate power factor adjustment (0.8 lagging to 0.8 leading), modular expansion, advanced cooling design, and intelligent protection mechanisms, ensuring stable and reliable performance in demanding applications.
Potencia nominal:50 kVA
Voltaje nominal:346 V AC (customizable for 380 V / 400 V / 415 V)
Tipo de carga:Resistive + Inductive
Adjustable Power Factor: 0.8 lagging ~ 1.0 ~ 0.8 leading
Modular Design: expandable by parallel connection
Refrigeración:high-efficiency forced air cooling
Protection: overload, overheat, short-circuit, fan failure alarm
Control & Communication: manual panel + RS-485/Modbus/Ethernet remote monitoring
Applications: power plants, generator testing, UPS aging test, renewable energy systems, EV charging stations
| Parámetro | Value |
|---|---|
| Potencia nominal | 50 kVA |
| Voltage Range | 300 – 380 V AC (custom options) |
| Tipo de carga | Resistive + Inductive (RL) |
| Power Factor Adjustment | 0.8 lagging ~ 1.0 ~ 0.8 leading |
| Sistema de refrigeración | Forced air cooling, top exhaust |
| Protection Functions | Overload / Overheat / Short circuit / Fan failure |
| Modo de control | Manual local control + Remote monitoring |
| Communication Protocols | RS-485 / Modbus / Ethernet |
| Cabinet Design | Rugged enclosure, IP protection customizable |
| Working Temperature | –10℃ ~ +45℃ |
The load bank integrates resistive elementsyinductive coils in modular sections.
Load Control: PWM control enables precise step adjustment of load capacity.
Power Factor Simulation: Supports real-time adjustment to simulate inductive and capacitive conditions.
Protection Mechanism: Temperature sensors, fan monitoring, automatic unloading in case of fault.
Sistema de refrigeración: High-volume fans ensure fast heat dissipation and safe operation under full load.
Smart Monitoring: Remote control and data logging via Modbus or Ethernet.
Power Generation: Testing diesel / gas generators under full load and transient conditions.
Sistemas UPS: Long-time aging tests and reliability verification.
Energía Renovable: Grid-tie inverter and photovoltaic system validation.
Centros de datos: Simulating real IT load for facility acceptance.
EV Charging Stations: Power electronics and charging infrastructure testing.
Compared with traditional load banks, GROADA AC load banks deliver:
Higher accuracy in power factor adjustment.
Better thermal management with forced air cooling.
Modular and expandable architecture for flexible capacity.
Advanced safety protections ensuring long service life.
Remote monitoring & control for modern test environments.
When choosing a load bank:
Potencia nominal ≥ 1.2 × tested equipment rated power.
Voltage Level must match system (300–380V standard, custom for 400/415/480V).
Factor de potencia: choose RL load bank if your DUT (device under test) involves inductive / capacitive behaviors.
Environment: outdoor use requires higher IP protection and enhanced cooling.
Q1: Can the load bank run continuously at full power?
Yes, with proper ventilation, it can sustain continuous full-load operation.
Q2: How often should maintenance be performed?
Every 6–12 months: check fans, wiring terminals, resistance modules, and clean dust.
Q3: Does it support remote monitoring?
Yes, via RS-485 / Modbus / Ethernet for data logging, alarm, and control.
Q4: What protection functions are included?
Overload, overheat, short-circuit, and fan failure detection with automatic load disconnection.
ISO 9001 / ISO 14001 certified manufacturer
CE / UL compliance (upon request)
Factory type test reports available (temperature rise, EMC, insulation, durability)
Warranty: 12 months, with global technical support
“We deployed GROADA RL load banks for generator testing in our European facility. The precision and stability exceeded expectations.” — John M., Germany
“Reliable partner for UPS verification projects. Remote monitoring makes operation much easier.” — David P., UK
📩 Email: groada@163.com
☎ Phone: +86 13342997981
📍 Address: Shenzhen, China
👉 Request a Quote or Free Consultation today!