GROADA-AC220V-15KW-RLC Banco de carga fabricante
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| modelo | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Potencia nominal | RLC = 10KVA | RLC = 30KVA | RLC = 60KVA | RLC = 100KVA | RLC = 200KVA | RLC = 300KVA |
| R = 10KW; L = 10KVA C = 10KVA | R = 30KW; L = 30KVA; C = 30KVA | R = 60KW; L = 60KVA; C = 60KVA | R = 100KW; L = 100KVA; C = 100KVA | R = 200KW; L = 200KVA; C = 200KVA | R = 300KW; L = 300KVA; C = 300KVA | |
| Otro poder se puede personalizar según los requisitos | ||||||
| Tamaño (ancho * profundidad * altura mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Peso | 120 kg | 380kg | 580 kg | 880 kg | 1500 kg | 2500kg |
| Voltaje de entrada | AC220 / 230V | AC380 / 400V | ||||
| Otro voltaje de entrada se puede personalizar según los requisitos | ||||||
| Corriente de entrada | 0-45A | 0-45A | 0-90A | 0-150A | 0-300A | 0-450A |
| Carga mínima | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 1KW; L = 1KVA; C = 1KVA | R = 1KW; L = 1KVA; C = 1KVA |
| Otra potencia mínima de carga se puede personalizar según los requisitos | ||||||
| factor de potencia | PF = 0.1 ~ 1.0 (otro factor de potencia se puede personalizar según los requisitos) | |||||
| Precisión general | 3% (otros requisitos de precisión se pueden personalizar según los requisitos) | |||||
| Modo de control | Manual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera) | |||||
| Interfaz remota | RS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos) | |||||
| Función de protección | Protección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente) | |||||
| Fuente de alimentación de trabajo | AC220V | AC220V / 380V | AC380V | |||
| Precisión de la pantalla | Nivel 0,5 (otra precisión explícita se puede personalizar según los requisitos) | |||||
| Parámetros de visualización | Voltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos) | |||||
| De manera segura fría | Entrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos) | |||||
| Nivel de protección | IP20 (otro nivel de protección se puede personalizar según los requisitos) | |||||
| Color de apariencia | RAL7035 (otros colores se pueden personalizar según los requisitos) | |||||
| Temperatura de trabajo | -10 ℃ ~ 55 ℃ | |||||
| Humedad relativa | ≤95% RH | |||||
| Altitud | ≤ 2500 m | |||||
Ensure Optimal Performance, Reliability, and Safety Across Your Power Infrastructure
ElGROADA AC380V 20KW RLC Load Bank is a high-performance testing solution designed for validating the reliability and efficiency of power generation and distribution systems. Combining resistive, inductive, and capacitive loads, it simulates real-world electrical conditions, enabling engineers and technicians to identify potential issues before they become critical failures.
Whether for generators, UPS systems, data centers, or renewable energy integration, this load bank delivers precise, repeatable, and safe testing results, ensuring your critical power systems operate at peak efficiency under any scenario.
Incorporates Cargas resistivas (R), inductivas (L) y capacitivas (C) to accurately replicate the behavior of real electrical systems.
Allows precise simulation of different load types, including reactive and non-linear loads.
Supports a wide power factor range from 0.1 to 1.0, enabling testing under various operating conditions.
Critical for validating system performance in applications where reactive loads are present.
Modular architecture ensures easy scalability and allows customization based on specific testing needs.
Compact, robust, and transportable design ensures versatility in both field and laboratory environments.
Intuitive control panel provides real-time monitoring of voltage, current, power, and power factor.
Optional remote control functionality allows for safe operation from a distance.
Equipped with overload protection, short-circuit protection, and over-temperature alarms.
Ensures operator safety and prevents damage to both the load bank and tested equipment.
Simulates realistic load conditions to verify generator performance, efficiency, and reliability.
Ensures compliance with operational standards and minimizes the risk of failure during peak demand.
Tests UPS functionality under varied resistive, inductive, and capacitive loads.
Ensures backup power systems maintain reliability during outages.
Evaluates solar, wind, or hybrid power systems under dynamic load conditions.
Helps optimize inverter and storage system performance for consistent energy delivery.
Confirms that backup power systems and generators can handle high-demand, critical loads.
Prevents downtime and ensures business continuity.
The GROADA AC380V 20KW RLC Load Bank is designed to meet international safety and performance standards, ensuring both reliability and operational compliance:
IEEE 1547 – Standard for testing distributed energy resources.
NFPA 110 – Requirements for emergency and standby power systems.
ISO 8528-10 – Load acceptance testing standards for generating sets.
Compliance with these standards guarantees that the load bank can be safely and effectively integrated into professional power testing environments worldwide.
Reliability Assurance – Early detection of system weaknesses prevents critical failures.
Performance Optimization – Testing under real-world load conditions ensures generators, UPS units, and other systems perform efficiently.
Cost Efficiency – Proactive testing reduces costly emergency repairs and downtime.
Operational Confidence – Verifies that backup power systems are ready for emergency operation.
| Especificación | Detalles |
|---|---|
| Potencia nominal | 20KW |
| Voltaje | AC380V |
| Frecuencia | 50/60Hz |
| Factor de potencia | 0.1 – 1.0 |
| Modo de control | Local panel and optional remote |
| Características de seguridad | Overload, short circuit, over-temp alarms |
GROADA RLC Load Banks are trusted globally by power generation companies, data centers, and critical infrastructure operators. Our solutions are engineered for accuracy, durability, and ease of use, providing peace of mind for engineers and facility managers alike.
Email: groadacn@163.com
Phone: +86-755-23339096
Address:Shenzhen, Guangdong, China