Banco de carga de prueba del inversor

Banco de carga del inversor GROADA-AC120V-50KVA-RCD

★★★★★
Productos principales:
  • Banco de carga de CA: R / RL / RLC / RCD
  • Banco de carga de corriente continua: DC5V - 2000V, 0A - 5000A


modeloAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V -30KW-RCDAC380V -50KW-RCDAC380V -60KW-RCDAC380V -100KW-RCDAC380V -200KW-RCD
Potencia nominalR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Corriente de entrada0-22A0-45A0-45A0-90A0-45A0-300A0-450A0-600A0-750A
Tamaño (ancho * profundidad * altura mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Peso50 kg80 kg100 kg130 kg200 kg300 kg350kg450 kg550kg
Voltaje de entradaAC220 / 230VAC380 / 400V
Otro voltaje de entrada se puede personalizar según los requisitos
Carga mínima100W100W100W100W100W1 KW1 KW1 KW1 KW
Otra potencia mínima de carga se puede personalizar según los requisitos
Precisión general3% (otros requisitos de precisión se pueden personalizar según los requisitos)
factor de potenciaPF = 0,6 ~ 1,0
coeficiente de pico2 a 3
Modo de controlManual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera)
Interfaz remotaRS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos)
Función de protecciónProtección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente)
Fuente de alimentación de trabajoAC220VAC220V / AC380V
Precisión de la pantallaNivel 0,5 (otra precisión explícita se puede personalizar según los requisitos)
Parámetros de visualizaciónVoltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos)
De manera segura fríaEntrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos)
Nivel de protecciónIP20 (otro nivel de protección se puede personalizar según los requisitos)
Color de aparienciaRAL7035 (otros colores se pueden personalizar según los requisitos)
Temperatura de trabajo-10 ℃ ~ 55 ℃
Humedad relativa ≤95% RH
Altitud ≤ 2500 m


Banco de carga del inversor RCD GROADA AC120V 50 kVA — Pruebas de carga fiables para inversores grandes


Introducción / Breve resumen (segundo párrafo)

El banco de carga del inversor RCD AC120V 50 kVA de GROADA está diseñado específicamente para la prueba y verificación de carga del inversor de alta potencia. Permite a los fabricantes, integradores de sistemas y laboratorios de pruebas ejecutar pruebas de carga completa, carga parcial, transitorias y de conducción de forma fiable y segura. Este banco de carga ayuda a validar el rendimiento del inversor en condiciones reales, garantizando una salida estable, el cumplimiento y la fiabilidad a largo plazo.


Características clave & Capacidades

  • Manejo de alta potencia
    Este banco de carga soporta cargas continuas y dinámicas de hasta 50 kVA a AC120V, lo que lo hace adecuado para inversores medianos a grandes o conjuntos de inversores.

  • Integración de protección RCD
    Incluye características de seguridad RCD (Dispositivo de Corriente Residual) para proteger contra fugas o fallas de tierra durante las pruebas.

  • Niveles de carga ajustables
    Los usuarios pueden definir cargas incrementales escalonadas o continuamente variables, lo que permite la simulación de condiciones de funcionamiento ligeras, medianas y completas.

  • Respuesta rápida & Transiciones de carga
    Puede simular cambios rápidos de carga o cargas por pasos, lo que es esencial para validar la respuesta transitoria del inversor, la recuperación y el rendimiento de recorrido.

  • Monitoreo de precisión y Medidas
    Los módulos de medición integrados capturan la tensión, la corriente, el factor de potencia, la eficiencia, el THD, el parpadeo y la distorsión de la forma de onda en tiempo real.

  • Gestión térmica y Protección
    Equipado con sensores de temperatura, protección contra sobretemperaturas e infraestructura de enfriamiento para garantizar un funcionamiento estable durante pruebas de larga duración.

  • Modular & Diseño expandible
    La unidad puede extenderse o modularizarse para una potencia nominal más alta o un funcionamiento paralelo, lo que permite una escalabilidad flexible.

  • Cumplimiento de normas
    Diseñado para cumplir con las normas de seguridad y medición (por ejemplo, IEC, UL, etc.), asegurando que el entorno de prueba sea creíble y confiable.


Why Use an Inverter Load Bank?

Ensuring Performance & Reliability

Even certified inverters may fail under real or stress conditions: in one industry test program, one-third of PV inverters failed key performance or safety tests despite having IEC/UL certification.
Using a load bank helps you uncover issues—such as thermal instability, waveform distortion, overcurrent trips, or inability to ride through transients—before field deployment.

Compliance & Certification Support

To meet grid-codes or certification requirements (e.g. IEEE 1547.1 for distributed energy resources), inverter systems must pass a variety of stress and dynamic tests. 
A robust load bank is essential to simulate worst-case grid or load conditions.

Accelerated Validation & QA

In production or R&D, load banks facilitate fast, repeatable testing cycles. This is especially valuable in automotive, PV, ESS (energy storage systems), or industrial applications where inverter reliability is critical.

Market Growth & Demand

  • The global end-of-line inverter testing market was valued at about USD 1.27 billion in 2024 and is expected to reach USD 2.85 billion by 2033, a strong CAGR of ≈ 9.4 %. 

  • ElPV inverter testing system market alone was valued at around USD 220 million in 2024 and is projected to grow to ~USD 450 million by 2033.

  • The overall inverter market (across sectors) is huge — valued at over USD 22 billion in 2024 and forecast to exceed USD 70+ billion by 2032, driven by renewables, electrification, and energy storage expansion. 

These trends underscore that high-quality test infrastructure (like load banks) is increasingly indispensable.


Typical Test Applications & Use Cases

  1. Full-Load Endurance Tests
    Run the inverter at rated output for prolonged periods to verify thermal stability, component degradation, and long-term reliability.

  2. Partial-Load & Efficiency Mapping
    Apply loads at, say, 25%, 50%, 75%, and 100% to map efficiency curves, power factor, and losses across operating range.

  3. Transient & Step-Load Tests
    Introduce sudden load changes (e.g. 10% → 80% → 30%) and monitor how the inverter handles transient events, recovery time, and waveform stability.

  4. Ride-Through / Fault Simulation
    Simulate grid disturbances, faults, or momentary interruptions and evaluate how the inverter maintains output or recovers — critical for compliance and stability.

  5. Harmonic / Distortion Testing
    Introduce non-pure loads or harmonic injection and assess how the inverter performs under nonlinear or distorted loads.

  6. Multi-Unit / Parallel System Testing
    For systems with multiple parallel inverter modules, test how they share load, respond to imbalance, or handle switching dynamics.


Technical Considerations & Best Practices

  • Load Type & Modeling
    Use a mix of resistive, inductive, and capacitive loads to emulate real-world conditions. Many inverter tests require reactive power handling and realistic load emulation. 

  • Instrumentation Accuracy
    Ensure measurement modules are precise (e.g. ±0.1% class or better), especially for efficiency and power factor comparisons.

  • Thermal Derating
    At high power, ambient temperature and internal heating can reduce effective load capacity — plan for margin or active cooling.

  • Transient Speed & Control Loop Interaction
    The load bank must respond quickly and smoothly to test pulses so the inverter’s control system isn’t tricked by overly slow transitions.

  • Isolation & Safety
    Proper galvanic isolation, overcurrent protection, and residual current detection (RCD) must be in place to safeguard test hardware and personnel.

  • Data Logging & Analysis
    Capture high-resolution data (sampling ≥ 1 kHz or more) and provide software tools to analyze instability, harmonics, voltage dips, or anomalies.


Why Choose the GROADA 50 kVA RCD Load Bank?

  • Tailored for High-Power Inverters: Many load banks top out at a few tens of kW; 50 kVA at AC120V positions this unit well above standard commodity test rigs.

  • Diseño centrado en la seguridad: Built-in RCD protection helps mitigate faults and enhances confidence in testing environments.

  • Scalability & Flexibility: Its modular architecture allows future upgrades or parallel operation for larger systems.

  • Precision & Responsiveness: Designed for fast load steps and stable control, ideal for dynamic performance tests.

  • Proven Technology & Support: Backed by GROADA’s expertise and experience in power electronics testing.

Nuestro producto