Banco de carga inductiva resistiva GROADA-AC346V-50KVA-RL
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet design...
| modelo | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Potencia nominal | RLC = 10KVA | RLC = 30KVA | RLC = 60KVA | RLC = 100KVA | RLC = 200KVA | RLC = 300KVA |
| R = 10KW; L = 10KVA C = 10KVA | R = 30KW; L = 30KVA; C = 30KVA | R = 60KW; L = 60KVA; C = 60KVA | R = 100KW; L = 100KVA; C = 100KVA | R = 200KW; L = 200KVA; C = 200KVA | R = 300KW; L = 300KVA; C = 300KVA | |
| Otro poder se puede personalizar según los requisitos | ||||||
| Tamaño (ancho * profundidad * altura mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Peso | 120 kg | 380kg | 580 kg | 880 kg | 1500 kg | 2500kg |
| Voltaje de entrada | AC220 / 230V | AC380 / 400V | ||||
| Otro voltaje de entrada se puede personalizar según los requisitos | ||||||
| Corriente de entrada | 0-45A | 0-45A | 0-90A | 0-150A | 0-300A | 0-450A |
| Carga mínima | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 1KW; L = 1KVA; C = 1KVA | R = 1KW; L = 1KVA; C = 1KVA |
| Otra potencia mínima de carga se puede personalizar según los requisitos | ||||||
| factor de potencia | PF = 0.1 ~ 1.0 (otro factor de potencia se puede personalizar según los requisitos) | |||||
| Precisión general | 3% (otros requisitos de precisión se pueden personalizar según los requisitos) | |||||
| Modo de control | Manual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera) | |||||
| Interfaz remota | RS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos) | |||||
| Función de protección | Protección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente) | |||||
| Fuente de alimentación de trabajo | AC220V | AC220V / 380V | AC380V | |||
| Precisión de la pantalla | Nivel 0,5 (otra precisión explícita se puede personalizar según los requisitos) | |||||
| Parámetros de visualización | Voltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos) | |||||
| De manera segura fría | Entrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos) | |||||
| Nivel de protección | IP20 (otro nivel de protección se puede personalizar según los requisitos) | |||||
| Color de apariencia | RAL7035 (otros colores se pueden personalizar según los requisitos) | |||||
| Temperatura de trabajo | -10 ℃ ~ 55 ℃ | |||||
| Humedad relativa | ≤95% RH | |||||
| Altitud | ≤ 2500 m | |||||
Desbloquea una precisión, fiabilidad y versatilidad sin igual en las pruebas de sistemas de energía con elBanco de carga GROADA AC380V-20KW-RLCDiseñado para profesionales de los sectores energético, industrial y renovable, este banco de carga avanzado proporciona una simulación precisa de carga resistiva, inductiva y capacitiva (RLC) para generadores, sistemas UPS, inversores e infraestructuras de carga de vehículos eléctricos (EV).
Ya sea que esté poniendo en marcha nuevos equipos de energía, validando el rendimiento operativo o realizando un mantenimiento rutinario, el banco de carga AC380V-20KW-RLC ofrece resultados en los que puede confiar.
Potencia nominal20 kW a 380V AC
Tipo de cargaResistivo, Inductivo, Capacitivo (RLC)
Clasificación de voltaje : 380V CA
RefrigeraciónSistema enfriado por aire eficiente para una gestión térmica consistente
Interfaz de control: Digital panel with LED indicators displaying real-time load, voltage, current, and power factor
Mecanismos de seguridad: Over-temperature protection, branch circuit fuses, and integrated sensors to prevent overload or overheating
Design & Portability: Compact, lightweight, and durable chassis, optimized for easy transport and deployment in varied environments
The RLC configuration allows for the replication of realistic electrical loads. By simulating resistive, inductive, and capacitive components, this load bank ensures your power systems are tested under true operational conditions. This capability is critical for validating generator performance, UPS reliability, and inverter efficiency. Accurate load testing minimizes the risk of system failure and reduces downtime, ensuring operational continuity for critical infrastructure.
Equipped with a sophisticated digital control panel, the AC380V-20KW-RLC Load Bank provides real-time data on all key electrical parameters. Users can monitor voltage, current, power factor, and load trends continuously. The system supports predictive maintenance and condition-based monitoring, enabling engineers to detect potential issues before they escalate, thereby enhancing equipment lifespan and reliability.
GROADA emphasizes eco-friendly design without compromising performance. The load bank’s air-cooled system reduces energy consumption while maintaining optimal testing conditions. By integrating energy-efficient components and minimizing operational losses, this load bank aligns with global sustainability trends in industrial power management.
Safety is paramount in high-power testing environments. The AC380V-20KW-RLC Load Bank incorporates multiple layers of protection, including thermal sensors, fuses, and automated shutdown mechanisms. These features ensure secure operation, even during high-stress testing scenarios, safeguarding both operators and equipment.
The GROADA load bank serves a wide spectrum of applications:
Prueba del generador – Verify output, stability, and efficiency
UPS System Validation – Ensure backup power reliability under full load conditions
Inverter Performance Evaluation – Test renewable energy integration and grid stability
EV Charging Infrastructure Testing – Simulate load profiles for EV stations and fleet systems
Its adaptability makes it indispensable for energy providers, industrial facilities, and research laboratories seeking dependable testing solutions.
The global load bank market is expanding rapidly, fueled by increasing investments in renewable energy, power grid modernization, and industrial automation. Reliable power testing is critical for commissioning and maintaining generators, UPS systems, and renewable energy equipment.
Emerging trends shaping the market include:
Digital Monitoring and Automation – Load banks with real-time data analytics enable predictive maintenance and reduce human error
Modular and Portable Designs – Compact, transportable units allow flexible deployment across multiple sites
Energy-Efficient Systems – Reducing operational costs and supporting sustainable practices in alignment with green energy initiatives
By leveraging these advancements, the AC380V-20KW-RLC Load Bank ensures cutting-edge testing capabilities aligned with industry best practices.
Engineered for precision, reliability, and longevity, the GROADA AC380V-20KW-RLC Load Bank is trusted by engineers and energy managers worldwide. Its combination of advanced RLC simulation, real-time digital monitoring, and robust safety mechanisms makes it a top choice for anyone who requires accurate, reliable, and safe power testing solutions.
Invest in performance, dependability, and innovation—experience the GROADA difference in AC load testing.