GROADA-AC120V-5KW-RCD Banco de carga fabricante
The GROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate nonlinea...
| modelo | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V -30KW-RCD | AC380V -50KW-RCD | AC380V -60KW-RCD | AC380V -100KW-RCD | AC380V -200KW-RCD |
| Potencia nominal | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Corriente de entrada | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| Tamaño (ancho * profundidad * altura mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Peso | 50 kg | 80 kg | 100 kg | 130 kg | 200 kg | 300 kg | 350kg | 450 kg | 550kg |
| Voltaje de entrada | AC220 / 230V | AC380 / 400V | |||||||
| Otro voltaje de entrada se puede personalizar según los requisitos | |||||||||
| Carga mínima | 100W | 100W | 100W | 100W | 100W | 1 KW | 1 KW | 1 KW | 1 KW |
| Otra potencia mínima de carga se puede personalizar según los requisitos | |||||||||
| Precisión general | 3% (otros requisitos de precisión se pueden personalizar según los requisitos) | ||||||||
| factor de potencia | PF = 0,6 ~ 1,0 | ||||||||
| coeficiente de pico | 2 a 3 | ||||||||
| Modo de control | Manual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera) | ||||||||
| Interfaz remota | RS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos) | ||||||||
| Función de protección | Protección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente) | ||||||||
| Fuente de alimentación de trabajo | AC220V | AC220V / AC380V | |||||||
| Precisión de la pantalla | Nivel 0,5 (otra precisión explícita se puede personalizar según los requisitos) | ||||||||
| Parámetros de visualización | Voltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos) | ||||||||
| De manera segura fría | Entrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos) | ||||||||
| Nivel de protección | IP20 (otro nivel de protección se puede personalizar según los requisitos) | ||||||||
| Color de apariencia | RAL7035 (otros colores se pueden personalizar según los requisitos) | ||||||||
| Temperatura de trabajo | -10 ℃ ~ 55 ℃ | ||||||||
| Humedad relativa | ≤95% RH | ||||||||
| Altitud | ≤ 2500 m | ||||||||
ElGROADA AC380V 30KW RCD Load Bank is a state-of-the-art solution for testing and validating modern power systems. Designed to replicate real-world electrical conditions, it provides precise simulation of non-linear loads, enabling engineers to assess the performance, efficiency, and reliability of generators, UPS systems, inverters, and other critical power equipment.
Whether for industrial operations, data centers, or renewable energy installations, this load bank ensures your systems are robust, resilient, and ready for any electrical scenario.
| Características | Especificación |
|---|---|
| Potencia nominal | 30 kW (Resistive) / 30 kVA (Capacitive) |
| Voltaje | AC 380V, 3-phase |
| Frecuencia | 50/60 Hz |
| Rango del factor de potencia | 0.6 – 1.0 (adjustable) |
| Maximum Current | Up to 576A (3-phase) |
| Tipo de carga | Resistive-Capacitive (RCD) |
| Safety Protections | Overcurrent, overvoltage, overtemperature, emergency stop |
Key Insight: The combination of resistive and capacitive elements allows this load bank to generate non-linear load profiles that closely mimic modern electronic equipment behavior, ensuring realistic testing conditions.
Modern electrical systems often encounter non-linear loads due to electronic devices like computers, servers, and inverters. The RCD load bank replicates these conditions, allowing engineers to evaluate power system performance, including voltage stability, current harmonics, and thermal response under real operating scenarios.
Elpower factor adjustment range (0.6–1.0) ensures that your equipment can be tested under a variety of load conditions, from capacitive-heavy to predominantly resistive loads. This flexibility is critical for validating UPS, generator, and inverter performance under diverse operational scenarios.
With the ability to handle up to 576A in three-phase configurations, this load bank is suitable for medium to high-capacity power systems. It allows full-load testing without overloading the equipment under test, ensuring reliability and operational safety.
Safety is paramount in load testing. The GROADA RCD Load Bank is equipped with:
Overcurrent protection to prevent excessive load damage
Overvoltage protection to safeguard connected equipment
Overtemperature protection for internal heating control
Emergency stop for immediate shutdown during unexpected situations
The digital display provides continuous monitoring of:
Voltage and current
Real-time power consumption
Power factor and load distribution
This ensures precise, data-driven testing with minimal operator error.
The GROADA AC380V 30KW RCD Load Bank is ideal across multiple sectors:
Centros de datos: Test UPS and backup generators under realistic, fluctuating load conditions.
Telecomunicaciones: Validate the reliability of inverters and backup power for mission-critical networks.
Industrial Manufacturing: Confirm generator and electrical system resilience in factories and production facilities.
Energía Renovable: Evaluate inverters and hybrid energy systems in solar and wind installations to ensure optimal performance.
This load bank aligns with industry standards and best practices, including:
IEEE 1547 – Interconnection and performance of distributed energy resources
IEEE 112.3 – Generator testing methods
ISO 8528 – Reciprocating internal combustion engine-driven generating sets
Compliance guarantees trustworthy, repeatable testing results for both local and international projects.
Enhanced Testing Accuracy: Realistic simulation of non-linear loads ensures precise system evaluation.
Wide Application Range: Suitable for data centers, industrial sites, telecom networks, and renewable energy projects.
Long-Term Reliability: High-quality components for consistent performance over time.
Operator Safety: Built-in protections and emergency stop mechanisms safeguard users and equipment.
Investing in the GROADA AC380V 30KW RCD Load Bank means preparing your power systems for real-world demands, minimizing downtime, and optimizing operational efficiency.