GROADA-AC120V-5KW-RCD Banco de carga fabricante
The GROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate nonlinea...
| modelo | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| Potencia nominal | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Corriente de entrada | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| Tamaño (ancho * profundidad * altura mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Peso | 50 kg | 80 kg | 100 kg | 130 kg | 200 kg | 300 kg | 350kg | 450 kg | 550kg |
| Voltaje de entrada | AC220 / 230V | AC380 / 400V | |||||||
| Otro voltaje de entrada se puede personalizar según los requisitos | |||||||||
| Carga mínima | 100W | 100W | 100W | 100W | 100W | 1 KW | 1 KW | 1 KW | 1 KW |
| Otra potencia mínima de carga se puede personalizar según los requisitos | |||||||||
| Precisión general | 3% (otros requisitos de precisión se pueden personalizar según los requisitos) | ||||||||
| factor de potencia | PF = 0,6 ~ 1,0 | ||||||||
| coeficiente de pico | 2 a 3 | ||||||||
| Modo de control | Manual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera) | ||||||||
| Interfaz remota | RS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos) | ||||||||
| Función de protección | Protección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente) | ||||||||
| Fuente de alimentación de trabajo | AC220V | AC220V / AC380V | |||||||
| Precisión de la pantalla | Nivel 0,5 (otra precisión explícita se puede personalizar según los requisitos) | ||||||||
| Parámetros de visualización | Voltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos) | ||||||||
| De manera segura fría | Entrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos) | ||||||||
| Nivel de protección | IP20 (otro nivel de protección se puede personalizar según los requisitos) | ||||||||
| Color de apariencia | RAL7035 (otros colores se pueden personalizar según los requisitos) | ||||||||
| Temperatura de trabajo | -10 ℃ ~ 55 ℃ | ||||||||
| Humedad relativa | ≤95% RH | ||||||||
| Altitud | ≤ 2500 m | ||||||||
ElBanco de carga RCD GROADA AC220V 40kWes un dispositivo de prueba de última generación diseñado para simular cargas resistivas, capacitivas e inductivas complejas. Proporciona a los ingenieros de sistemas de energía y gerentes de instalaciones una solución fiable para verificar el rendimiento, la estabilidad y la resiliencia del sistema en condiciones de funcionamiento del mundo real. Este banco de carga es ideal paraSistemas UPS, inversores, generadores, centros de datos y otra infraestructura críticagarantizando operaciones ininterrumpidas y una calidad óptima de energía.
| Características | Especificación |
|---|---|
| Potencia nominal | 40 kW |
| Voltaje | CA 220V |
| Tipo de carga | RCD (Resistivo, Capacitivo, Inductivo) |
| Rango del factor de potencia | 0.6 – 1.0 |
| Frecuencia | 50/60 Hz |
| Maximum Current | 180A |
| Método de enfriamiento | Forced Air Cooling |
| Interfaz de control | Advanced Touchscreen with Real-Time Monitoring |
| Características de seguridad | Overload Protection, RCD Protection, Emergency Shutdown |
ElRCD load configuration allows precise simulation of nonlinear electrical loads, enabling engineers to test how systems behave under realistic conditions. Its high-current capacity and adjustable power factor ensure flexibility in testing a wide range of equipment.
The GROADA AC220V 40kW RCD Load Bank is engineered for versatility across multiple industries:
UPS Systems Testing
Evaluate uninterruptible power supplies under varying load conditions to ensure they can handle dynamic energy demands and maintain output stability.
Inverter Performance Validation
Test inverters in renewable energy setups and industrial environments to measure response under non-linear loads.
Data Center Power Resilience
Simulate realistic IT load profiles to verify critical infrastructure can sustain operations during peak and fluctuating demand.
Generator Load Testing
Accurately simulate complex load patterns to ensure standby and emergency generators operate reliably under non-linear conditions.
Industrial Power Systems
Analyze the impact of resistive, inductive, and capacitive loads on industrial motor drives, switchgear, and electrical distribution systems.
The GROADA RCD Load Bank is built to meet global industry standards, ensuring safe, accurate, and reliable testing:
IEEE 1547 – Interconnection of distributed resources with electric power systems
NFPA 110 – Emergency and standby power system standards
ISO 8528-10 – Load acceptance procedures for generating sets
IEC 62040 – Performance and testing requirements for uninterruptible power systems
These certifications reflect the highest level of reliability, safety, and industry compliance, making it suitable for both commercial and industrial applications.
The load bank’s advanced design allows for in-depth testing scenarios:
Dynamic Load Simulation
Test power systems’ response to rapid load changes, simulating real-life operational conditions.
Harmonic Distortion Analysis
Evaluate how non-linear loads affect voltage quality, equipment performance, and system efficiency.
Transient Response Testing
Assess system stability during sudden changes, ensuring critical power systems maintain operational continuity.
Comprehensive Load Management
Adjust resistive, inductive, and capacitive components independently to replicate a wide range of load behaviors.
Simulación de carga de precisión – Accurately replicates real-world nonlinear electrical loads for comprehensive system testing.
Interfaz fácil de usar – Intuitive touchscreen control with real-time monitoring simplifies operations and improves testing efficiency.
Robust Safety Mechanisms – Integrated protections safeguard both personnel and equipment during rigorous testing.
Versatile Industrial Applications – Suitable for data centers, renewable energy, industrial plants, and more.
Global Standards Compliance – Provides assurance of testing reliability and performance consistency across regions.
Investing in the GROADA RCD Load Bank ensures your critical power systems are rigorously tested, optimized, and ready for reliable operation under complex electrical loads. It is an indispensable tool for engineers, technicians, and facility managers seeking accuracy, safety, and efficiency in power system evaluation.