Banco de carga RCD

GROADA-AC380V-60KW-R/RCD Banco de carga Proveedor

★★★★★
Productos principales:
  • Banco de carga de CA: R / RL / RLC / RCD
  • Banco de carga de corriente continua: DC5V - 2000V, 0A - 5000A


modeloAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V-30KW-RCDAC380V-50KW-RCDAC380V-60KW-RCDAC380V-100KW-RCDAC380V-200KW-RCD
Potencia nominalR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Corriente de entrada0-22A0-45A0-45A0-90A0-45A0-300A0-450A0-600A0-750A
Tamaño (ancho * profundidad * altura mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Peso50 kg80 kg100 kg130 kg200 kg300 kg350kg450 kg550kg
Voltaje de entradaAC220 / 230VAC380 / 400V
Otro voltaje de entrada se puede personalizar según los requisitos
Carga mínima100W100W100W100W100W1 KW1 KW1 KW1 KW
Otra potencia mínima de carga se puede personalizar según los requisitos
Precisión general3% (otros requisitos de precisión se pueden personalizar según los requisitos)
factor de potenciaPF = 0,6 ~ 1,0
coeficiente de pico2 a 3
Modo de controlManual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera)
Interfaz remotaRS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos)
Función de protecciónProtección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente)
Fuente de alimentación de trabajoAC220VAC220V / AC380V
Precisión de la pantallaNivel 0,5 (otra precisión explícita se puede personalizar según los requisitos)
Parámetros de visualizaciónVoltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos)
De manera segura fríaEntrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos)
Nivel de protecciónIP20 (otro nivel de protección se puede personalizar según los requisitos)
Color de aparienciaRAL7035 (otros colores se pueden personalizar según los requisitos)
Temperatura de trabajo-10 ℃ ~ 55 ℃
Humedad relativa ≤95% RH
Altitud ≤ 2500 m



Banco de carga GROADA AC380V 60KW R / RCD - Solución avanzada de prueba de potencia

Descripción general

ElBanco de carga GROADA AC380V 60KW R / RCDes un dispositivo de prueba de potencia de grado profesional diseñado para la evaluación fiable y precisa de los sistemas de energía eléctrica. CombinarCargas resistivas, reactivas y capacitivas (R/RCD)en una única unidad, este banco de carga permite a los ingenieros y técnicos simular condiciones operacionales del mundo real. Es ideal parageneradores, sistemas UPS e infraestructura de energía industrialgarantizando un rendimiento y seguridad óptimos en diversos escenarios de carga.

Diseñado para la precisión y la durabilidad, este banco de carga cumple con rigurosos estándares industriales y proporciona unaSolución robusta para pruebas, mantenimiento y verificación del sistema.


Características clave

1. Simulación de carga completa

  • Combines resistive, reactive, and capacitive loads to replicate the performance of modern electronic equipment and complex power systems.

  • Soportareal-world testing for generators, UPS, and critical power systems, ensuring reliability under dynamic load conditions.

2. Capacidad de alta potencia

  • Delivers 60KW of total load capacity, suitable for medium to large-scale industrial applications.

  • Can handle a variety of load configurations, providing flexibility for diverse testing requirements.

3. Precision Voltage Compatibility

  • Optimizado paraAC380V systems, with customizable voltage options for international applications.

  • Ensures accurate simulation for different electrical standards, enhancing testing efficiency.

4. Advanced Control and Monitoring

  • Equipped with a digital control panel for real-time monitoring of voltage, current, power, and load distribution.

  • Allows precise adjustment of load levels, supporting step-load testing, ramp testing, and continuous load testing.

5. Safety-First Design

  • Features overcurrent, overvoltage, and thermal protection mechanisms, safeguarding both the device and the system under test.

  • Incorporates emergency shutdown and fault detection to minimize operational risk.


Aplicaciones

The GROADA AC380V 60KW R/RCD Load Bank is designed for a wide array of critical applications:

  • Prueba del generador: Validate generator capacity and performance under controlled resistive, reactive, and capacitive loads.

  • UPS System Verification: Evaluate the reliability and efficiency of uninterruptible power supplies in real-world scenarios.

  • Data Center Maintenance: Ensure uninterrupted operation of critical IT infrastructure by simulating peak and variable loads.

  • Industrial and Commercial Power Systems: Test power grids, substations, and industrial machinery for stability and efficiency.


Industry Insights

Elglobal load bank market is growing steadily due to the increasing demand for reliable and uninterrupted power solutions. According to market research, the sector is expected to expand from $300 million in 2025 to over $387 million by 2032, driven by the proliferation of data centers, renewable energy integration, and industrial automation.

Modern load banks are evolving with trends such as:

  • Modular designs for scalable testing solutions.

  • Digital monitoring for precise and automated load management.

  • Networked load banks for synchronized testing across multiple units.

  • Energy-efficient components reducing operational costs and environmental impact.

The GROADA R/RCD Load Bank incorporates these trends, delivering a cutting-edge testing tool that is both versatile and future-proof.


Why Choose GROADA Load Banks?

  1. Proven Expertise: Decades of experience in manufacturing industrial-grade load banks.

  2. Customization: Tailored solutions to meet specific load testing requirements.

  3. Reliability: Built for long-term durability and consistent performance in demanding environments.

  4. Comprehensive Support: End-to-end guidance, including installation, calibration, and technical troubleshooting.


Conclusion

For engineers and facility managers seeking a high-precision, reliable, and versatile load testing solution, the Banco de carga GROADA AC380V 60KW R / RCD delivers unmatched performance. By simulating real-world load conditions, it ensures that generators, UPS systems, and industrial power networks operate safely and efficiently, reducing downtime and safeguarding critical infrastructure.

Nuestro producto