| modelo | AC220V-10KVA-RL | AC380V-30KVA-RL | AC380V-60KVA-RL | AC380V-100KVA-RL | AC380V-300KVA-RL | AC380V-500KVA-RL | AC380V-1000KVA-RL |
| Potencia nominal | RL = 10KVA | RL = 30KVA | RL = 60KVA | RL = 100KVA | RL = 300KVA | RL = 500KVA | RL = 1000KVA |
| R = 10KW; L = 6KVA | R = 30KW; L = 18KVA | R = 60KW; L = 36KVA | R = 100KW; L = 60KVA | R = 300KW; L = 180KVA | R = 500KW; L = 300KVA | R = 1000KW; L = 600KVA | |
| Corriente de entrada | 0-45A | 0-45A | 0-90A | 0-150A | 0-450A | 0-750A | 0-1500A |
| Tamaño (ancho * profundidad * altura mm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| Peso | 25 kg | 40 kg | 80 kg | 130 kg | 250 kg | 550kg | 750 kg |
| Carga mínima | 100W | 100W | 100W | 500W | 1 KW | 5KW | 10KW |
| Otra potencia mínima de carga se puede personalizar según los requisitos | |||||||
| Voltaje de entrada | AC220 / 230V | AC380 / 400V | |||||
| Otro voltaje de entrada se puede personalizar según los requisitos | |||||||
| factor de potencia | PF = 0,8/1,0 (otro factor de potencia se puede personalizar según los requisitos) | ||||||
| Precisión general | 3% (otros requisitos de precisión se pueden personalizar según los requisitos) | ||||||
| Modo de control | Manual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera) | ||||||
| Interfaz remota | RS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos) | ||||||
| Función de protección | Protección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente) | ||||||
| Fuente de alimentación de trabajo | AC220V | AC220V / 380V | AC380V | ||||
| Precisión de la pantalla | Nivel 0,5 (otra precisión explícita se puede personalizar según los requisitos) | ||||||
| Parámetros de visualización | Voltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos) | ||||||
| De manera segura fría | Entrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos) | ||||||
| Nivel de protección | IP20 (otro nivel de protección se puede personalizar según los requisitos) | ||||||
| Color de apariencia | RAL7035 (otros colores se pueden personalizar según los requisitos) | ||||||
| Temperatura de trabajo | -10 ℃ ~ 55 ℃ | ||||||
| Humedad relativa | ≤95% RH | ||||||
| Altitud | ≤ 2500 m | ||||||
ElGROADA AC 346V 50 kVA RL Banco de cargaes un sistema de prueba de alta precisión diseñado para simular amboscargas resistivas e inductivaspara generadores, sistemas UPS, turbinas y redes eléctricas.
Con un factor de potencia de0,8 retrasoEsta unidad reproduce con precisión las condiciones de carga del mundo real, lo que permite a los ingenieros verificar el rendimiento, detectar debilidades y prevenir fallas antes de que ocurran.
Construido paraindustrial, marine, data center, and energy applications, the GROADA RL Load Bank combines advanced control technology, modular construction, and robust safety systems—delivering consistent, repeatable, and safe load testing results in any environment.
Simulates both resistive and inductive components simultaneously, providing a realistic representation of motor-driven and transformer-based systems.
Offers resistive-only, inductive-onlyocombined RL operation for flexible testing modes.
Ideal for generator commissioning, factory acceptance testing (FAT), UPS maintenance, and system validation under lagging power factor conditions.
Helps ensure that your equipment performs efficiently under real operational demands—not just laboratory conditions.
Fine-tuned load step increments (e.g., 1 kW / 1 kVAR) for accurate load adjustment and gradual system ramp-up.
Modular resistive and inductive sections allow independent operation, easy calibration, and simplified servicing.
Parallel connection capability enables capacity expansion beyond 50 kVA for large-scale test systems.
Ensures smooth, stable transitions during load switching—reducing stress on test subjects and extending lifespan.
Integrated digital PLC control system with high-precision data acquisition.
Real-time display and recording of voltage, current, power, power factor, frequency, and temperature.
Optional remote control and data logging via Ethernet / RS485 / wireless interfaces.
Automated test sequences with programmable ramp rates, dwell times, and step loads—ideal for repetitive testing and certification workflows.
Safety interlocks prevent unintended operation during testing or maintenance.
Heavy-duty, powder-coated steel enclosure ensures durability and corrosion resistance in harsh environments.
Designed for indoor or outdoor operation, with high-efficiency forced-air cooling and thermostatically controlled fans.
All circuits are fully protected by overload breakers, fuses, and fault-detection systems.
Equipped with over-temperature, airflow failure, overload, emergency-stop, and load-dump protection mechanisms.
Engineered to operate continuously at full load without performance degradation, ensuring long service life and stable accuracy.
Regular load bank testing prevents wet stacking—the accumulation of unburned fuel and carbon deposits in diesel engines.
By simulating realistic load conditions, it ensures complete combustion and optimal generator efficiency.
Detects voltage drops, connection issues, insulation degradation, and cooling inefficiencies before they cause failures.
Essential for routine preventive maintenance in telecom, healthcare, data centers, and utility power plants.
Built to meet or exceed international electrical and safety standards.
Each GROADA load bank undergoes full functional testing, calibration, and quality assurance before shipment.
Optional CE / ISO / UL-ready configurations available for compliance with global certification requirements.
Backed by GROADA’s comprehensive after-sales support, including commissioning assistance, spare parts supply, training, and remote diagnostics.
| Parámetro | Especificación |
|---|---|
| modelo | AC 346V 50 kVA RL Load Bank |
| Rated Capacity | 50 kVA (resistive + inductive) |
| Voltaje | AC 346 V (3-phase, 50/60 Hz) |
| Factor de potencia | 0.8 (lagging) |
| Load Steps | 1 kW / 1 kVAR increments (customizable) |
| Método de enfriamiento | Forced air cooling with automatic fan control |
| Protection | Over-temperature, airflow fault, overcurrent, emergency stop, short-circuit, load-dump |
| Opciones de control | Local control panel / Remote PLC / Network control |
| Enclosure Rating | Weatherproof (IP54 / NEMA 3R optional) |
| Operating Environment | Indoor / Outdoor – -10 °C to +50 °C |
| Construcción | Galvanized steel with powder coating |
| Modularity | Expandable capacity with parallel units |
The GROADA AC 346V 50 kVA RL Load Bank is engineered for a broad range of industrial and mission-critical applications, including:
Generator commissioning and maintenance
Validate generator output, voltage regulation, and governor response under full load.
UPS and inverter testing
Simulate both linear and reactive loads to confirm backup system reliability.
Transformer and switchgear evaluation
Test equipment under realistic load and power factor conditions.
Data center and telecom infrastructure
Conduct performance and redundancy tests for critical power systems.
Marine and offshore platforms
Verify generator performance in remote or sea-borne installations.
Industrial process power systems
Assess electrical infrastructure before live production.
Experience: Years of specialized manufacturing in resistive and reactive load banks for international markets.
Expertise: Engineering team experienced in generator testing, industrial automation, and electrical system design.
Authority: Products conform to global standards and are deployed across power generation, defense, oil & gas, and data center sectors.
Trustworthiness: Proven field performance, factory quality control, and strong after-sales technical support.
Every GROADA load bank is a reflection of our commitment to innovation, precision, and reliability. We work closely with OEMs, service contractors, and system integrators to deliver tailored power-testing solutions worldwide.
Electrical testing involves high energy levels and potential hazards. GROADA ensures every RL Load Bank is designed with multi-layer protection, adhering to the latest international safety directives.
All units are subjected to full-load endurance tests, insulation verification, and thermal stability trials prior to delivery—ensuring your system operates safely, efficiently, and within specification throughout its life cycle.
GROADA offers complete post-delivery services, including:
On-site installation and commissioning support
Operator training and technical documentation
Calibration and periodic inspection programs
Spare parts availability and rapid global logistics
Remote technical assistance and diagnostics
We ensure long-term operational stability and minimum downtime, protecting your investment and productivity.
Ensure your power systems are always ready for real-world performance.
Contact GROADA today to discuss your AC 346V 50 kVA RL Load Bank requirements, request a quotation, or schedule an engineering consultation.