Banco de carga AC

Banco de carga trifásico GROADA-AC415V-6KW-RLC

★★★★★
Productos principales:
  • Banco de carga de CA: R / RL / RLC / RCD
  • Banco de carga de corriente continua: DC5V - 2000V, 0A - 5000A


modeloAC220V-10KVA-RLCAC380V-30KVA-RLCAC380V-60KVA-RLCAC380V-100KVA-RLCAC380V-200KVA-RLCAC380V-300KVA-RLC
Potencia nominalRLC = 10KVARLC = 30KVARLC = 60KVARLC = 100KVARLC = 200KVARLC = 300KVA
R = 10KW; L = 10KVA
C = 10KVA
R = 30KW; L = 30KVA;
C = 30KVA
R = 60KW; L = 60KVA;
C = 60KVA
R = 100KW; L = 100KVA;
C = 100KVA
R = 200KW; L = 200KVA;
C = 200KVA
R = 300KW; L = 300KVA;
C = 300KVA
Otro poder se puede personalizar según los requisitos
Tamaño (ancho * profundidad * altura mm)500*750*1400600*850*15001000*1100*15001100*1600*15001500*1800*18002000*2000*2000
Peso120 kg380kg580 kg880 kg1500 kg2500kg
Voltaje de entradaAC220 / 230VAC380 / 400V
Otro voltaje de entrada se puede personalizar según los requisitos
Corriente de entrada0-45A0-45A0-90A0-150A0-300A0-450A
Carga mínimaR = 100W; L = 100VA;
C = 100VA
R = 100W; L = 100VA;
C = 100VA
R = 100W; L = 100VA;
C = 100VA
R = 100W; L = 100VA;
C = 100VA
R = 1KW; L = 1KVA;
C = 1KVA
R = 1KW; L = 1KVA;
C = 1KVA
Otra potencia mínima de carga se puede personalizar según los requisitos
factor de potenciaPF = 0.1 ~ 1.0 (otro factor de potencia se puede personalizar según los requisitos)
Precisión general3% (otros requisitos de precisión se pueden personalizar según los requisitos)
Modo de controlManual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera)
Interfaz remotaRS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos)
Función de protecciónProtección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente)
Fuente de alimentación de trabajoAC220VAC220V / 380VAC380V
Precisión de la pantallaNivel 0,5 (otra precisión explícita se puede personalizar según los requisitos)
Parámetros de visualizaciónVoltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos)
De manera segura fríaEntrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos)
Nivel de protecciónIP20 (otro nivel de protección se puede personalizar según los requisitos)
Color de aparienciaRAL7035 (otros colores se pueden personalizar según los requisitos)
Temperatura de trabajo-10 ℃ ~ 55 ℃
Humedad relativa ≤95% RH
Altitud ≤ 2500 m



GROAD 1068 AC Load Bank: Advanced Power System Testing with Precision and Reliability

ElGROAD 1068 AC Load Bank represents the pinnacle of electrical load testing technology, engineered for industries where power reliability and operational efficiency are mission-critical. Designed to simulate real-world electrical loads, it ensures that generators, transformers, UPS systems, and other critical power equipment perform flawlessly under full load conditions. Whether for industrial applications, data centers, or renewable energy integration, the GROAD 1068 is the ultimate solution for comprehensive power system validation.


🌟 Key Features & Advantages

  • High-Capacity Load Simulation
    Capable of handling substantial resistive and reactive loads, the GROAD 1068 can accurately replicate real operational conditions, providing engineers with reliable insights into system performance and efficiency.

  • Advanced Digital Control Interface
    Equipped with an intuitive LCD digital control system, the load bank allows for precise load adjustments, real-time monitoring, and detailed data logging. Operators can track voltage, current, and power metrics to ensure accurate testing.

  • Versatility Across Applications
    Suitable for testing generators, transformers, UPS systems, and emergency backup power solutions, the 1068 model adapts to a wide range of power infrastructures, making it indispensable for industrial, commercial, and critical mission applications.

  • Robust and Durable Construction
    Built from premium materials, the unit is designed for long-term durability, even under continuous heavy load testing, minimizing downtime and maintenance requirements.


⚡ Applications

The GROAD 1068 AC Load Bank is tailored to industries and environments where power stability and reliability cannot be compromised:

  • Power Generation – Validate the performance and efficiency of generators under peak load conditions to prevent system failures.

  • Centros de datos – Ensure UPS and backup generators operate seamlessly to maintain uninterrupted operations.

  • Industrial Manufacturing – Test power systems supporting critical processes to avoid costly downtime.

  • Sistemas de Energía Renovable – Evaluate the integration of solar, wind, and hybrid energy systems with conventional power grids.


📊 Technical Specifications

CaracterísticasEspecificación
Tipo de cargaResistive / Reactive
Voltaje380V ±10%
Frecuencia50/60 Hz
Método de enfriamientoEnfriado por aire
Control SystemDigital LCD display with precise load control
Características de protecciónOverload, short-circuit, over-temperature protection
Compliance StandardsISO 9001, CE, RoHS

📈 Industry Insights & Market Trends

Elglobal AC load bank market is experiencing significant growth, driven by the rising demand for reliable power testing solutions. Forecasts project the market to exceed $350 million by 2032, with a CAGR of approximately 6.5% from 2024 to 2032.

Key factors driving this growth include:

  1. Data Center Expansion – The surge in cloud computing and big data requires robust power infrastructure, increasing demand for high-quality load testing.

  2. Renewable Energy Integration – Ensuring renewable energy sources work seamlessly with existing grids necessitates advanced testing solutions.

  3. Regulatory Compliance – Stringent international standards for reliability, safety, and efficiency make comprehensive power system validation essential.


✅ Why Choose GROAD 1068 AC Load Bank?

  • Maximized Reliability – Prevent unexpected power failures with accurate load simulation that ensures systems perform under peak demand.

  • Cost Efficiency – Early detection of potential issues minimizes maintenance costs and extends the lifespan of expensive power equipment.

  • Compliance Confidence – Meets global standards and safety regulations, giving organizations peace of mind.

  • Operator-Friendly Design – The intuitive interface reduces the complexity of testing, making it accessible even to operators with minimal technical experience.


🏭 Industries Benefiting from the GROAD 1068

  • Energy & Utilities – Validate power generation and distribution systems for maximum uptime.

  • Telecomunicaciones – Guarantee uninterrupted network operations through rigorous backup system testing.

  • Healthcare – Maintain critical medical equipment and emergency power systems without disruption.

  • Defense & Military – Verify the readiness and reliability of mission-critical power infrastructure.


🔹 Conclusion

ElGROAD 1068 AC Load Bank is more than just a testing device—it is a strategic investment in reliability, efficiency, and safety. Combining advanced digital controls, high load capacity, and durable construction, it empowers industries to anticipate potential issues, optimize performance, and ensure operational continuity.

With the GROAD 1068, your power systems are tested not just for today, but for the future, delivering unmatched confidence in energy reliability.

Nuestro producto