Banco de carga RLC

GROADA-AC240V-20KW-RLC Banco de carga trifásico

★★★★★
Productos principales:
  • Banco de carga de CA: R / RL / RLC / RCD
  • Banco de carga de corriente continua: DC5V - 2000V, 0A - 5000A


modeloAC220V-10KVA-RLCAC380V-30KVA-RLCAC380V-60KVA-RLCAC380V-100KVA-RLCAC380V-200KVA-RLCAC380V-300KVA-RLC
Potencia nominalRLC = 10KVARLC = 30KVARLC = 60KVARLC = 100KVARLC = 200KVARLC = 300KVA
R = 10KW; L = 10KVA
C = 10KVA
R = 30KW; L = 30KVA;
C = 30KVA
R = 60KW; L = 60KVA;
C = 60KVA
R = 100KW; L = 100KVA;
C = 100KVA
R = 200KW; L = 200KVA;
C = 200KVA
R = 300KW; L = 300KVA;
C = 300KVA
Otro poder se puede personalizar según los requisitos
Tamaño (ancho * profundidad * altura mm)500*750*1400600*850*15001000*1100*15001100*1600*15001500*1800*18002000*2000*2000
Peso120 kg380kg580 kg880 kg1500 kg2500kg
Voltaje de entradaAC220 / 230VAC380 / 400V
Otro voltaje de entrada se puede personalizar según los requisitos
Corriente de entrada0-45A0-45A0-90A0-150A0-300A0-450A
Carga mínimaR = 100W; L = 100VA;
C = 100VA
R = 100W; L = 100VA;
C = 100VA
R = 100W; L = 100VA;
C = 100VA
R = 100W; L = 100VA;
C = 100VA
R = 1KW; L = 1KVA;
C = 1KVA
R = 1KW; L = 1KVA;
C = 1KVA
Otra potencia mínima de carga se puede personalizar según los requisitos
factor de potenciaPF = 0.1 ~ 1.0 (otro factor de potencia se puede personalizar según los requisitos)
Precisión general3% (otros requisitos de precisión se pueden personalizar según los requisitos)
Modo de controlManual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera)
Interfaz remotaRS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos)
Función de protecciónProtección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente)
Fuente de alimentación de trabajoAC220VAC220V / 380VAC380V
Precisión de la pantallaNivel 0,5 (otra precisión explícita se puede personalizar según los requisitos)
Parámetros de visualizaciónVoltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos)
De manera segura fríaEntrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos)
Nivel de protecciónIP20 (otro nivel de protección se puede personalizar según los requisitos)
Color de aparienciaRAL7035 (otros colores se pueden personalizar según los requisitos)
Temperatura de trabajo-10 ℃ ~ 55 ℃
Humedad relativa ≤95% RH
Altitud ≤ 2500 m


GROADA AC240V-20KW RLC Three-Phase Load Bank – Precision Load Testing for Modern Power Systems

ElGROADA AC240V-20KW RLC Three-Phase Load Bank is a high-performance electrical testing instrument designed to deliver precise, reliable, and versatile load testing for a wide range of applications. Engineered to meet the rigorous demands of industrial, commercial, and utility power systems, this load bank provides an essential solution for testing generators, UPS systems, data centers, and renewable energy installations.

With a combination of resistive, inductive, and capacitive load capabilities, the GROADA RLC load bank ensures accurate simulation of real-world power conditions, enabling operators to evaluate system performance, verify stability, and identify potential issues before they lead to costly downtime.


Características clave

1. Comprehensive Load Testing

  • Soportaresistive (R), inductive (L), and capacitive (C) loads, enabling realistic simulation of electrical system behavior under various operational conditions.

  • Compatible with single-phase and three-phase systems, making it suitable for a broad spectrum of industrial and commercial applications.

2. High-Precision Control

  • Proporcionaadjustable load steps for gradual and accurate load application.

  • Integrated digital display and monitoring system allows real-time measurement of voltage, current, power, and power factor.

  • ±0.5% output accuracy ensures precise performance testing, reducing errors in system evaluation.

3. Robust and Durable Construction

  • Construido conhigh-quality industrial-grade materials to withstand continuous operation under demanding conditions.

  • Compact and portable design with ventilated housing ensures optimal heat dissipation and long-term reliability.

4. Advanced Safety Features

  • Equipped with overload, over-voltage, and over-temperature protection to safeguard both operators and equipment.

  • Emergency stop and automatic shutdown functions provide enhanced operational safety.

5. User-Friendly Operation

  • Intuitive control panel with clear digital indicators simplifies setup and reduces operator learning curves.

  • Lightweight, mobile design with casters for easy deployment across multiple testing sites.


Applications Across Industries

Centros de datos

  • Conducts routine load testing to ensure uninterrupted power supply.

  • Validates UPS performance to minimize the risk of data loss or service interruptions.

Power Generation

  • Verifies generator output under full-load conditions.

  • Tests transformer capacity, stability, and efficiency in a controlled environment.

Sistemas de Energía Renovable

  • Evaluates solar inverters, wind turbines, and hybrid energy systems.

  • Ensures consistent power delivery and system reliability.

Industrial & Commercial Facilities

  • Assesses backup power and critical systems to prevent downtime.

  • Supports preventive maintenance and commissioning of new electrical installations.


Market Insights

Elglobal load bank market is experiencing steady growth, projected to reach approximately USD 1.9 billion by 2033, expanding at a CAGR of 6.5% from 2026 to 2033. This growth is fueled by increasing demand for reliable power systems, rigorous regulatory compliance, and the growing adoption of renewable energy systems that require precise load simulation and testing.


Why Choose GROADA AC240V-20KW RLC Load Bank?

  • Accurate & Reliable Testing: High-precision load simulation ensures realistic and reproducible results.

  • Versatile Applications: Suitable for AC and DC systems, three-phase or single-phase, resistive, inductive, and capacitive loads.

  • Enhanced Operational Safety: Advanced protective features minimize risk to both equipment and operators.

  • Durable & Portable Design: Built for industrial conditions with easy mobility for on-site testing.

  • Global Standards Compliance: Designed to meet international safety and performance standards.


Conclusion

ElGROADA AC240V-20KW RLC Three-Phase Load Bank is more than just a testing instrument—it is a critical tool for ensuring system reliability, performance, and safety in modern electrical environments. Its combination of precision, versatility, and durability makes it an indispensable asset for engineers, technicians, and facility managers who require dependable power system validation.

By investing in GROADA’s RLC load bank, organizations can proactively prevent downtime, extend equipment lifespan, and optimize operational efficiency while maintaining compliance with international electrical standards.

Nuestro producto