GROADA-AC380V-150KW-RL Banco de carga resistiva
The GROADA-AC380V-150KW-RL resistive load bank is a high-performance testing device designed to simu...
| modelo | AC220V-10KVA-RL | AC380V-30KVA-RL | AC380V-60KVA-RL | AC380V-100KVA-RL | AC380V-300KVA-RL | AC380V-500KVA-RL | AC380V-1000KVA-RL |
| Potencia nominal | RL = 10KVA | RL = 30KVA | RL = 60KVA | RL = 100KVA | RL = 300KVA | RL = 500KVA | RL = 1000KVA |
| R = 10KW; L = 6KVA | R = 30KW; L = 18KVA | R = 60KW; L = 36KVA | R = 100KW; L = 60KVA | R = 300KW; L = 180KVA | R = 500KW; L = 300KVA | R = 1000KW; L = 600KVA | |
| Corriente de entrada | 0-45A | 0-45A | 0-90A | 0-150A | 0-450A | 0-750A | 0-1500A |
| Tamaño (ancho * profundidad * altura mm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| Peso | 25 kg | 40 kg | 80 kg | 130 kg | 250 kg | 550kg | 750 kg |
| Carga mínima | 100W | 100W | 100W | 500W | 1 KW | 5KW | 10KW |
| Otra potencia mínima de carga se puede personalizar según los requisitos | |||||||
| Voltaje de entrada | AC220 / 230V | AC380 / 400V | |||||
| Otro voltaje de entrada se puede personalizar según los requisitos | |||||||
| factor de potencia | PF = 0,8/1,0 (otro factor de potencia se puede personalizar según los requisitos) | ||||||
| Precisión general | 3% (otros requisitos de precisión se pueden personalizar según los requisitos) | ||||||
| Modo de control | Manual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera) | ||||||
| Interfaz remota | RS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos) | ||||||
| Función de protección | Protección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente) | ||||||
| Fuente de alimentación de trabajo | AC220V | AC220V / 380V | AC380V | ||||
| Precisión de la pantalla | Nivel 0,5 (otra precisión explícita se puede personalizar según los requisitos) | ||||||
| Parámetros de visualización | Voltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos) | ||||||
| De manera segura fría | Entrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos) | ||||||
| Nivel de protección | IP20 (otro nivel de protección se puede personalizar según los requisitos) | ||||||
| Color de apariencia | RAL7035 (otros colores se pueden personalizar según los requisitos) | ||||||
| Temperatura de trabajo | -10 ℃ ~ 55 ℃ | ||||||
| Humedad relativa | ≤95% RH | ||||||
| Altitud | ≤ 2500 m | ||||||
ElGROADA AC380V 200 kW RL Banco de carga resistivo-reactivoes un instrumento de prueba de grado profesional diseñado paragrupos generadores, sistemas UPS, centros de datos, sistemas de energía marina y proyectos de puesta en marcha eléctrica.
ProporcionaSimulación de carga resistiva e inductiva (típicamente 0,8 factor de potencia retrasado), asegurando unprueba completa y realistasistemas eléctricos en condiciones de funcionamiento reales.
Construido concomponentes de grado industrialysistemas de medición de alta precisiónEsta unidad ofrece un rendimiento estable, seguro y repetible para la validación de potencia crítica.
Soportaresistente (1.0 PF)yresistivo + inductivo (0,8 PF)operación.
Ideal para simular características eléctricas del mundo real de motores, transformadores y cargas inductivas.
Permite a los usuarios analizar la estabilidad del sistema, el factor de potencia y la regulación de voltaje en condiciones de tensión realistas.
Precisión de salida hasta±0.5%garantiza resultados de prueba fiables.
El control de carga paso a paso permite un aumento gradual y seguro de la potencia.
Monitoreo continuo devoltaje, corriente, potencia y PFpara la recopilación precisa de datos.
Protección integrada:sobrecarga, sobretemperatura, cortocircuito, and fan failure alarm.
Modular resistor and inductor assemblies simplify inspection and service.
Compact cabinet design suitable for laboratory, plant room, or field testing environments.
High-efficiency air cooling system maintains stable operation under continuous load.
Optional remote monitoring system for data acquisition and real-time control.
Intuitive control interface with touch screen or switch panel.
Supports parallel operation with other load banks for expanded capacity.
| Parámetro | Especificación |
|---|---|
| Potencia nominal | 200 kW |
| Voltaje nominal | 380 V AC, 3-phase |
| Factor de potencia | 1.0 (resistive) / 0.8 (inductive) |
| Load Step | Customizable (e.g. 5 kW or 10 kW per step) |
| Accuracy | ±0.5% |
| Refrigeración | Forced air cooling |
| Protection | Overload, over-temperature, short circuit |
| Operating Temperature | –20 °C to +50 °C |
| Enclosure | Indoor/Outdoor, IP54 |
| Modo de control | Local / Remote |
| Data Interface | Optional RS485 / Ethernet / MODBUS |
Generator commissioning and performance validation
UPS and inverter testing in data centers and telecom facilities
Periodic maintenance to prevent generator wet stacking
Marine power system simulation and verification
Load sharing and synchronization tests for parallel generators
Factory acceptance tests (FAT) and on-site commissioning
Comprehensive testing for both real and reactive load performance
Improved power factor analysis for optimizing generator performance
Enhanced safety through automated protections and precision control
Global standard compliance (IEC, GB, ISO) ensuring international reliability
Engineered by professionals with years of expertise in load testing and power simulation
According to recent industry reports, the global load bank market is projected to grow from USD 288 million in 2024 to USD 387 million by 2032, driven by the expansion of data centers, renewable energy systems, and industrial backup power solutions.
The demand for resistive-reactive load banks is especially increasing, as more users seek to replicate realistic electrical environments for accurate generator and UPS testing.
This market trend highlights the value of GROADA’s advanced RL load bank solutions, which combine high precision, flexible configuration, and durable performance for modern power infrastructure projects.
Connect the load bank to your generator or UPS system securely.
Perform no-load checks for voltage and frequency stability.
Gradually apply load steps (resistive or inductive) up to the desired level.
Monitor system response — voltage, current, PF, and temperature.
Record test data for analysis and maintenance documentation.
After testing, reduce load to zero and allow cooling fans to run for several minutes.
Inspect components before disconnecting and storage.
Over 10 years of engineering expertise in power testing equipment
Customizable solutions from 10 kW to 5 MW load capacity
Exported to over 50 countries worldwide
Supported by a dedicated technical and after-sales service team
Proven reliability in harsh industrial and offshore environments
GROADA’s mission is to provide trusted and innovative load testing solutions that ensure safety, stability, and efficiency for global power systems.
Q1: What does RL mean in load banks?
RL means Resistive + Inductive. It combines resistive elements that draw real power (kW) and inductive coils that draw reactive power (kVAR), simulating real-world electrical loads with lagging power factor.
Q2: Why is reactive load testing important?
Reactive testing helps evaluate generator voltage regulation, power factor correction capability, and transient response — critical factors for reliable system operation.
Q3: Can GROADA RL load banks operate outdoors?
Yes, optional weatherproof enclosures (IP54/IP55) make them suitable for outdoor or mobile applications.
Q4: Can multiple load banks be paralleled?
Yes, GROADA RL load banks can be connected in parallel to achieve higher power capacity or multi-system testing.
Q5: How often should load bank testing be done?
Industry best practice recommends at least once a year for standby generators or UPS systems to ensure reliable performance and avoid carbon buildup.
GROADA is a professional manufacturer of industrial load banks and power testing equipment.
We specialize in resistive, inductive, capacitive, and combined load banks from 10 kW to 5 MW, serving industries such as energy, telecom, marine, and manufacturing.
Our products are exported globally and recognized for quality, durability, and engineering precision.
Every GROADA load bank is designed to meet international standards (IEC/GB) and undergoes strict factory testing to ensure optimal performance.