Banque de charge

Banque de charge d'onduleur GROADA-AC600V-25KW-RCD

★★★★★
Produits principaux :
  • Banque de charge AC : R / RL / RLC / RCD
  • Banque de charge DC : DC5V - 2000V, 0A - 5000A


ModèleAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V-30KW-RCDAC380V-50KW-RCDAC380V-60KW-RCDAC380V-100KW-RCDAC380V-200KW-RCD
Puissance nominaleR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Courant d'entrée0 à 22A0 à 45A0 à 45A0 à 90A0 à 45A0 à 300A0 à 450A0 à 600A0 à 750A
Taille (largeur * profondeur * hauteur mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Poids50 kg80 kg100 kilogrammes130 kg200 kg300 kg350kg450 kg550kg
Tension d'entréeAC220 / 230VAC380 / 400V
Autre tension d'entrée peut être personnalisée selon les exigences
Chargement minimum100 watts100 watts100 watts100 watts100 watts1 kilowatt1 kilowatt1 kilowatt1 kilowatt
Autre puissance de charge minimale peut être personnalisée selon les exigences
Précision globale3% (autres exigences de précision peuvent être personnalisées selon les exigences)
facteur de puissancePF = 0,6 ~ 1,0
coefficient de pic2 à 3
Mode de commandeOrdinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin)
Interface à distanceRS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences)
Fonction de protectionProtection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant)
Alimentation électrique de travailAC220VAC220V / AC380V
Précision de l'affichageNiveau 0,5 (autre précision explicite peut être personnalisée selon les exigences)
Paramètres d'affichageVoltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences)
Froid façon sûreEntrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences)
Niveau de protectionIP20 (autre niveau de protection peut être personnalisé selon les exigences)
Couleur d'apparenceRAL7035 (autres couleurs peuvent être personnalisées selon les exigences)
Température de travail-10 ℃ ~ 55 ℃
Humidité relative ≤95% RH
Altitude ≤ 2500 m


GROADA AC600V-25kW RCD Load Bank – Precision AC Power Testing Solution

Aperçu du produit

LeGROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-world electrical loads for generators, UPS systems, power inverters, and other electrical equipment. By accurately replicating resistive, inductive, and capacitive loads, it enables engineers to verify system performance, stability, and safety under various operating conditions.

Key Features:

  • High Voltage Compatibility – Supports up to AC 600V for medium- and high-voltage testing.

  • 25kW Adjustable Load – Flexible load steps to simulate multiple scenarios.

  • RCD Safety Protection – Built-in Residual Current Device ensures operator and equipment safety.

  • Modular & Scalable – Easily expandable for higher capacity applications.

  • User-Friendly Control – Digital interface with local and remote monitoring options.


Spécifications techniques

ItemSpécification
ModèleAC600V-25kW RCD
Tension nominale0–600V AC
Puissance nominale25kW
Type de chargeResistive / Inductive / Capacitive
Control OptionsDigital / Manual / Remote interface
Accuracy±0.5%
Méthode de refroidissementForced air cooling (optional water cooling)
Safety ProtectionOverload, short-circuit, grounding, RCD protection
Dimensions / Weight(Customize according to actual model)

Industry Insights & Market Trends

Load banks have become an essential tool in power reliability testing, especially for data centers, power plants, and mission-critical facilities.

  • Leglobal load bank market was valued at USD 288.17 million in 2024 and is projected to grow at a CAGR of 3.7% through 2032.

  • Another report estimates the market will reach USD 303.2 million by 2025 and USD 412.9 million by 2032 (CAGR ~4.5%).

  • North America accounted for over USD 106 million in 2024, maintaining steady growth.

  • Emerging trends include modular design, automated testing, hybrid load simulation (resistive + inductive), and remote monitoring solutions.

With years of expertise, GROADA integrates these cutting-edge technologies into our products, ensuring reliable, efficient, and safe load testing solutions for global customers.


Typical Applications

  • Generator set performance testing and commissioning

  • UPS and battery system capacity verification

  • Inverter and VFD (Variable Frequency Drive) load response testing

  • Power equipment troubleshooting and preventive maintenance

  • Data center and critical power system validation


Case Studies

  • Power Plant Commissioning – A major utility company used the AC600V-25kW load bank to validate standby generator systems under 90% load, ensuring stable power delivery.

  • Data Center Validation – A Tier-III data center successfully simulated peak load conditions to test UPS redundancy and battery response.

  • Industrial Project – During factory acceptance testing, our load bank enabled engineers to simulate real operating conditions, reducing post-installation faults.


Operation & Safety Guidelines

Operation Steps:

  1. Verify system voltage compatibility.

  2. Connect grounding and safety wiring.

  3. Interface with local or remote control system.

  4. Gradually apply load steps and monitor parameters.

Safety Precautions:

  • Do not exceed rated load and voltage range.

  • Always ensure proper grounding.

  • Only qualified personnel should operate.

  • Inspect wiring, fans, and resistors regularly.

Maintenance Recommendations:

  • Keep ventilation unobstructed.

  • Clean dust and debris periodically.

  • Perform annual calibration to maintain accuracy.

  • Avoid continuous operation at full load for extended periods.


Frequently Asked Questions (FAQ)

Q1: What is an AC load bank?
A: An AC load bank simulates electrical loads to test power sources such as generators and UPS systems, ensuring they can perform reliably under real operating conditions.

Q2: Why is RCD protection important?
A: The built-in Residual Current Device (RCD) disconnects the circuit in case of leakage current, providing essential safety in high-voltage environments.

Q3: Is 25kW suitable for my application?
A: If your system requires up to 25kW testing at 600V, this model is ideal. For higher power requirements, multiple units can be connected in parallel.

Q4: What is the accuracy of this load bank?
A: It delivers precision testing with a load accuracy of ±0.5%, ensuring reliable measurement results.

Q5: Can I request a customized model?
A: Yes, GROADA offers customized high-power, modular, or multi-channel load banks tailored to specific project needs.


Certifications & Quality Assurance

  • Built under ISO 9001 certified quality management system

  • CE / IEC / UL compliance available (model dependent)

  • Calibration and third-party test reports provided on request

  • Standard 12-month warranty with extended service options

  • Lifetime technical support and fast response service


Why Choose GROADA?

  • Over 10 years of engineering experience in load bank manufacturing

  • Trusted by customers in power generation, aerospace, data centers, and renewable energy sectors

  • Proven track record with successful projects worldwide

  • Dedicated R&D team providing cutting-edge testing solutions

Notre produit