Banque de charge d'onduleur GROADA-AC600V-25KW-RCD
La banque de charge RCD GROADA AC600V-25kW est un dispositif de test professionnel conçu pour simuler le monde réel. ..
| Modèle | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| Puissance nominale | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Courant d'entrée | 0 à 22A | 0 à 45A | 0 à 45A | 0 à 90A | 0 à 45A | 0 à 300A | 0 à 450A | 0 à 600A | 0 à 750A |
| Taille (largeur * profondeur * hauteur mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Poids | 50 kg | 80 kg | 100 kilogrammes | 130 kg | 200 kg | 300 kg | 350kg | 450 kg | 550kg |
| Tension d'entrée | AC220 / 230V | AC380 / 400V | |||||||
| Autre tension d'entrée peut être personnalisée selon les exigences | |||||||||
| Chargement minimum | 100 watts | 100 watts | 100 watts | 100 watts | 100 watts | 1 kilowatt | 1 kilowatt | 1 kilowatt | 1 kilowatt |
| Autre puissance de charge minimale peut être personnalisée selon les exigences | |||||||||
| Précision globale | 3% (autres exigences de précision peuvent être personnalisées selon les exigences) | ||||||||
| facteur de puissance | PF = 0,6 ~ 1,0 | ||||||||
| coefficient de pic | 2 à 3 | ||||||||
| Mode de commande | Ordinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin) | ||||||||
| Interface à distance | RS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences) | ||||||||
| Fonction de protection | Protection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant) | ||||||||
| Alimentation électrique de travail | AC220V | AC220V / AC380V | |||||||
| Précision de l'affichage | Niveau 0,5 (autre précision explicite peut être personnalisée selon les exigences) | ||||||||
| Paramètres d'affichage | Voltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences) | ||||||||
| Froid façon sûre | Entrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences) | ||||||||
| Niveau de protection | IP20 (autre niveau de protection peut être personnalisé selon les exigences) | ||||||||
| Couleur d'apparence | RAL7035 (autres couleurs peuvent être personnalisées selon les exigences) | ||||||||
| Température de travail | -10 ℃ ~ 55 ℃ | ||||||||
| Humidité relative | ≤95% RH | ||||||||
| Altitude | ≤ 2500 m | ||||||||
LeGROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-world electrical loads for generators, UPS systems, power inverters, and other electrical equipment. By accurately replicating resistive, inductive, and capacitive loads, it enables engineers to verify system performance, stability, and safety under various operating conditions.
Key Features:
High Voltage Compatibility – Supports up to AC 600V for medium- and high-voltage testing.
25kW Adjustable Load – Flexible load steps to simulate multiple scenarios.
RCD Safety Protection – Built-in Residual Current Device ensures operator and equipment safety.
Modular & Scalable – Easily expandable for higher capacity applications.
User-Friendly Control – Digital interface with local and remote monitoring options.
| Item | Spécification |
|---|---|
| Modèle | AC600V-25kW RCD |
| Tension nominale | 0–600V AC |
| Puissance nominale | 25kW |
| Type de charge | Resistive / Inductive / Capacitive |
| Control Options | Digital / Manual / Remote interface |
| Accuracy | ±0.5% |
| Méthode de refroidissement | Forced air cooling (optional water cooling) |
| Safety Protection | Overload, short-circuit, grounding, RCD protection |
| Dimensions / Weight | (Customize according to actual model) |
Load banks have become an essential tool in power reliability testing, especially for data centers, power plants, and mission-critical facilities.
Leglobal load bank market was valued at USD 288.17 million in 2024 and is projected to grow at a CAGR of 3.7% through 2032.
Another report estimates the market will reach USD 303.2 million by 2025 and USD 412.9 million by 2032 (CAGR ~4.5%).
North America accounted for over USD 106 million in 2024, maintaining steady growth.
Emerging trends include modular design, automated testing, hybrid load simulation (resistive + inductive), and remote monitoring solutions.
With years of expertise, GROADA integrates these cutting-edge technologies into our products, ensuring reliable, efficient, and safe load testing solutions for global customers.
Generator set performance testing and commissioning
UPS and battery system capacity verification
Inverter and VFD (Variable Frequency Drive) load response testing
Power equipment troubleshooting and preventive maintenance
Data center and critical power system validation
Power Plant Commissioning – A major utility company used the AC600V-25kW load bank to validate standby generator systems under 90% load, ensuring stable power delivery.
Data Center Validation – A Tier-III data center successfully simulated peak load conditions to test UPS redundancy and battery response.
Industrial Project – During factory acceptance testing, our load bank enabled engineers to simulate real operating conditions, reducing post-installation faults.
Operation Steps:
Verify system voltage compatibility.
Connect grounding and safety wiring.
Interface with local or remote control system.
Gradually apply load steps and monitor parameters.
Safety Precautions:
Do not exceed rated load and voltage range.
Always ensure proper grounding.
Only qualified personnel should operate.
Inspect wiring, fans, and resistors regularly.
Maintenance Recommendations:
Keep ventilation unobstructed.
Clean dust and debris periodically.
Perform annual calibration to maintain accuracy.
Avoid continuous operation at full load for extended periods.
Q1: What is an AC load bank?
A: An AC load bank simulates electrical loads to test power sources such as generators and UPS systems, ensuring they can perform reliably under real operating conditions.
Q2: Why is RCD protection important?
A: The built-in Residual Current Device (RCD) disconnects the circuit in case of leakage current, providing essential safety in high-voltage environments.
Q3: Is 25kW suitable for my application?
A: If your system requires up to 25kW testing at 600V, this model is ideal. For higher power requirements, multiple units can be connected in parallel.
Q4: What is the accuracy of this load bank?
A: It delivers precision testing with a load accuracy of ±0.5%, ensuring reliable measurement results.
Q5: Can I request a customized model?
A: Yes, GROADA offers customized high-power, modular, or multi-channel load banks tailored to specific project needs.
Built under ISO 9001 certified quality management system
CE / IEC / UL compliance available (model dependent)
Calibration and third-party test reports provided on request
Standard 12-month warranty with extended service options
Lifetime technical support and fast response service
Over 10 years of engineering experience in load bank manufacturing
Trusted by customers in power generation, aerospace, data centers, and renewable energy sectors
Proven track record with successful projects worldwide
Dedicated R&D team providing cutting-edge testing solutions