Banque de charge d'onduleur GROADA-AC600V-25KW-RCD
La banque de charge RCD GROADA AC600V-25kW est un dispositif de test professionnel conçu pour simuler le monde réel. ..
| Modèle | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V - 30KW-RCD | AC380V - 50KW-RCD | AC380V - 60KW-RCD | AC380V - 100KW-RCD | AC380V - 200KW-RCD |
| Puissance nominale | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Courant d'entrée | 0 à 22A | 0 à 45A | 0 à 45A | 0 à 90A | 0 à 45A | 0 à 300A | 0 à 450A | 0 à 600A | 0 à 750A |
| Taille (largeur * profondeur * hauteur mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Poids | 50 kg | 80 kg | 100 kilogrammes | 130 kg | 200 kg | 300 kg | 350kg | 450 kg | 550kg |
| Tension d'entrée | AC220 / 230V | AC380 / 400V | |||||||
| Autre tension d'entrée peut être personnalisée selon les exigences | |||||||||
| Chargement minimum | 100 watts | 100 watts | 100 watts | 100 watts | 100 watts | 1 kilowatt | 1 kilowatt | 1 kilowatt | 1 kilowatt |
| Autre puissance de charge minimale peut être personnalisée selon les exigences | |||||||||
| Précision globale | 3% (autres exigences de précision peuvent être personnalisées selon les exigences) | ||||||||
| facteur de puissance | PF = 0,6 ~ 1,0 | ||||||||
| coefficient de pic | 2 à 3 | ||||||||
| Mode de commande | Ordinateur hôte manuel local / à distance (mode de contrôle manuel local: disjoncteur / bouton / écran tactile trivial facultatif, d'autres méthodes peuvent être personnalisées au besoin) | ||||||||
| Interface à distance | RS232/RS485/USB/RJ45/CAN/GPIB (autres modes d'interface peuvent être personnalisés selon les exigences) | ||||||||
| Fonction de protection | Protection contre l'arrêt d'urgence, protection contre la surtempérature, protection contre l'interverrouillage de la charge du ventilateur, protection contre la mise à la terre (sélectionnez la protection contre la surtension, la protection contre le surcourant, la protection contre le court-circuit, la surcharge du ventilateur, le volume d'air insuffisant) | ||||||||
| Alimentation électrique de travail | AC220V | AC220V / AC380V | |||||||
| Précision de l'affichage | Niveau 0,5 (autre précision explicite peut être personnalisée selon les exigences) | ||||||||
| Paramètres d'affichage | Voltage, courant, puissance, fréquence, facteur de puissance, etc. (autres méthodes explicites peuvent être personnalisées selon les exigences) | ||||||||
| Froid façon sûre | Entrée d'air latérale et sortie d'air supérieure (d'autres méthodes de sortie d'air peuvent être personnalisées selon les exigences) | ||||||||
| Niveau de protection | IP20 (autre niveau de protection peut être personnalisé selon les exigences) | ||||||||
| Couleur d'apparence | RAL7035 (autres couleurs peuvent être personnalisées selon les exigences) | ||||||||
| Température de travail | -10 ℃ ~ 55 ℃ | ||||||||
| Humidité relative | ≤95% RH | ||||||||
| Altitude | ≤ 2500 m | ||||||||
Dans les infrastructures électriques modernes, la précision dans le test et la validation du comportement de la source dans des conditions de charge réelle est essentielle. LeBanque de charge d'onduleur AC 120V 50 kVA RCDde GROADA est conçu pour simuler des charges électriques réelles pour les systèmes d'onduleurs, d'alimentateurs courants, de générateurs et de batteries dans des conditions sûres et répétables.
En utilisant la simulation de charge résistive, réactive ou combinée, les banques de charge d'onduleur aident à révéler les problèmes latents de performance ou de stabilité avant qu'ils ne puissent avoir un impact sur les opérations. Cet appareil est particulièrement précieux pour:
Mise en service de nouveaux systèmes d'alimentation ou d'inverseurs
Entretien de routine des systèmes de stockage d'énergie
Essais de contrainte des générateurs de secours et des UPS
Assurer la conformité du système aux normes de sécurité et réglementaires
Voici une ventilation de haut niveau des fonctionnalités dont vos visiteurs se soucieront et qui aideront les moteurs de recherche à comprendre la pertinence et la profondeur de la page:
Sortie nominale:120 V AC, 50 kVA
Protection et protection des RCD sécurité :Dispositif de courant résiduel pour protéger l'opérateur et l'équipement
Fonctionnement compatible avec l'inverseur:prend en charge l'injection bidirectionnelle ou contrôlée pour imiter le comportement de l'onduleur
Contrôle précis de la charge:commande à plusieurs étapes ou continue, avec mesure précise du courant/de la tension
Refroidissement & gestion thermique : forced air cooling with intelligent fan control to manage resistor element temperature
Monitoring & communication: local display and optional remote interface (e.g. via RS-485, Ethernet, or other protocol)
Modular & maintainable design: replaceable resistor modules, easy access panels
Protection & safety features: overcurrent, overtemperature, short circuit, emergency stop
By emphasizing these aspects, the page signals both to users and to Google that it contains useful, detailed product content rather than shallow marketing fluff.
To build trust and authority, it’s useful to situate this product into its broader technical and market context:
What is a load bank?
A load bank is a device that imposes an electrical load on a power source in a controlled manner, converting that energy (usually via resistors) to heat, often dissipated by forced-air or water cooling systems. This allows engineers to test generators, UPSs, inverters, or batteries under known, stable loads without relying on unpredictable real-world load behavior.
Why inverter-compatible load banks?
Traditional resistive load banks impose static loads; inverter load banks, however, can more closely mimic dynamic power conversion behaviors (e.g. voltage drop, harmonic response) and can be used in conjunction with power electronics. This is especially relevant in modern microgrids, renewable systems, and energy storage test benches.
Market trends & demand
The global load bank market is projected to grow at a compound annual growth rate (CAGR) of ~3.7% from 2025 to 2032, expanding from ~$300 million in 2025 to ~$387 million by 2032.
Drivers include increased deployment of data centers, renewable energy integration, stricter power reliability standards, and wider use of battery/inverter systems. Enercon+1
In Asia-Pacific, especially China and India, industrial expansion and power infrastructure upgrades are accelerating demand for load testing and commissioning equipment.
By referencing these data points (with citations), the page demonstrates that the product is relevant in a growing, technology-driven sector.
To further increase relevance and user trust, lay out concrete scenarios where your product adds value:
| Application | Benefit / Use Case |
|---|---|
| Generator commissioning & acceptance testing | Verify full-load performance, thermal stability, load transient response |
| UPS & battery system verification | Confirm DC–AC inverter behavior under load, simulate real consumption profiles |
| Renewable + storage systems | During debugging/integration, impose known loads on inverter systems to test control logic |
| Maintenance & preventive testing | Routinely exercise systems to avoid “wet stacking,” carbon build-up, or capacity derating |
| Data center & mission critical facilities | Validate that backup systems can seamlessly take over under full load |
Including real user scenarios helps Google and users see your page as practically useful, boosting engagement and dwell time (factors that support SEO).
To help engineers / purchasers make informed decisions, you can include guidance or best practices:
Sizing margin: Choose a load bank with at least 20% headroom above expected maximum load to ensure longevity and safety under transient stress.
Power factor and reactance: If users need to test non-unity power factor loads (e.g. inductive or capacitive), consider combining with reactive modules or using R / L / C combination load banks.
Cooling & ambient conditions: The design must account for ambient temperature, ventilation constraints, and altitude.
Measurement accuracy: Use high-precision voltage and current sensors, with calibration, to ensure valid test data.
Safety and compliance: Design must comply with relevant electrical safety standards (e.g. IEC, UL, local codes), use proper insulation, earthing, overcurrent protection, and safe operator interface.
Maintenance tips: Periodic inspection of resistor elements, fan filters, connection integrity, insulation resistance, and firmware upgrades (if remote control is supported).
By offering this level of detail, the page becomes more than a sales pitch — it’s a resource, strengthening EEAT.
To boost trust (the “T” in EEAT), you should include or anchor (in surrounding parts of the site) elements like:
Company credentials & history: e.g. years of experience in power test / electrical load equipment manufacturing
Certifications & standards compliance: ISO, CE, UL, or others
Case studies / project references: real projects where this unit or similar ones were deployed (data centers, utility projects, etc.)
Third-party validation / testimonials: quotes from users, labs, or certifications
After-sales support & warranty: spare parts, calibration service, technical support coverage
In the body you can include a brief paragraph like:
GROADA is a specialist in power test solutions, with X years of experience designing reliable load banks. All units are factory tested, and we provide global after-sales support, spare parts, and calibration service to assure your long-term operational reliability.
Conclude with a user-focused, persuasive call to action, e.g.:
For detailed specifications, drawings, or customized configurations of the 120 V 50 kVA RCD inverter load bank, please contact our technical team. Let us help tailor a load testing solution that fits your system needs — from initial sizing to full test commissioning and long-term support.