GROADA-AC400V-30KW-RCD omvormer laadbank

★★★★★
Belangrijkste producten:
  • AC Lastbank: R/RL/RLC/RCD
  • DC Load Bank: DC5V - 2000V, 0A - 5000A

Eén: reguliere RCD AC load bank productparameters


ModelAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V - 30KW-RCDAC380V - 50KW-RCDAC380V - 60KW-RCDAC380V - 100KW-RCDAC380V - 200KW-RCD
Nominale vermogenR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Input stroom0-22A0-45A0-45A0-90A0-45A0-300A0-450A0-600A0-750A
Grootte (breedte * diepte * hoogte mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
gewicht50 kg80 kg100 kg130 kg200 kg300 kg350 kg450 kg550 kg
IngangsspanningAC220 / 230VAC380 / 400V
Andere ingangsspanning kan volgens vereisten worden aangepast
Minimale lading100W100W100W100W100W1kw1kw1kw1kw
Andere minimale laadmacht kan volgens vereisten worden aangepast
Algemene nauwkeurigheid3% (andere nauwkeurigheidsvereisten kunnen volgens vereisten worden aangepast)
vermogensfactorPF = 0,6 ~ 1,0
piekcoëfficiënt2 tot 3
Controle modusLokale handmatige/externe gastcomputer (lokale handmatige besturingsmodus: schakelaar/knop/aanraakscherm drieweg optioneel, andere methoden kunnen worden aangepast zoals vereist)
Interface op afstandRS232/RS485/USB/RJ45/CAN/GPIB (andere interfacemodies kunnen volgens vereisten worden aangepast)
BeschermingsfunctieBescherming tegen noodstop, bescherming tegen overtemperatuur, bescherming tegen ventilatorbelasting, bescherming tegen aarding (selecteer bescherming tegen overspanning, bescherming tegen overstroom, bescherming tegen kortsluiting, overbelasting van de ventilator, onvoldoende luchtvolume)
Werkende voedingAC220VAC220V / AC380V
Vertoningsnauwkeurigheid0,5 niveau (andere expliciete precisie kan volgens vereisten worden aangepast)
Weergave parametersSpanning, stroom, vermogen, frequentie, vermogensfactor, enz. (andere expliciete methoden kunnen volgens vereisten worden aangepast)
Koude zekere manierZijluchtingang en bovenluchtuitlaat (andere luchtuitlaatmethoden kunnen volgens vereisten worden aangepast)
BeschermingsniveauIP20 (andere beschermingsniveau kan volgens vereisten worden aangepast)
Kleur van uiterlijkRAL7035 (andere kleuren kunnen volgens vereisten worden aangepast)
Werktemperatuur-10 ℃ ~ 55 ℃
Relatieve vochtigheid ≤95%RH
Hoogte ≤ 2500 m


Product overview


Before running the 30kWRCD AC load bank test equipment, the following items should be paid attention to: observe the output voltage of the generator, confirm whether the output voltage is 400V, if it is 380V, the power of each gear needs to be adjusted accordingly), observe the output of the generator Power, confirm that the corresponding square cable is connected to the terminal, confirm that the appropriate grounding protection cable is connected, confirm that the inlet and exhaust channels are clean, and the site is well ventilated. Make sure that the hot air discharged from the exhaust channel does not enter the intake channel to cause circulation. Turn off the fan switch and start the fan. If the wind blows to the air inlet, the phase sequence of the power supply is connected incorrectly. Adjust the phase sequence, close the load switch, and the load indicator light will be on.


Introduction to Control System


RCD AC load bank generally comes standard with manual one-key loading, and two operation modes of local touch screen control and remote automatic control can be customized. Click the Load OK button to begin the loading process. Start the shutter, then start the fan. After inputting the air volume signal, start the load. When unloading, first disconnect the load, when the temperature drops below the preset value, stop the fan and close the shutter. It should be noted that when loading and unloading here, due to the delay signal of the shutter, it is recommended to perform the opposite operation after one program cycle, and do not start and stop frequently. If there is an alarm signal input before starting, it cannot be started. If there is an alarm signal during operation, only the load is cut off, and the fan stops running after heat dissipation.


It should be noted that after all alarms (including emergency stop) occur, the start switch (signal) needs to be reset to prevent personal injury or equipment damage caused by sudden loading after the alarm is reset.


n Product description:


WS-6400 series AC intelligent dry load can be typically applied to generator test system. Based on the traditional load test equipment, the design is optimized from the aspects of appearance design, process control, data recording, system integration and user experience, providing fully automated generator load test. The system consists of four parts: generator set auxiliary measuring and controlling instrument, generator set special measuring instrument, controller and load cabinet. It provides test items including various performance indexes of generator set, automatic load detection and test process, and generates data collection, data analysis and report. The test system is also suitable for field testing, performance certification, commissioning and acceptance of power generation units.


The load bank is RCD AC load bank, which is made of special alloy resistance winding, covered with stainless steel, has small temperature drift and long service life. The total power of a single machine is as high as 50MW. The exterior box adopts a fixed container structure, which has rainproof protection function, adopts top air outlet, is easier to dissipate heat, and has automatic overheating protection function and automatic fan fault unloading function. The load cabinet is equipped with a remote controller, which can realize remote control.


Onze producten