Banco de carga indutiva resistiva GROADA-AC346V-50KVA-RL
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet design...
| Modelo | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Potência nominal | RLC = 10KVA | RLC = 30KVA | RLC = 60KVA | RLC = 100KVA | RLC = 200KVA | RLC = 300KVA |
| R = 10KW; L = 10KVA C = 10KVA | R = 30KW; L = 30KVA; C = 30KVA | R = 60KW; L = 60KVA; C = 60KVA | R = 100KW; L = 100KVA; C = 100KVA | R = 200KW; L = 200KVA; C = 200KVA | R = 300KW; L = 300KVA; C = 300KVA | |
| Outro poder pode ser personalizado de acordo com os requisitos | ||||||
| Tamanho (largura * profundidade * altura mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Peso | 120 quilos | 380 quilos | 580 quilos | 880 quilos | 1500 quilos | 2500 quilos |
| Tensão de entrada | AC220 / 230V | AC380 / 400V | ||||
| Outra tensão de entrada pode ser personalizada de acordo com os requisitos | ||||||
| Corrente de entrada | 0-45A | 0-45A | 0-90A | 0-150A | 0-300A | 0-450A |
| Carga mínima | R = 100W; L=100VA; C = 100VA | R = 100W; L=100VA; C = 100VA | R = 100W; L=100VA; C = 100VA | R = 100W; L=100VA; C = 100VA | R = 1KW; L = 1KVA; C = 1KVA | R = 1KW; L = 1KVA; C = 1KVA |
| Outra potência mínima de carga pode ser personalizada de acordo com os requisitos | ||||||
| fator de potência | PF = 0,1 ~ 1,0 (outro fator de potência pode ser personalizado de acordo com os requisitos) | |||||
| Precisão geral | 3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos) | |||||
| Modo de controle | Manual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário) | |||||
| Interface remota | RS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos) | |||||
| Função de proteção | Proteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente) | |||||
| Fonte de alimentação de trabalho | AC220V | AC220V / 380V | AC380V | |||
| Precisão da exibição | 0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos) | |||||
| Parâmetros de exibição | Tensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos) | |||||
| Frio certa maneira | Entrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos) | |||||
| Nível de proteção | IP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos) | |||||
| cor da aparência | RAL7035 (outras cores podem ser personalizadas de acordo com os requisitos) | |||||
| Temperatura de trabalho | -10 ℃ ~ 55 ℃ | |||||
| Umidade relativa | ≤95%RH | |||||
| Altitude | ≤ 2500 m | |||||
Desbloqueie precisão, confiabilidade e versatilidade incomparáveis nos testes de sistemas de energia com oBanco de carga GROADA AC380V-20KW-RLCProjetado para profissionais dos setores de energia, indústria e renováveis, este banco de carga avançado fornece simulação precisa de carga resistiva, indutiva e capacitiva (RLC) para geradores, sistemas UPS, inversores e infraestruturas de carregamento de veículos elétricos (EV).
Se você está comissionando novos equipamentos de energia, validando o desempenho operacional ou realizando manutenção de rotina, o banco de carga AC380V-20KW-RLC oferece resultados em que você pode confiar.
Potência nominal20 kW em 380V AC
Tipo de cargaResistivo, indutivo, capacitivo (RLC)
Classificação de tensão : 380V AC
RefrigeraçãoSistema refrigerado a ar eficiente para uma gestão térmica consistente
Interface de controle: Digital panel with LED indicators displaying real-time load, voltage, current, and power factor
Mecanismos de segurança: Over-temperature protection, branch circuit fuses, and integrated sensors to prevent overload or overheating
Design & Portability: Compact, lightweight, and durable chassis, optimized for easy transport and deployment in varied environments
The RLC configuration allows for the replication of realistic electrical loads. By simulating resistive, inductive, and capacitive components, this load bank ensures your power systems are tested under true operational conditions. This capability is critical for validating generator performance, UPS reliability, and inverter efficiency. Accurate load testing minimizes the risk of system failure and reduces downtime, ensuring operational continuity for critical infrastructure.
Equipped with a sophisticated digital control panel, the AC380V-20KW-RLC Load Bank provides real-time data on all key electrical parameters. Users can monitor voltage, current, power factor, and load trends continuously. The system supports predictive maintenance and condition-based monitoring, enabling engineers to detect potential issues before they escalate, thereby enhancing equipment lifespan and reliability.
GROADA emphasizes eco-friendly design without compromising performance. The load bank’s air-cooled system reduces energy consumption while maintaining optimal testing conditions. By integrating energy-efficient components and minimizing operational losses, this load bank aligns with global sustainability trends in industrial power management.
Safety is paramount in high-power testing environments. The AC380V-20KW-RLC Load Bank incorporates multiple layers of protection, including thermal sensors, fuses, and automated shutdown mechanisms. These features ensure secure operation, even during high-stress testing scenarios, safeguarding both operators and equipment.
The GROADA load bank serves a wide spectrum of applications:
Teste do gerador – Verify output, stability, and efficiency
UPS System Validation – Ensure backup power reliability under full load conditions
Inverter Performance Evaluation – Test renewable energy integration and grid stability
EV Charging Infrastructure Testing – Simulate load profiles for EV stations and fleet systems
Its adaptability makes it indispensable for energy providers, industrial facilities, and research laboratories seeking dependable testing solutions.
The global load bank market is expanding rapidly, fueled by increasing investments in renewable energy, power grid modernization, and industrial automation. Reliable power testing is critical for commissioning and maintaining generators, UPS systems, and renewable energy equipment.
Emerging trends shaping the market include:
Digital Monitoring and Automation – Load banks with real-time data analytics enable predictive maintenance and reduce human error
Modular and Portable Designs – Compact, transportable units allow flexible deployment across multiple sites
Energy-Efficient Systems – Reducing operational costs and supporting sustainable practices in alignment with green energy initiatives
By leveraging these advancements, the AC380V-20KW-RLC Load Bank ensures cutting-edge testing capabilities aligned with industry best practices.
Engineered for precision, reliability, and longevity, the GROADA AC380V-20KW-RLC Load Bank is trusted by engineers and energy managers worldwide. Its combination of advanced RLC simulation, real-time digital monitoring, and robust safety mechanisms makes it a top choice for anyone who requires accurate, reliable, and safe power testing solutions.
Invest in performance, dependability, and innovation—experience the GROADA difference in AC load testing.