Banco de carga indutiva resistiva GROADA-AC380V-500KW-RL

★★★★★
Produtos principais:
  • Banco de carga AC: R / RL / RLC / RCD
  • Banco de carga DC: DC5V - 2000V, 0A - 5000A


ModeloAC220V-10KVA-RLAC380O V-30KVA-RLAC380V-60KVA-RLAC380V-100KVA-RLAC380V-300KVA-RLAC380V-500KVA-RLAC380V-1000KVA-RL
Potência nominalRL = 10KVARL = 30KVARL = 60KVARL = 100KVARL = 300KVARL = 500KVARL = 1000KVA
R = 10KW; L = 6KVAR = 30KW; L = 18KVAR = 60KW; L = 36KVAR = 100KW; L = 60KVAR = 300KW; L = 180KVAR = 500KW; L = 300KVAR = 1000KW; L = 600KVA
Corrente de entrada0-45A0-45A0-90A0-150A0-450A0-750A0-1500A
Tamanho (largura * profundidade * altura mm)480*600*277480*600*360500*750*1000600*850*1000700*1000*16501100*1400*17001100*1500*1900
Peso25 quilos40 quilos80 quilos130 quilos250 quilos550 quilos750 quilos
Carga mínima100W100W100W500W1kw5kw10kw
Outra potência mínima de carga pode ser personalizada de acordo com os requisitos
Tensão de entradaAC220 / 230VAC380 / 400V
Outra tensão de entrada pode ser personalizada de acordo com os requisitos
fator de potênciaPF = 0,8/1,0 (outro fator de potência pode ser personalizado de acordo com os requisitos)
Precisão geral3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos)
Modo de controleManual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário)
Interface remotaRS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos)
Função de proteçãoProteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente)
Fonte de alimentação de trabalhoAC220VAC220V / 380VAC380V
Precisão da exibição0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos)
Parâmetros de exibiçãoTensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos)
Frio certa maneiraEntrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos)
Nível de proteçãoIP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos)
cor da aparênciaRAL7035 (outras cores podem ser personalizadas de acordo com os requisitos)
Temperatura de trabalho-10 ℃ ~ 55 ℃
Umidade relativa ≤95%RH
Altitude ≤ 2500 m


Banco de carga resistivo-reativo AC380V 500kW RL

Solução de teste de carga de engenharia de precisão para desempenho de energia confiável


Visão geral

OGROADA AC380V 500kW RL Banco de carga resistente-reativaé um sistema de teste de grau profissional projetado para simular cargas elétricas do mundo real para geradores, unidades UPS, transformadores e outros sistemas de energia AC.
Ao combinarelementos de carga resistivos e reativosnuma única unidade compacta, fornece uma solução completa para testar condições de potência ativa e indutiva em ambientes controlados.

Construído para precisão, segurança e durabilidade, este banco de carga RL oferece desempenho estável durante testes de fábrica, comissionamento e manutenção de rotina de sistemas de energia, garantindo que seu equipamento funcione de forma confiável quando mais importa.


Características principais

1. Carga resistiva e reativa combinada

  • Capacidade total:500 kW em 380 V AC

  • Seções resistivas e indutivas integradas para uma0,8 fator de potênciacapacidade de teste

  • Accurately replicates operational conditions for industrial power systems

  • Smooth load step adjustments with modular switching design

2. Rugged & Reliable Construction

  • Heavy-duty enclosure built for outdoor and industrial environments

  • Vertical hot-air exhaust for efficient heat dissipation

  • High-grade resistor elements ensure low temperature rise and long life

  • Powder-coated housing with corrosion-resistant protection

3. Advanced Safety & Control Systems

  • Equipped with over-temperature, overcurrent, and short-circuit protection

  • Real-time monitoring of current, voltage, frequency, and power factor

  • Available with manual or remote control operation via RS485 or Ethernet interface

  • Emergency stop and automatic cooling fan control for enhanced operator safety

4. Modular Design for Easy Maintenance

  • Front-access layout allows quick service and resistor replacement

  • Detachable sections for transportation and installation flexibility

  • Optional trailer-mounted version for mobile testing applications


Aplicações

The RL Series 500kW load bank is ideal for a wide range of power validation tasks:

  • Generator testing during commissioning and periodic maintenance

  • UPS and inverter testing under full or variable load conditions

  • Switchgear and transformer performance verification

  • Power plant, data center, and microgrid simulations

  • R&D laboratories requiring accurate power factor and dynamic load testing

This model is commonly deployed by EPC contractors, generator manufacturers, testing service providers, and facility maintenance teams worldwide.


Especificações técnicas

ParâmetroEspecificaçãoDescription
Tensão nominalAC 380 V, 3 PhaseCompatible with 50/60 Hz systems
Potência nominal500 kW (Resistive + Reactive)Total combined capacity
Fator de potência0.8 LagSimulates real-world inductive loads
Load Step ResolutionConfigurableFine step loading for flexibility
RefrigeraçãoForced air, vertical exhaustEfficient thermal management
modo controleManual / RemoteLocal panel or RS485/Ethernet
ProteçãoOver-temp, overcurrent, short-circuitFull safety integration
EnclosureOutdoor-rated, IP protection optionalIndustrial-grade design
MobilityFixed or trailer-mountedOptional mobile configuration

Benefits of GROADA Load Banks

  • Accurate Power Simulation: High precision in both resistive and reactive load performance.

  • Operational Safety: Multiple protection layers and thermal safeguards.

  • Ease of Integration: Compatible with SCADA, PLC, and data acquisition systems.

  • Global Engineering Standards: Built to meet CE, ISO, and relevant international test norms.

  • Trusted by Industry Professionals: Proven in continuous operation across data centers, factories, and testing laboratories worldwide.


Insights da indústria

The demand for high-performance load banks continues to grow globally.
According to industry reports (Fortune Business Insights, Spherical Insights, Coherent Market Reports):

  • Oglobal load bank market is projected to reach USD 387 million by 2032, growing at a CAGR of 3.7%.

  • Oresistive load bank segment alone is expected to surpass USD 168 million by 2033, driven by the expansion of data centers, renewable energy systems, and backup power infrastructure.

  • Key growth regions include North America, Europe, and Southeast Asia, where power reliability and testing standards are becoming increasingly stringent.

By integrating advanced testing equipment like GROADA’s RL Series, companies ensure compliance with modern performance and safety benchmarks—reducing downtime and optimizing asset reliability.


Why Choose GROADA

With over a decade of expertise in load testing equipment manufacturing, GROADA has become a trusted partner to power solution providers across the globe.
Our engineering excellence, commitment to quality, and customer-centric support make us a preferred choice for load banks in industrial, utility, and commercial sectors.

Key Strengths:

  • In-house R&D and custom design capability

  • Certified production facilities with strict quality control

  • Global after-sales and technical service network

  • Proven performance in over 40 international markets


Order Information & Support

For configuration details, optional accessories, or customization requests, our technical sales engineers are ready to assist.
We provide detailed datasheets, installation guidance, and calibration certification for each unit.

Standard delivery includes:

  • Load bank unit (resistive + reactive)

  • Cooling and control systems

  • Operation manual & warranty documentation

  • Optional: Remote control kit / Mobile trailer / Spare resistor sets

Warranty: 12 months standard, extended service packages available.