Banco de carga resistiva GROADA-AC380V-150KW-RL
The GROADA-AC380V-150KW-RL resistive load bank is a high-performance testing device designed to simu...
| Modelo | AC220V-10KVA-RL | AC380O V-30KVA-RL | AC380V-60KVA-RL | AC380V-100KVA-RL | AC380V-300KVA-RL | AC380V-500KVA-RL | AC380V-1000KVA-RL |
| Potência nominal | RL = 10KVA | RL = 30KVA | RL = 60KVA | RL = 100KVA | RL = 300KVA | RL = 500KVA | RL = 1000KVA |
| R = 10KW; L = 6KVA | R = 30KW; L = 18KVA | R = 60KW; L = 36KVA | R = 100KW; L = 60KVA | R = 300KW; L = 180KVA | R = 500KW; L = 300KVA | R = 1000KW; L = 600KVA | |
| Corrente de entrada | 0-45A | 0-45A | 0-90A | 0-150A | 0-450A | 0-750A | 0-1500A |
| Tamanho (largura * profundidade * altura mm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| Peso | 25 quilos | 40 quilos | 80 quilos | 130 quilos | 250 quilos | 550 quilos | 750 quilos |
| Carga mínima | 100W | 100W | 100W | 500W | 1kw | 5kw | 10kw |
| Outra potência mínima de carga pode ser personalizada de acordo com os requisitos | |||||||
| Tensão de entrada | AC220 / 230V | AC380 / 400V | |||||
| Outra tensão de entrada pode ser personalizada de acordo com os requisitos | |||||||
| fator de potência | PF = 0,8/1,0 (outro fator de potência pode ser personalizado de acordo com os requisitos) | ||||||
| Precisão geral | 3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos) | ||||||
| Modo de controle | Manual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário) | ||||||
| Interface remota | RS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos) | ||||||
| Função de proteção | Proteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente) | ||||||
| Fonte de alimentação de trabalho | AC220V | AC220V / 380V | AC380V | ||||
| Precisão da exibição | 0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos) | ||||||
| Parâmetros de exibição | Tensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos) | ||||||
| Frio certa maneira | Entrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos) | ||||||
| Nível de proteção | IP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos) | ||||||
| cor da aparência | RAL7035 (outras cores podem ser personalizadas de acordo com os requisitos) | ||||||
| Temperatura de trabalho | -10 ℃ ~ 55 ℃ | ||||||
| Umidade relativa | ≤95%RH | ||||||
| Altitude | ≤ 2500 m | ||||||
OGROADA AC380V 200 kW RL Banco de Carga Resistivo-Reativoé um instrumento de teste de grau profissional projetado paragrupos geradores, sistemas UPS, centros de dados, sistemas de energia marinha e projetos de comissionamento elétrico.
Ele forneceSimulação de carga resistiva e indutiva (tipicamente 0,8 fator de potência atrasado), assegurando umteste abrangente e realistasistemas de energia em condições reais de funcionamento.
Built with industrial-grade components and high-accuracy measurement systems, this unit delivers stable, safe, and repeatable performance for critical power validation.
Suportaresistive (1.0 PF) and resistive + inductive (0.8 PF) operation.
Ideal for simulating real-world electrical characteristics of motors, transformers, and inductive loads.
Enables users to analyze system stability, power factor, and voltage regulation under realistic stress conditions.
Output accuracy up to ±0.5% ensures dependable test results.
Stepwise load control allows gradual and safe power ramping.
Continuous monitoring of voltage, current, power, and PF for precise data collection.
Integrated protection: overload, over-temperature, short-circuitefan failure alarm.
Modular resistor and inductor assemblies simplify inspection and service.
Compact cabinet design suitable for laboratory, plant room, or field testing environments.
High-efficiency air cooling system maintains stable operation under continuous load.
Optional remote monitoring system for data acquisition and real-time control.
Intuitive control interface with touch screen or switch panel.
Supports parallel operation with other load banks for expanded capacity.
| Parâmetro | Especificação |
|---|---|
| Potência nominal | 200 kW |
| Tensão nominal | 380 V AC, 3-phase |
| Fator de potência | 1.0 (resistive) / 0.8 (inductive) |
| Load Step | Customizable (e.g. 5 kW or 10 kW per step) |
| Accuracy | ±0.5% |
| Refrigeração | Forced air cooling |
| Proteção | Overload, over-temperature, short circuit |
| Operating Temperature | –20 °C to +50 °C |
| Enclosure | Indoor/Outdoor, IP54 |
| modo controle | Local / Remote |
| Data Interface | Optional RS485 / Ethernet / MODBUS |
Generator commissioning and performance validation
UPS and inverter testing in data centers and telecom facilities
Periodic maintenance to prevent generator wet stacking
Marine power system simulation and verification
Load sharing and synchronization tests for parallel generators
Factory acceptance tests (FAT) and on-site commissioning
Comprehensive testing for both real and reactive load performance
Improved power factor analysis for optimizing generator performance
Enhanced safety through automated protections and precision control
Global standard compliance (IEC, GB, ISO) ensuring international reliability
Engineered by professionals with years of expertise in load testing and power simulation
According to recent industry reports, the global load bank market is projected to grow from USD 288 million in 2024 to USD 387 million by 2032, driven by the expansion of data centers, renewable energy systems, and industrial backup power solutions.
The demand for resistive-reactive load banks is especially increasing, as more users seek to replicate realistic electrical environments for accurate generator and UPS testing.
This market trend highlights the value of GROADA’s advanced RL load bank solutions, which combine high precision, flexible configuration, and durable performance for modern power infrastructure projects.
Connect the load bank to your generator or UPS system securely.
Perform no-load checks for voltage and frequency stability.
Gradually apply load steps (resistive or inductive) up to the desired level.
Monitor system response — voltage, current, PF, and temperature.
Record test data for analysis and maintenance documentation.
After testing, reduce load to zero and allow cooling fans to run for several minutes.
Inspect components before disconnecting and storage.
Over 10 years of engineering expertise in power testing equipment
Customizable solutions from 10 kW to 5 MW load capacity
Exported to over 50 countries worldwide
Supported by a dedicated technical and after-sales service team
Proven reliability in harsh industrial and offshore environments
GROADA’s mission is to provide trusted and innovative load testing solutions that ensure safety, stability, and efficiency for global power systems.
Q1: What does RL mean in load banks?
RL means Resistivo + indutivo. It combines resistive elements that draw real power (kW) and inductive coils that draw reactive power (kVAR), simulating real-world electrical loads with lagging power factor.
Q2: Why is reactive load testing important?
Reactive testing helps evaluate generator voltage regulation, power factor correction capability, and transient response — critical factors for reliable system operation.
Q3: Can GROADA RL load banks operate outdoors?
Yes, optional weatherproof enclosures (IP54/IP55) make them suitable for outdoor or mobile applications.
Q4: Can multiple load banks be paralleled?
Yes, GROADA RL load banks can be connected in parallel to achieve higher power capacity or multi-system testing.
Q5: How often should load bank testing be done?
Industry best practice recommends at least once a year for standby generators or UPS systems to ensure reliable performance and avoid carbon buildup.
GROADA is a professional manufacturer of industrial load banks and power testing equipment.
We specialize in resistive, inductive, capacitive, and combined load banks from 10 kW to 5 MW, serving industries such as energy, telecom, marine, and manufacturing.
Our products are exported globally and recognized for quality, durability, and engineering precision.
Every GROADA load bank is designed to meet international standards (IEC/GB) and undergoes strict factory testing to ensure optimal performance.