GROADA-AC380V-60KW-R/RCD Fornecedor do banco de carga

★★★★★
Produtos principais:
  • Banco de carga AC: R / RL / RLC / RCD
  • Banco de carga DC: DC5V - 2000V, 0A - 5000A


ModeloAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380O V-30KW-RCDAC380V-50KW-RCDAC380V-60KW-RCDAC380V-100KW-RCDAC380V-200KW-RCD
Potência nominalR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Corrente de entrada0-22A0-45A0-45A0-90A0-45A0-300A0-450A0-600A0-750A
Tamanho (largura * profundidade * altura mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Peso50 quilos80 quilos100 quilos130 quilos200 quilos300 quilos350 quilos450 quilos550 quilos
Tensão de entradaAC220 / 230VAC380 / 400V
Outra tensão de entrada pode ser personalizada de acordo com os requisitos
Carga mínima100W100W100W100W100W1kw1kw1kw1kw
Outra potência mínima de carga pode ser personalizada de acordo com os requisitos
Precisão geral3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos)
fator de potênciaPF = 0,6 ~ 1,0
coeficiente de pico2 a 3
Modo de controleManual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário)
Interface remotaRS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos)
Função de proteçãoProteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente)
Fonte de alimentação de trabalhoAC220VAC220V / AC380V
Precisão da exibição0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos)
Parâmetros de exibiçãoTensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos)
Frio certa maneiraEntrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos)
Nível de proteçãoIP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos)
cor da aparênciaRAL7035 (outras cores podem ser personalizadas de acordo com os requisitos)
Temperatura de trabalho-10 ℃ ~ 55 ℃
Umidade relativa ≤95%RH
Altitude ≤ 2500 m



Banco de carga GROADA AC380V 60KW R / RCD - solução avançada de teste de potência

Visão geral

OBanco de carga GROADA AC380V 60KW R / RCDé um dispositivo de teste de potência de grau profissional projetado para avaliação confiável e precisa de sistemas de energia elétrica. CombinarCargas resistivas, reativas e capacitivas (R/RCD)em uma única unidade, este banco de carga permite que engenheiros e técnicos simulem condições operacionais do mundo real. É ideal parageradores, sistemas UPS e infraestrutura de energia industrialgarantindo desempenho e segurança óptimos em vários cenários de carga.

Projetado para precisão e durabilidade, este banco de carga cumpre rigorosos padrões industriais e fornece umasolução robusta para testes, manutenção e verificação do sistema.


Características principais

1. Simulação de carga abrangente

  • Combina cargas resistivas, reativas e capacitivas para replicar o desempenho de equipamentos eletrônicos modernos e sistemas de energia complexos.

  • Suportareal-world testing for generators, UPS, and critical power systems, ensuring reliability under dynamic load conditions.

2. Capacidade de alta potência

  • Delivers 60KW of total load capacity, suitable for medium to large-scale industrial applications.

  • Can handle a variety of load configurations, providing flexibility for diverse testing requirements.

3. Precision Voltage Compatibility

  • Optimized for AC380V systems, with customizable voltage options for international applications.

  • Ensures accurate simulation for different electrical standards, enhancing testing efficiency.

4. Advanced Control and Monitoring

  • Equipped with a digital control panel for real-time monitoring of voltage, current, power, and load distribution.

  • Allows precise adjustment of load levels, supporting step-load testing, ramp testing, and continuous load testing.

5. Safety-First Design

  • Features overcurrent, overvoltage, and thermal protection mechanisms, safeguarding both the device and the system under test.

  • Incorporates emergency shutdown and fault detection to minimize operational risk.


Aplicações

The GROADA AC380V 60KW R/RCD Load Bank is designed for a wide array of critical applications:

  • Teste do gerador: Validate generator capacity and performance under controlled resistive, reactive, and capacitive loads.

  • UPS System Verification: Evaluate the reliability and efficiency of uninterruptible power supplies in real-world scenarios.

  • Data Center Maintenance: Ensure uninterrupted operation of critical IT infrastructure by simulating peak and variable loads.

  • Industrial and Commercial Power Systems: Test power grids, substations, and industrial machinery for stability and efficiency.


Insights da indústria

Oglobal load bank market is growing steadily due to the increasing demand for reliable and uninterrupted power solutions. According to market research, the sector is expected to expand from $300 million in 2025 to over $387 million by 2032, driven by the proliferation of data centers, renewable energy integration, and industrial automation.

Modern load banks are evolving with trends such as:

  • Modular designs for scalable testing solutions.

  • Digital monitoring for precise and automated load management.

  • Networked load banks for synchronized testing across multiple units.

  • Energy-efficient components reducing operational costs and environmental impact.

The GROADA R/RCD Load Bank incorporates these trends, delivering a cutting-edge testing tool that is both versatile and future-proof.


Why Choose GROADA Load Banks?

  1. Experiência comprovada: Decades of experience in manufacturing industrial-grade load banks.

  2. Customization: Tailored solutions to meet specific load testing requirements.

  3. Reliability: Built for long-term durability and consistent performance in demanding environments.

  4. Comprehensive Support: End-to-end guidance, including installation, calibration, and technical troubleshooting.


Conclusão

For engineers and facility managers seeking a high-precision, reliable, and versatile load testing solution, the Banco de carga GROADA AC380V 60KW R / RCD delivers unmatched performance. By simulating real-world load conditions, it ensures that generators, UPS systems, and industrial power networks operate safely and efficiently, reducing downtime and safeguarding critical infrastructure.

Nosso Produto