| Modelo | AC220V-10KVA-RL | AC380O V-30KVA-RL | AC380V-60KVA-RL | AC380V-100KVA-RL | AC380V-300KVA-RL | AC380V-500KVA-RL | AC380V-1000KVA-RL |
| Potência nominal | RL = 10KVA | RL = 30KVA | RL = 60KVA | RL = 100KVA | RL = 300KVA | RL = 500KVA | RL = 1000KVA |
| R = 10KW; L = 6KVA | R = 30KW; L = 18KVA | R = 60KW; L = 36KVA | R = 100KW; L = 60KVA | R = 300KW; L = 180KVA | R = 500KW; L = 300KVA | R = 1000KW; L = 600KVA | |
| Corrente de entrada | 0-45A | 0-45A | 0-90A | 0-150A | 0-450A | 0-750A | 0-1500A |
| Tamanho (largura * profundidade * altura mm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| Peso | 25 quilos | 40 quilos | 80 quilos | 130 quilos | 250 quilos | 550 quilos | 750 quilos |
| Carga mínima | 100W | 100W | 100W | 500W | 1kw | 5kw | 10kw |
| Outra potência mínima de carga pode ser personalizada de acordo com os requisitos | |||||||
| Tensão de entrada | AC220 / 230V | AC380 / 400V | |||||
| Outra tensão de entrada pode ser personalizada de acordo com os requisitos | |||||||
| fator de potência | PF = 0,8/1,0 (outro fator de potência pode ser personalizado de acordo com os requisitos) | ||||||
| Precisão geral | 3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos) | ||||||
| Modo de controle | Manual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário) | ||||||
| Interface remota | RS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos) | ||||||
| Função de proteção | Proteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente) | ||||||
| Fonte de alimentação de trabalho | AC220V | AC220V / 380V | AC380V | ||||
| Precisão da exibição | 0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos) | ||||||
| Parâmetros de exibição | Tensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos) | ||||||
| Frio certa maneira | Entrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos) | ||||||
| Nível de proteção | IP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos) | ||||||
| cor da aparência | RAL7035 (outras cores podem ser personalizadas de acordo com os requisitos) | ||||||
| Environment Temperature | -10 ℃ ~ 55 ℃ | ||||||
| Umidade relativa | ≤95%RH | ||||||
| Altitude | ≤ 2500 m | ||||||
Precision Testing Solution for Critical Power Systems
OGROADA AC380V-60KW-RL Load Bankis engineeredhigh-precision simulation of electrical loads, providing reliable performance validation for generators, uninterruptible power supplies (UPS), and other critical power infrastructure. With its60 kW capacity, this load bank is ideal for medium to large-scale testing environments, ensuring your power systems operate safely and efficiently under real-world conditions.
This unit seamlessly combinescargas resistivas e indutivas, allowing engineers to replicate complex operational scenarios, such as startup surges, reactive power fluctuations, and transient loads. Its robust construction guarantees consistent performance even under rigorous industrial testing conditions.
Dual Load Simulation:
Combines resistive and inductive loads for comprehensive testing that mirrors real-world electrical conditions.
Capacidade de alta potência:
Rated at 60 kW, suitable for testing medium-to-large generators, UPS units, and industrial power systems.
Compatibilidade de tensão:
Designed380V AC systems, compatible with a wide range of power infrastructure.
Robust & Durable Design:
Constructed with premium-grade materials to withstand demanding environments and frequent use.
Interface amigável ao usuário:
Intuitive controls and digital monitoring facilitate precise operation and real-time performance tracking.
Safety & Compliance:
Incorporates multiple protective mechanisms to ensure operator safety and compliance with international electrical standards.
The GROADA AC380V-60KW-RL load bank is widely used in:
Teste do gerador
Accurately validates generator performance under resistive and reactive loads.
Ensures generator reliability during power outages or peak demand conditions.
UPS System Validation
Tests uninterruptible power supplies under full load and transient conditions.
Ensures backup systems deliver uninterrupted power to critical facilities.
Data Centers & IT Facilities
Maintains operational continuity by testing data center power distribution systems.
Simulates realistic load patterns for energy optimization studies.
Sistemas de Energia Renovável
Evaluates performance of solar, wind, or hybrid systems under variable load conditions.
Supports integration and grid compliance testing.
Oglobal load bank marketis experiencing rapid growth, driven by rising demandreliable, uninterrupted power systemsacross data centers, industrial facilities, and renewable energy applications.
Load banks areessential toolsfor identifying potential failures before they affect critical operations.
They play a key role inregulatory compliance, ensuring systems meet operational and safety standards.
Testing with resistive-inductive load banks supportsgrid stability, particularly in renewable and hybrid power systems.
Market Trend:According to industry reports, load bank utilization is projected to expand significantly, especially in sectors requiring continuous uptime and rigorous system validation.
Enhanced System Reliability: Detects faults early to prevent unexpected downtime.
Extended Equipment Lifespan: Maintains optimal operating conditions, reducing wear and tear.
Operational Cost Savings: Identifies issues before they become expensive failures.
Compliance & Safety Assurance: Meets international standards and ensures operator safety.
Comprehensive Load Analysis: Simulates realistic electrical scenarios for better system design and maintenance planning.
OGROADA AC380V-60KW-RL Resistive-Inductive Load Bankis aprofessional-grade solutionfor testing and validating critical power systems. Itsrobust design, dual-load capability, and user-friendly operationmake it an indispensable tool for engineers, facility managers, and testing professionals who demandprecision, reliability, and compliance.
Invest in the GROADA AC380V-60KW-RL to ensure your power systems are fully prepared for real-world conditions, safeguarding both performance and safety.