Banco de carga do inversor GROADA-AC380V-50KW-R/RCD
The GROADA AC380V-50KW-R/RCD inverter test load bank is a high-performance testing device specifical...
| Modelo | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V - 30KW-RCD | AC380V - 50KW-RCD | AC380V - 60KW-RCD | AC380V - 100KW-RCD | AC380V - 200KW-RCD |
| Potência nominal | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Corrente de entrada | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| Tamanho (largura * profundidade * altura mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Peso | 50 quilos | 80 quilos | 100 quilos | 130 quilos | 200 quilos | 300 quilos | 350 quilos | 450 quilos | 550 quilos |
| Tensão de entrada | AC220 / 230V | AC380 / 400V | |||||||
| Outra tensão de entrada pode ser personalizada de acordo com os requisitos | |||||||||
| Carga mínima | 100W | 100W | 100W | 100W | 100W | 1kw | 1kw | 1kw | 1kw |
| Outra potência mínima de carga pode ser personalizada de acordo com os requisitos | |||||||||
| Precisão geral | 3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos) | ||||||||
| fator de potência | PF = 0,6 ~ 1,0 | ||||||||
| coeficiente de pico | 2 a 3 | ||||||||
| Modo de controle | Manual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário) | ||||||||
| Interface remota | RS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos) | ||||||||
| Função de proteção | Proteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente) | ||||||||
| Fonte de alimentação de trabalho | AC220V | AC220V / AC380V | |||||||
| Precisão da exibição | 0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos) | ||||||||
| Parâmetros de exibição | Tensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos) | ||||||||
| Frio certa maneira | Entrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos) | ||||||||
| Nível de proteção | IP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos) | ||||||||
| cor da aparência | RAL7035 (outras cores podem ser personalizadas de acordo com os requisitos) | ||||||||
| Temperatura de trabalho | -10 ℃ ~ 55 ℃ | ||||||||
| Umidade relativa | ≤95%RH | ||||||||
| Altitude | ≤ 2500 m | ||||||||
O teste do inversor sob cargas realistas e controláveis é essencial para verificar o desempenho, a confiabilidade, a durabilidade e a segurança. Um banco de carga devidamente projetado permite:
Teste de tensão reprodutível sob carga completa, carga parcial e condições transitórias
Controle sobre cargas resistivas, indutivas ou combinadas simulando interações de motor ou rede do mundo real
Validação de circuitos de proteção (sobrecorrente, sobretensão, desligamento térmico)
Verificação da estabilidade térmica a longo prazo, envelhecimento e degradação dos componentes
Sem tal banco de carga, os testes do inversor podem confiar apenas nas condições de campo ou no acoplamento do motor, o que pode obscurecer a análise da causa raiz e reduzir a repetibilidade.
De fato, os laboratórios de teste padrão da indústria usam cargas passivas (resistivas / indutivas) e ativas (cargas eletrônicas regenerativas ou emuladores de motores) para voltar totalmente os inversores.
This product page presents a high-precision inverter load bank, specifically designed for AC 380 V systems, capable of handling up to 30 kW rated load. Below is an enhanced, SEO-optimized description:
Nominal Voltage: 380 V AC
Potência nominal: 30 kW continuous
Tipo de carga: RCD (Resistive + Capacitive + Inductive combinations)
Load Control Modes: stepwise or continuous adjustment, enabling partial load (e.g. 10 %, 25 %, 50 %, 75 %, 100 %)
Cooling & Thermal Management: forced-air or liquid cooling to maintain stable temperatures under full load
Protection Mechanisms: overcurrent, overvoltage, short-circuit, phase loss, overheating
Load Bank Construction: high-stability precision resistors/inductors, modular load elements
Measurement & Monitoring: integrated current, voltage, power, and temperature sensors; optional logging or remote communication
These features empower R&D labs, quality assurance teams, and inverter manufacturers to test inverters precisely under controlled, repeatable load conditions.
During the design and prototyping phases, engineers can use this load bank to:
Verify full-load performance, thermal limits, and efficiency curves
Stress-test inverter switching components (IGBTs, MOSFETs)
Simulate part-load, transient, and overload scenarios
Validate cooling systems under real thermal load
In mass manufacturing, this load bank can be integrated into automatic test sequences:
Run “burn-in” or "soak" tests to detect early-life failures
Ensure each unit meets declared performance before shipping
Automate pass/fail criteria based on voltage, current, power, and temperature thresholds
After deployment (in solar farms, microgrids, industrial power systems), periodic or after-maintenance tests help:
Confirm the inverter still performs within specification
Detect degradation (e.g. diminished cooling, capacitor aging)
Validate protection circuits and safety margins
Testing inverters with a load bank is considered a best practice in many critical power installations to prevent unexpected failure.
Below is a recommended step-by-step workflow and key considerations:
| Phase | Actions | Purpose / Checks |
|---|---|---|
| Setup & Safety Check | Inspect wiring, ensure insulation and grounding, perform open-circuit checks | Prevent shorts or unsafe conditions |
| No-load / Idle Measurement | Run inverter unloaded, measure baseline current, voltage, harmonic distortion | Confirm zero-load behavior and idle losses |
| Step Load Ramp | Apply incremental loads (e.g. 10 %, 25 %, 50 %, 75 %, 100 %) | Assess linearity, thermal drift, current stability |
| Full-load Endurance / Soak Test | Run at full load for extended duration (hours to days) | Monitor temperature, drift, cooling effectiveness |
| Transient Tests | Introduce load steps, sudden load removal (load rejection), or overload transients | Measure inverter’s dynamic response, grid-interaction behavior |
| Protection Verification | Deliberately exceed ratings to trigger overcurrent, overvoltage, or thermal protections | Validate that safety circuits engage reliably |
Always wear proper PPE (insulating gloves, goggles) when handling high-voltage systems.
Ensure the load bank and inverter are in good ventilation and clean environment (no dust accumulation).
Use power meters or precision instrumentation to measure input/output, so your efficiency calculations are accurate.
Avoid exceeding design limits of the inverter or load bank – inconsistent or overloaded operation can damage components.
Record all data logs systematically for traceability and future analysis.
To support EEAT and improve trust, you may wish to include:
Testing data and charts (efficiency curve, thermal profiles)
Third-party lab certifications (e.g. IEC, UL, CE compliance)
Case studies or whitepapers where this or similar load banks have been used (e.g. in inverter manufacturers’ labs)
Technical team credentials (engineers, years in power electronics, publications)
Guarantees and warranty terms, e.g. accuracy drift, calibration support
Our AC 380V 30 kW RCD Inverter Load Bank is engineered by a team with over 10 years of experience in power electronics test systems. Designed for R&D, QA, and maintenance verification, it meets international accuracy and safety standards. Each unit is factory-calibrated and accompanied by a calibration certificate. We also offer custom configurations (higher power, alternate voltages, communication interfaces) to support evolving test requirements.