Banco de carga de teste do inversor

Banco de carga do inversor GROADA-AC380V-30KW-RCD

★★★★★
Produtos principais:
  • Banco de carga AC: R / RL / RLC / RCD
  • Banco de carga DC: DC5V - 2000V, 0A - 5000A


ModeloAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V - 30KW-RCDAC380V - 50KW-RCDAC380V - 60KW-RCDAC380V - 100KW-RCDAC380V - 200KW-RCD
Potência nominalR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Corrente de entrada0-22A0-45A0-45A0-90A0-45A0-300A0-450A0-600A0-750A
Tamanho (largura * profundidade * altura mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Peso50 quilos80 quilos100 quilos130 quilos200 quilos300 quilos350 quilos450 quilos550 quilos
Tensão de entradaAC220 / 230VAC380 / 400V
Outra tensão de entrada pode ser personalizada de acordo com os requisitos
Carga mínima100W100W100W100W100W1kw1kw1kw1kw
Outra potência mínima de carga pode ser personalizada de acordo com os requisitos
Precisão geral3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos)
fator de potênciaPF = 0,6 ~ 1,0
coeficiente de pico2 a 3
Modo de controleManual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário)
Interface remotaRS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos)
Função de proteçãoProteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente)
Fonte de alimentação de trabalhoAC220VAC220V / AC380V
Precisão da exibição0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos)
Parâmetros de exibiçãoTensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos)
Frio certa maneiraEntrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos)
Nível de proteçãoIP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos)
cor da aparênciaRAL7035 (outras cores podem ser personalizadas de acordo com os requisitos)
Temperatura de trabalho-10 ℃ ~ 55 ℃
Umidade relativa ≤95%RH
Altitude ≤ 2500 m



AC-380V 30 kW RCD Inverter Load Bank Solução de teste de alta precisão

Por que escolher um banco de carga de inversor dedicado?

O teste do inversor sob cargas realistas e controláveis é essencial para verificar o desempenho, a confiabilidade, a durabilidade e a segurança. Um banco de carga devidamente projetado permite:

  • Teste de tensão reprodutível sob carga completa, carga parcial e condições transitórias

  • Controle sobre cargas resistivas, indutivas ou combinadas simulando interações de motor ou rede do mundo real

  • Validação de circuitos de proteção (sobrecorrente, sobretensão, desligamento térmico)

  • Verificação da estabilidade térmica a longo prazo, envelhecimento e degradação dos componentes

Sem tal banco de carga, os testes do inversor podem confiar apenas nas condições de campo ou no acoplamento do motor, o que pode obscurecer a análise da causa raiz e reduzir a repetibilidade.

De fato, os laboratórios de teste padrão da indústria usam cargas passivas (resistivas / indutivas) e ativas (cargas eletrônicas regenerativas ou emuladores de motores) para voltar totalmente os inversores.  


Product Overview: AC 380V 30 kW RCD Load Bank

This product page presents a high-precision inverter load bank, specifically designed for AC 380 V systems, capable of handling up to 30 kW rated load. Below is an enhanced, SEO-optimized description:

Key Specifications & Features

  • Nominal Voltage: 380 V AC

  • Potência nominal: 30 kW continuous

  • Tipo de carga: RCD (Resistive + Capacitive + Inductive combinations)

  • Load Control Modes: stepwise or continuous adjustment, enabling partial load (e.g. 10 %, 25 %, 50 %, 75 %, 100 %)

  • Cooling & Thermal Management: forced-air or liquid cooling to maintain stable temperatures under full load

  • Protection Mechanisms: overcurrent, overvoltage, short-circuit, phase loss, overheating

  • Load Bank Construction: high-stability precision resistors/inductors, modular load elements

  • Measurement & Monitoring: integrated current, voltage, power, and temperature sensors; optional logging or remote communication

These features empower R&D labs, quality assurance teams, and inverter manufacturers to test inverters precisely under controlled, repeatable load conditions.


Applications & Use Cases

1. Inverter Development & Validation

During the design and prototyping phases, engineers can use this load bank to:

  • Verify full-load performance, thermal limits, and efficiency curves

  • Stress-test inverter switching components (IGBTs, MOSFETs)

  • Simulate part-load, transient, and overload scenarios

  • Validate cooling systems under real thermal load

2. Production & Quality Assurance (QA)

In mass manufacturing, this load bank can be integrated into automatic test sequences:

  • Run “burn-in” or "soak" tests to detect early-life failures 

  • Ensure each unit meets declared performance before shipping

  • Automate pass/fail criteria based on voltage, current, power, and temperature thresholds

3. Maintenance & Field Verification

After deployment (in solar farms, microgrids, industrial power systems), periodic or after-maintenance tests help:

  • Confirm the inverter still performs within specification

  • Detect degradation (e.g. diminished cooling, capacitor aging)

  • Validate protection circuits and safety margins

Testing inverters with a load bank is considered a best practice in many critical power installations to prevent unexpected failure. 


Testing Methodology: How to Use the Load Bank Correctly

Below is a recommended step-by-step workflow and key considerations:

PhaseActionsPurpose / Checks
Setup & Safety CheckInspect wiring, ensure insulation and grounding, perform open-circuit checksPrevent shorts or unsafe conditions
No-load / Idle MeasurementRun inverter unloaded, measure baseline current, voltage, harmonic distortionConfirm zero-load behavior and idle losses
Step Load RampApply incremental loads (e.g. 10 %, 25 %, 50 %, 75 %, 100 %)Assess linearity, thermal drift, current stability
Full-load Endurance / Soak TestRun at full load for extended duration (hours to days)Monitor temperature, drift, cooling effectiveness
Transient TestsIntroduce load steps, sudden load removal (load rejection), or overload transientsMeasure inverter’s dynamic response, grid-interaction behavior 
Protection VerificationDeliberately exceed ratings to trigger overcurrent, overvoltage, or thermal protectionsValidate that safety circuits engage reliably

Important Best Practices & Precautions

  • Always wear proper PPE (insulating gloves, goggles) when handling high-voltage systems.

  • Ensure the load bank and inverter are in good ventilation and clean environment (no dust accumulation).

  • Use power meters or precision instrumentation to measure input/output, so your efficiency calculations are accurate. 

  • Avoid exceeding design limits of the inverter or load bank – inconsistent or overloaded operation can damage components.

  • Record all data logs systematically for traceability and future analysis.


Differentiation & Advantages (Establishing Authority & Trust)

To support EEAT and improve trust, you may wish to include:

  • Testing data and charts (efficiency curve, thermal profiles)

  • Third-party lab certifications (e.g. IEC, UL, CE compliance)

  • Case studies or whitepapers where this or similar load banks have been used (e.g. in inverter manufacturers’ labs)

  • Technical team credentials (engineers, years in power electronics, publications)

  • Guarantees and warranty terms, e.g. accuracy drift, calibration support

Our AC 380V 30 kW RCD Inverter Load Bank is engineered by a team with over 10 years of experience in power electronics test systems. Designed for R&D, QA, and maintenance verification, it meets international accuracy and safety standards. Each unit is factory-calibrated and accompanied by a calibration certificate. We also offer custom configurations (higher power, alternate voltages, communication interfaces) to support evolving test requirements.