GROADA-AC220V-15KW-RLC Banco de carga fabricante
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| Modelo | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Potência nominal | RLC = 10KVA | RLC = 30KVA | RLC = 60KVA | RLC = 100KVA | RLC = 200KVA | RLC = 300KVA |
| R = 10KW; L = 10KVA C = 10KVA | R = 30KW; L = 30KVA; C = 30KVA | R = 60KW; L = 60KVA; C = 60KVA | R = 100KW; L = 100KVA; C = 100KVA | R = 200KW; L = 200KVA; C = 200KVA | R = 300KW; L = 300KVA; C = 300KVA | |
| Outro poder pode ser personalizado de acordo com os requisitos | ||||||
| Tamanho (largura * profundidade * altura mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Peso | 120 quilos | 380 quilos | 580 quilos | 880 quilos | 1500 quilos | 2500 quilos |
| Tensão de entrada | AC220 / 230V | AC380 / 400V | ||||
| Outra tensão de entrada pode ser personalizada de acordo com os requisitos | ||||||
| Corrente de entrada | 0-45A | 0-45A | 0-90A | 0-150A | 0-300A | 0-450A |
| Carga mínima | R = 100W; L=100VA; C = 100VA | R = 100W; L=100VA; C = 100VA | R = 100W; L=100VA; C = 100VA | R = 100W; L=100VA; C = 100VA | R = 1KW; L = 1KVA; C = 1KVA | R = 1KW; L = 1KVA; C = 1KVA |
| Outra potência mínima de carga pode ser personalizada de acordo com os requisitos | ||||||
| fator de potência | PF = 0,1 ~ 1,0 (outro fator de potência pode ser personalizado de acordo com os requisitos) | |||||
| Precisão geral | 3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos) | |||||
| Modo de controle | Manual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário) | |||||
| Interface remota | RS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos) | |||||
| Função de proteção | Proteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente) | |||||
| Fonte de alimentação de trabalho | AC220V | AC220V / 380V | AC380V | |||
| Precisão da exibição | 0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos) | |||||
| Parâmetros de exibição | Tensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos) | |||||
| Frio certa maneira | Entrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos) | |||||
| Nível de proteção | IP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos) | |||||
| cor da aparência | RAL7035 (outras cores podem ser personalizadas de acordo com os requisitos) | |||||
| Temperatura de trabalho | -10 ℃ ~ 55 ℃ | |||||
| Umidade relativa | ≤95%RH | |||||
| Altitude | ≤ 2500 m | |||||
Ensure Optimal Performance, Reliability, and Safety Across Your Power Infrastructure
OGROADA AC380V 20KW RLC Load Bank is a high-performance testing solution designed for validating the reliability and efficiency of power generation and distribution systems. Combining cargas resistivas, indutivas e capacitivas, it simulates real-world electrical conditions, enabling engineers and technicians to identify potential issues before they become critical failures.
Whether for generators, UPS systems, data centers, or renewable energy integration, this load bank delivers precise, repeatable, and safe testing results, ensuring your critical power systems operate at peak efficiency under any scenario.
Incorporates resistive (R), inductive (L), and capacitive (C) loads to accurately replicate the behavior of real electrical systems.
Allows precise simulation of different load types, including reactive and non-linear loads.
Supports a wide power factor range from 0.1 to 1.0, enabling testing under various operating conditions.
Critical for validating system performance in applications where reactive loads are present.
Modular architecture ensures easy scalability and allows customization based on specific testing needs.
Compact, robust, and transportable design ensures versatility in both field and laboratory environments.
Intuitive control panel provides real-time monitoring of voltage, current, power, and power factor.
Optional remote control functionality allows for safe operation from a distance.
Equipado comoverload protection, short-circuit protection, and over-temperature alarms.
Ensures operator safety and prevents damage to both the load bank and tested equipment.
Simulates realistic load conditions to verify generator performance, efficiency, and reliability.
Ensures compliance with operational standards and minimizes the risk of failure during peak demand.
Tests UPS functionality under varied resistive, inductive, and capacitive loads.
Ensures backup power systems maintain reliability during outages.
Evaluates solar, wind, or hybrid power systems under dynamic load conditions.
Helps optimize inverter and storage system performance for consistent energy delivery.
Confirms that backup power systems and generators can handle high-demand, critical loads.
Prevents downtime and ensures business continuity.
The GROADA AC380V 20KW RLC Load Bank is designed to meet international safety and performance standards, ensuring both reliability and operational compliance:
IEEE 1547 – Standard for testing distributed energy resources.
NFPA 110 – Requirements for emergency and standby power systems.
ISO 8528-10 – Load acceptance testing standards for generating sets.
Compliance with these standards guarantees that the load bank can be safely and effectively integrated into professional power testing environments worldwide.
Reliability Assurance – Early detection of system weaknesses prevents critical failures.
Performance Optimization – Testing under real-world load conditions ensures generators, UPS units, and other systems perform efficiently.
Cost Efficiency – Proactive testing reduces costly emergency repairs and downtime.
Operational Confidence – Verifies that backup power systems are ready for emergency operation.
| Especificação | Detalhes |
|---|---|
| Potência nominal | 20KW |
| Tensão | AC380V |
| Frequência | 50/60Hz |
| Fator de potência | 0.1 – 1.0 |
| modo controle | Local panel and optional remote |
| Características de segurança | Overload, short circuit, over-temp alarms |
GROADA RLC Load Banks are trusted globally by power generation companies, data centers, and critical infrastructure operators. Our solutions are engineered for accuracy, durability, and ease of use, providing peace of mind for engineers and facility managers alike.
Email: groadacn@163.com
Phone: +86-755-23339096