Banco de carga resistiva GROADA-AC380V-150KW-RL
The GROADA-AC380V-150KW-RL resistive load bank is a high-performance testing device designed to simu...
| Modelo | AC220V-10KVA-RL | AC380O V-30KVA-RL | AC380V-60KVA-RL | AC380V-100KVA-RL | AC380V-300KVA-RL | AC380V-500KVA-RL | AC380V-1000KVA-RL |
| Potência nominal | RL = 10KVA | RL = 30KVA | RL = 60KVA | RL = 100KVA | RL = 300KVA | RL = 500KVA | RL = 1000KVA |
| R = 10KW; L = 6KVA | R = 30KW; L = 18KVA | R = 60KW; L = 36KVA | R = 100KW; L = 60KVA | R = 300KW; L = 180KVA | R = 500KW; L = 300KVA | R = 1000KW; L = 600KVA | |
| Corrente de entrada | 0-45A | 0-45A | 0-90A | 0-150A | 0-450A | 0-750A | 0-1500A |
| Tamanho (largura * profundidade * altura mm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| Peso | 25 quilos | 40 quilos | 80 quilos | 130 quilos | 250 quilos | 550 quilos | 750 quilos |
| Carga mínima | 100W | 100W | 100W | 500W | 1kw | 5kw | 10kw |
| Outra potência mínima de carga pode ser personalizada de acordo com os requisitos | |||||||
| Tensão de entrada | AC220 / 230V | AC380 / 400V | |||||
| Outra tensão de entrada pode ser personalizada de acordo com os requisitos | |||||||
| fator de potência | PF = 0,8/1,0 (outro fator de potência pode ser personalizado de acordo com os requisitos) | ||||||
| Precisão geral | 3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos) | ||||||
| Modo de controle | Manual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário) | ||||||
| Interface remota | RS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos) | ||||||
| Função de proteção | Proteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente) | ||||||
| Fonte de alimentação de trabalho | AC220V | AC220V / 380V | AC380V | ||||
| Precisão da exibição | 0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos) | ||||||
| Parâmetros de exibição | Tensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos) | ||||||
| Frio certa maneira | Entrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos) | ||||||
| Nível de proteção | IP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos) | ||||||
| cor da aparência | RAL7035 (outras cores podem ser personalizadas de acordo com os requisitos) | ||||||
| Temperatura de trabalho | -10 ℃ ~ 55 ℃ | ||||||
| Umidade relativa | ≤95%RH | ||||||
| Altitude | ≤ 2500 m | ||||||
Ao comissionar, manter ou validar sistemas de energia de missão crítica, você precisa de mais do que "apenas carregar". Você precisa de precisão, flexibilidade e confiança em condições do mundo real. OGROADA AC600V 180 kVA RL Banco de carga resistiva-indutivafornece uma plataforma robusta e comprovada em campo para testes de todo o espectro de geradores / UPS / sistemas de energia, combinando elementos de carga resistivos e indutivos em uma solução compacta e modular.
Simulando cargas reais (resistivas) e reativas (indutivas) (geralmente com um fator de potência alvo como 0,8), este banco de carga RL ajuda a validar a estabilidade da tensão do sistema, a resposta à corrente, o comportamento transitório e a capacidade completa da placa do gerador - tudo antes da implantação real.
Suporta carga resistiva (para potência real) e carga indutiva (para potência reativa atrasada), permitindo testes de tensão mais realistas do sistema de energia.
Pode fornecer testes em0,8 fator de potência by combining resistive and inductive sections, a commonly accepted standard for generator acceptance tests.
Offers flexible operation: resistive-only mode, inductive-only mode, or combined RL mode as required.
Rated for 600 V AC input, three-phase (other voltages available upon request).
Rated capacity: 180 kVA, typically meaning ~144 kW resistive + ~108 kVAR inductive (depending on configuration).
Load steps as fine as 100 W / 100 VAR (or higher granularity options), allowing precise load modulation.
Accuracy: ±3% (customizable to tighter tolerances on request).
Display & monitoring: shows voltage, current, real and reactive power, frequency, power factor, etc.
Control options: Local manual (breakers, buttons, touch panel) or remote interface (RS232 / RS485 / USB / RJ45 / CAN / GPIB) — enabling integration into test rigs or SCADA systems.
Emergency-stop (E-stop) protection to instantly remove load under critical conditions.
Over-temperature, fan failure, over-current, short circuit, and insufficient air flow protection.
Grounding protection and isolation to ensure safe operation.
IP rating (e.g. IP20 standard) (optional upgrades for harsher environments).
Thermal management: side air intake / top exhaust, modular airflow design to reduce hotspots.
Designed to operate over –10 °C to +55 °C ambient, up to ~2,500 m altitude.
Enclosure constructed from heavy-gauge steel, powder-coated for corrosion resistance.
Modular sections for resistive and inductive elements; scalable and maintainable.
Forklift channels or lifting eyes provided for ease of installation.
Compact footprint given the power class, enabling rooftop, pad, or indoor installation.
Customization: different frame sizes, color (RAL family), door arrangements, cooling layouts.
Generator Commissioning & Load Acceptance Tests
Validate that your generator set can sustain rated kVA, voltage regulation, transient response, and reactive load behavior before it enters service.
UPS / Power System Integration Testing
Emulate real-world loads (including reactive loads such as motors and inductive circuits) to ensure the UPS and switchgear respond correctly under full stress.
Parallel Generator Synchronization & Load Sharing
Use the RL load bank to balance and test load sharing across multiple gensets, ensuring stability during parallel operations.
Routine Preventive Maintenance / Health Checks
Regular load banking helps avoid “wet stacking” (in diesel gensets running light) and can burn off carbon buildup, improving fuel efficiency and engine life.
Many industry guidelines recommend at least annual full-load testing under rated power factor.
Design Validation & R&D in Power Systems
For OEMs, labs, or integrators, the RL load bank is essential when developing alternators, power converters, controllers, or new power architectures (e.g. microgrids).
Data Centers, Telecom, Critical Infrastructure
In critical facilities where downtime is not tolerated, you must ensure every component performs under combined resistive and reactive stress.
Expertise & Authority: GROADA has decades of experience in power testing equipment, certified by relevant quality and safety standards.
Certifications & Quality Control: Each RL unit undergoes factory calibration, burn-in, and full functional testing before delivery.
Transparent Specifications: All electrical, thermal, mechanical parameters are documented and open to customer review or 3rd-party validation.
Post-Sales Support & Warranty: GROADA offers technical support, spare parts, and extended warranties — helping clients confidently deploy and maintain systems.
Integrated dual-mode design eliminates the need to buy separate resistive and inductive banks — saving cost, footprint, and complexity.
Fine load step resolution and remote control capability give customers flexibility for nuanced stress tests.
Strong reliability and proven design reduce lifetime maintenance and downtime risk.
Customs and configurations possible: if your project needs a custom voltage, power factor, enclosure, or interface, GROADA can accommodate.