Banco de carga do inversor GROADA-AC380V-50KW-R/RCD
The GROADA AC380V-50KW-R/RCD inverter test load bank is a high-performance testing device specifical...
| Modelo | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380O V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| Potência nominal | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Corrente de entrada | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| Tamanho (largura * profundidade * altura mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Peso | 50 quilos | 80 quilos | 100 quilos | 130 quilos | 200 quilos | 300 quilos | 350 quilos | 450 quilos | 550 quilos |
| Tensão de entrada | AC220 / 230V | AC380 / 400V | |||||||
| Outra tensão de entrada pode ser personalizada de acordo com os requisitos | |||||||||
| Carga mínima | 100W | 100W | 100W | 100W | 100W | 1kw | 1kw | 1kw | 1kw |
| Outra potência mínima de carga pode ser personalizada de acordo com os requisitos | |||||||||
| Precisão geral | 3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos) | ||||||||
| fator de potência | PF = 0,6 ~ 1,0 | ||||||||
| coeficiente de pico | 2 a 3 | ||||||||
| Modo de controle | Manual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário) | ||||||||
| Interface remota | RS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos) | ||||||||
| Função de proteção | Proteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente) | ||||||||
| Fonte de alimentação de trabalho | AC220V | AC220V / AC380V | |||||||
| Precisão da exibição | 0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos) | ||||||||
| Parâmetros de exibição | Tensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos) | ||||||||
| Frio certa maneira | Entrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos) | ||||||||
| Nível de proteção | IP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos) | ||||||||
| cor da aparência | RAL7035 (outras cores podem ser personalizadas de acordo com os requisitos) | ||||||||
| Temperatura de trabalho | -10 ℃ ~ 55 ℃ | ||||||||
| Umidade relativa | ≤95%RH | ||||||||
| Altitude | ≤ 2500 m | ||||||||
The GROADA AC600V 25 kW Inverter Load Bank is a purpose-built testing solution for inverter manufacturers, laboratories, and power electronics engineers who require accurate, repeatable, and safe performance validation. Designed for modern renewable energy and energy storage applications, it provides a controlled environment to simulate real-world operating conditions and ensure that inverters meet stringent reliability and efficiency standards.
As solar, battery, and microgrid systems continue to expand, inverter reliability has become more critical than ever. A professional load bank is essential to verify design claims, reduce risk of failure, and build customer trust.
An inverter load bank is a precision device that applies an electrical load to an inverter under test in a safe, controlled manner. Unlike passive field testing, which exposes equipment to unpredictable conditions, a load bank delivers stable and adjustable loads, enabling engineers to:
Measure conversion efficiency across different load levels
Analyze inverter thermal behavior under continuous operation
Validate overcurrent, overvoltage, and protection features
Test inverter performance with both resistive and reactive loads
Confirm grid-compliance functions such as anti-islanding and synchronization
This makes the GROADA AC600V 25 kW Load Bank an indispensable tool for inverter R&D, production quality assurance, and third-party certification.
600 V DC input and 25 kW power capacity — suitable for medium-scale PV and ESS inverters
Programmable load profiles — supports stepped, gradual, or dynamic load changes
Resistive, reactive, and inductive test modes — replicates real-world load conditions
Energy regenerative design — reduces wasted energy by feeding it back to the grid
High measurement accuracy — captures voltage, current, frequency, THD, and power factor with precision
Comprehensive protection — includes overcurrent, overvoltage, and thermal safeguards
Modular scalability — units can be combined for higher test power requirements
Industrial-grade reliability — robust cooling, durable construction, and long service life
By gradually stepping through load levels (10%, 20%, 50%, 100%), engineers can generate inverter efficiency curves and quantify power losses. This is essential for meeting regulatory requirements and optimizing design.
Sustained full-power operation simulates demanding field conditions. Engineers can verify cooling system performance, detect hot spots, and assess component aging over time.
Real electrical networks rarely operate with pure resistive loads. The ability to test with inductive or capacitive elements ensures accurate validation of power factor correction, stability, and reactive power handling.
Step loads, sudden drops, or rapid fluctuations test the robustness of inverter control loops. Load banks can uncover hidden weaknesses in firmware or protection systems that would otherwise appear only in the field.
Grid codes worldwide require inverters to handle abnormal conditions such as voltage dips, frequency shifts, or anti-islanding detection. A load bank allows safe simulation of these events to prove compliance with IEC, IEEE, and UL standards.
Solar Photovoltaic Inverters — verifying efficiency, MPP tracking, and safety under variable sunlight conditions
Energy Storage Systems (ESS) — testing bidirectional inverters and charge/discharge cycles
Microgrids and Hybrid Power Systems — ensuring reliable power sharing and seamless transitions
R&D Laboratories — supporting prototype evaluation and academic research in power electronics
Manufacturing QA — providing repeatable end-of-line testing before product shipment
Trusted Accuracy – Designed with precision instrumentation for reliable test results.
Energy Savings – Regenerative design minimizes waste and reduces operational costs.
Operator Safety – Integrated protections and emergency shutoffs ensure safe operation.
Flexibility – Adaptable to multiple inverter types, from residential PV to industrial storage.
Future-Proof – Modular capacity supports expansion as test demands grow.
The GROADA 25 kW Inverter Load Bank is engineered to support compliance testing with major global standards, including:
IEC 62116 – Test procedure of islanding prevention measures for grid-connected PV inverters
IEC 61000 – Electromagnetic compatibility requirements
IEEE 1547 – Standard for interconnection and interoperability of distributed resources
UL 1741 – Inverters, converters, and controllers for use in distributed energy resources
Meeting these standards is essential for manufacturers aiming to enter international markets with certified products.
GROADA specializes in advanced load bank solutions for the renewable energy and power electronics industries. Our engineering team brings years of field experience and technical expertise, ensuring products that combine innovation, durability, and cost efficiency.
By partnering with GROADA, customers gain more than equipment — they gain a trusted testing partner committed to quality, reliability, and global support.
The GROADA AC600V 25 kW Inverter Load Bank empowers inverter developers, manufacturers, and testing laboratories with a reliable, precise, and efficient tool for performance validation. From efficiency mapping to grid-compliance testing, it delivers the insights needed to design robust, safe, and market-ready inverters.
Investing in a professional load bank is not just about compliance — it is about ensuring long-term reliability, customer satisfaction, and competitive advantage in the fast-growing renewable energy sector.