GROADA-AC346V-50KVA-RL Caixa de carga indutiva resistiva

★★★★★
Produtos principais:
  • Banco de carga AC: R / RL / RLC / RCD
  • Banco de carga DC: DC5V - 2000V, 0A - 5000A


ModeloAC220V-10KVA-RLAC380O V-30KVA-RLAC380V-60KVA-RLAC380V-100KVA-RLAC380V-300KVA-RLAC380V-500KVA-RLAC380V-1000KVA-RL
Potência nominalRL = 10KVARL = 30KVARL = 60KVARL = 100KVARL = 300KVARL = 500KVARL = 1000KVA
R = 10KW; L = 6KVAR = 30KW; L = 18KVAR = 60KW; L = 36KVAR = 100KW; L = 60KVAR = 300KW; L = 180KVAR = 500KW; L = 300KVAR = 1000KW; L = 600KVA
Corrente de entrada0-45A0-45A0-90A0-150A0-450A0-750A0-1500A
Tamanho (largura * profundidade * altura mm)480*600*277480*600*360500*750*1000600*850*1000700*1000*16501100*1400*17001100*1500*1900
Peso25 quilos40 quilos80 quilos130 quilos250 quilos550 quilos750 quilos
Carga mínima100W100W100W500W1kw5kw10kw
Outra potência mínima de carga pode ser personalizada de acordo com os requisitos
Tensão de entradaAC220 / 230VAC380 / 400V
Outra tensão de entrada pode ser personalizada de acordo com os requisitos
fator de potênciaPF = 0,8/1,0 (outro fator de potência pode ser personalizado de acordo com os requisitos)
Precisão geral3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos)
Modo de controleManual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário)
Interface remotaRS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos)
Função de proteçãoProteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente)
Fonte de alimentação de trabalhoAC220VAC220V / 380VAC380V
Precisão da exibição0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos)
Parâmetros de exibiçãoTensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos)
Frio certa maneiraEntrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos)
Nível de proteçãoIP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos)
cor da aparênciaRAL7035 (outras cores podem ser personalizadas de acordo com os requisitos)
Temperatura de trabalho-10 ℃ ~ 55 ℃
Umidade relativa ≤95%RH
Altitude ≤ 2500 m



AC 346V 50 kVA RL Resistivo/Banco de carga indutiva

Precisão, confiabilidade e testes de potência do mundo real da GROADA


Visão geral

OGROADA AC 346V 50 kVA RL Banco de cargaé um sistema de teste de alta precisão projetado para simular amboscargas resistivas e indutivaspara geradores, sistemas UPS, turbinas e redes de energia elétrica.
Com um fator de potência de0,8 atrasadoEsta unidade reproduz com precisão as condições de carga do mundo real, permitindo que os engenheiros verifiquem o desempenho, detectem fraquezas e evitem falhas antes que elas ocorram.

Construído paraaplicações industriais, marítimas, de data center e de energiaO banco de carga GROADA RL combina tecnologia de controle avançada, construção modular e sistemas de segurança robustos, proporcionando resultados de teste de carga consistentes, repetidos e seguros em qualquer ambiente.


Características principais & Vantagens

1. Simulação de carga RL verdadeira (fator de potência 0,8)

  • Simulaçõescomponentes resistivos e indutivossimultaneamente, proporcionando uma representação realista de sistemas motorizados e baseados em transformadores.

  • Ofertassomente resistivo, somente indutivooucombined RL operation for flexible testing modes.

  • Ideal for generator commissioning, factory acceptance testing (FAT), UPS maintenance, and system validation under lagging power factor conditions.

  • Helps ensure that your equipment performs efficiently under real operational demands—not just laboratory conditions.


2. Precision Step Control & Modular Design

  • Fine-tuned load step increments (e.g., 1 kW / 1 kVAR) for accurate load adjustment and gradual system ramp-up.

  • Modular resistive and inductive sections allow independent operation, easy calibration, and simplified servicing.

  • Parallel connection capability enables capacity expansion beyond 50 kVA for large-scale test systems.

  • Ensures smooth, stable transitions during load switching—reducing stress on test subjects and extending lifespan.


3. Advanced Control & Monitoring

  • Integrated digital PLC control system with high-precision data acquisition.

  • Real-time display and recording of voltage, current, power, power factor, frequency, and temperature.

  • Optional remote control and data logging via Ethernet / RS485 / wireless interfaces.

  • Automated test sequences with programmable ramp rates, dwell times, and step loads—ideal for repetitive testing and certification workflows.

  • Safety interlocks prevent unintended operation during testing or maintenance.


4. Robust Industrial Construction

  • Heavy-duty, powder-coated steel enclosure ensures durability and corrosion resistance in harsh environments.

  • Projetado paraindoor or outdoor operation, with high-efficiency forced-air cooling and thermostatically controlled fans.

  • All circuits are fully protected by overload breakers, fuses, and fault-detection systems.

  • Equipado comover-temperature, airflow failure, overload, emergency-stop, and load-dump protection mechanisms.

  • Engineered to operate continuously at full load without performance degradation, ensuring long service life and stable accuracy.


5. Prevents Generator “Wet Stacking” and Improves System Reliability

  • Regular load bank testing prevents wet stacking—the accumulation of unburned fuel and carbon deposits in diesel engines.

  • By simulating realistic load conditions, it ensures complete combustion and optimal generator efficiency.

  • Detects voltage drops, connection issues, insulation degradation, and cooling inefficiencies before they cause failures.

  • Essential for routine preventive maintenance in telecom, healthcare, data centers, and utility power plants.


6. Safety, Compliance & Long-Term Support

  • Built to meet or exceed international electrical and safety standards.

  • Each GROADA load bank undergoes full functional testing, calibration, and quality assurance before shipment.

  • Optional CE / ISO / UL-ready configurations available for compliance with global certification requirements.

  • Backed by GROADA’s comprehensive after-sales support, including commissioning assistance, spare parts supply, training, and remote diagnostics.


Especificações técnicas

ParâmetroEspecificação
ModeloAC 346V 50 kVA RL Load Bank
Rated Capacity50 kVA (resistive + inductive)
TensãoAC 346 V (3-phase, 50/60 Hz)
Fator de potência0.8 (lagging)
Load Steps1 kW / 1 kVAR increments (customizable)
Método de refrigeraçãoForced air cooling with automatic fan control
ProteçãoOver-temperature, airflow fault, overcurrent, emergency stop, short-circuit, load-dump
Control OptionsLocal control panel / Remote PLC / Network control
Enclosure RatingWeatherproof (IP54 / NEMA 3R optional)
Operating EnvironmentIndoor / Outdoor – -10 °C to +50 °C
ConstruçãoGalvanized steel with powder coating
ModularityExpandable capacity with parallel units

Aplicações

The GROADA AC 346V 50 kVA RL Load Bank is engineered for a broad range of industrial and mission-critical applications, including:

  • Generator commissioning and maintenance
    Validate generator output, voltage regulation, and governor response under full load.

  • UPS and inverter testing
    Simulate both linear and reactive loads to confirm backup system reliability.

  • Transformer and switchgear evaluation
    Test equipment under realistic load and power factor conditions.

  • Data center and telecom infrastructure
    Conduct performance and redundancy tests for critical power systems.

  • Marine and offshore platforms
    Verify generator performance in remote or sea-borne installations.

  • Industrial process power systems
    Assess electrical infrastructure before live production.


Why Choose GROADA

  • Experience: Years of specialized manufacturing in resistive and reactive load banks for international markets.

  • Expertise: Engineering team experienced in generator testing, industrial automation, and electrical system design.

  • Authority: Products conform to global standards and are deployed across power generation, defense, oil & gas, and data center sectors.

  • Trustworthiness: Proven field performance, factory quality control, and strong after-sales technical support.

Every GROADA load bank is a reflection of our commitment to innovation, precision, and reliability. We work closely with OEMs, service contractors, and system integrators to deliver tailored power-testing solutions worldwide.


Safety & Compliance Commitment

Electrical testing involves high energy levels and potential hazards. GROADA ensures every RL Load Bank is designed with multi-layer protection, adhering to the latest international safety directives.
All units are subjected to full-load endurance tests, insulation verification, and thermal stability trials prior to delivery—ensuring your system operates safely, efficiently, and within specification throughout its life cycle.


Maintenance & Support

GROADA offers complete post-delivery services, including:

  • On-site installation and commissioning support

  • Operator training and technical documentation

  • Calibration and periodic inspection programs

  • Spare parts availability and rapid global logistics

  • Remote technical assistance and diagnostics

We ensure long-term operational stability and minimum downtime, protecting your investment and productivity.


Call to Action

Ensure your power systems are always ready for real-world performance.
Contact GROADA today to discuss your AC 346V 50 kVA RL Load Bank requirements, request a quotation, or schedule an engineering consultation.
Trust GROADA—your global partner in professional load testing and power reliability.

Nosso Produto