Banco de carga del inversor GROADA-AC600V-25KW-RCD
The GROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-worl...
| modelo | AC220V-6KW-R | AC380El V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Potencia nominal | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Tamaño (ancho * profundidad * altura mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Peso | 25 kg | 80 kg | 130 kg | 180kg | 250 kg | 550kg | 650 kg | 1100kg |
| Corriente de entrada | 0-30A | 0-45A | 0-90A | 0-150A | 0-300A | 0-600A | 0-750A | 0-1500A |
| Carga mínima | 100W | 100W | 500W | 1 KW | 1 KW | 5KW | 10KW | 50 KW |
| Otra potencia mínima de carga se puede personalizar según los requisitos | ||||||||
| Voltaje de entrada | AC220 / 230V | AC380 / 400V | ||||||
| Otro voltaje de entrada se puede personalizar según los requisitos | ||||||||
| Potencia | PF = 1,0 | |||||||
| Precisión general | 3% (otros requisitos de precisión se pueden personalizar según los requisitos) | |||||||
| Modo de control | Manual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera) | |||||||
| Interfaz remota | RS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos) | |||||||
| Función de protección | Protección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente) | |||||||
| Fuente de alimentación de trabajo | AC220V | AC220V / 380V | AC380V | |||||
| Precisión de la pantalla | nivel 0,5 (otra precisión explícita se puede personalizar según los requisitos | |||||||
| Parámetros de visualización | Voltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos) | |||||||
| De manera segura fría | Adelante y fuera | Entrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos) | ||||||
| Nivel de protección | IP20 (otro nivel de protección se puede personalizar según los requisitos) | |||||||
| Color de apariencia | RAL7035 (otros colores se pueden personalizar según los requisitos) | |||||||
| Temperatura de trabajo | -10 ℃ ~ 55 ℃ | |||||||
| Humedad relativa | ≤95% RH | |||||||
| Altitud | ≤ 2500 m | |||||||
ElGROADA High-Performance Load Bank is designed to simulate electrical loads for testing and validating power systems. Widely used in generators, UPS systems, battery banks, and other power equipment, our load banks ensure reliability and stability under various operating conditions. Engineered for precision, they provide accurate load simulation for both AC and DC systems.
Power Range: From 10 kW to 5000 kW, suitable for small to large-scale testing needs.
Load Types:Soportaresistive (R), inductive (L), capacitive (C), RL, and RLC loads, as well as constant current, constant voltage, and constant power modes.
Control System: Advanced digital control technology enables remote monitoring, real-time adjustments, and precise load regulation.
Características de seguridad: Includes overload protection, overtemperature alarms, and automatic shutdown for enhanced operational safety.
Connectivity:Soportaremote control via Ethernet, RS485, and optional wireless monitoring.
Centros de datos: Test UPS and backup power systems under high loads to ensure system reliability and uptime.
Generator Sets: Simulate real-world electrical loads to validate generator performance and efficiency.
Renewable Energy Systems: Evaluate solar and wind power system output, ensuring optimal performance and energy efficiency.
Industrial Power Testing: Validate electrical distribution systems, motor drives, and battery storage units.
According to recent industry research, the global load bank market is growing rapidly, driven by increasing demand in data centers, renewable energy systems, and industrial power testing. GROADA load banks integrate cutting-edge technology to meet these evolving requirements.
XYZ Data Center, USA: Implemented GROADA load banks to perform comprehensive UPS system testing. The solution ensured stability under peak loads, improved system reliability, and reduced downtime risks.
ABC Renewable Energy Company, Germany: Used GROADA load banks to simulate variable solar and wind loads, optimizing system performance and validating energy storage solutions.
Reliable & Accurate: Precise load simulation ensures accurate testing results.
Advanced Technology: Digital control, remote monitoring, and smart automation.
Global Reach: Trusted by customers across Europe, North America, and Asia.
Customizable Solutions: Tailored load bank configurations to meet specific testing requirements.
Contact us today to learn more about GROADA Load Banks, request a quote, or discuss your specific testing needs.