Banco de carga del inversor GROADA-AC600V-25KW-RCD
The GROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-worl...
| modelo | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| Potencia nominal | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Corriente de entrada | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| Tamaño (ancho * profundidad * altura mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Peso | 50 kg | 80 kg | 100 kg | 130 kg | 200 kg | 300 kg | 350kg | 450 kg | 550kg |
| Voltaje de entrada | AC220 / 230V | AC380 / 400V | |||||||
| Otro voltaje de entrada se puede personalizar según los requisitos | |||||||||
| Carga mínima | 100W | 100W | 100W | 100W | 100W | 1 KW | 1 KW | 1 KW | 1 KW |
| Otra potencia mínima de carga se puede personalizar según los requisitos | |||||||||
| Precisión general | 3% (otros requisitos de precisión se pueden personalizar según los requisitos) | ||||||||
| factor de potencia | PF = 0,6 ~ 1,0 | ||||||||
| coeficiente de pico | 2 a 3 | ||||||||
| Modo de control | Manual local / ordenador anfitrión remoto (modo de control manual local: interruptor / botón / pantalla táctil de tres vías opcional, otros métodos se pueden personalizar según se requiera) | ||||||||
| Interfaz remota | RS232/RS485/USB/RJ45/CAN/GPIB (otros modos de interfaz se pueden personalizar según los requisitos) | ||||||||
| Función de protección | Protección contra paradas de emergencia, protección contra sobretemperaturas, protección contra bloqueo de carga del ventilador, protección contra puesta a tierra (seleccione protección contra sobrevoltaje, protección contra sobrecorriente, protección contra cortocircuitos, sobrecarga del ventilador, volumen de aire insuficiente) | ||||||||
| Fuente de alimentación de trabajo | AC220V | AC220V / AC380V | |||||||
| Precisión de la pantalla | Nivel 0,5 (otra precisión explícita se puede personalizar según los requisitos) | ||||||||
| Parámetros de visualización | Voltaje, corriente, potencia, frecuencia, factor de potencia, etc. (otros métodos explícitos se pueden personalizar según los requisitos) | ||||||||
| De manera segura fría | Entrada de aire lateral y salida de aire superior (otros métodos de salida de aire se pueden personalizar según los requisitos) | ||||||||
| Nivel de protección | IP20 (otro nivel de protección se puede personalizar según los requisitos) | ||||||||
| Color de apariencia | RAL7035 (otros colores se pueden personalizar según los requisitos) | ||||||||
| Temperatura de trabajo | -10 ℃ ~ 55 ℃ | ||||||||
| Humedad relativa | ≤95% RH | ||||||||
| Altitud | ≤ 2500 m | ||||||||
ElBanco de carga RCD GROADA AC600V-25kWes un dispositivo de prueba profesional diseñado para simular cargas eléctricas del mundo real parageneradores, sistemas UPS, inversores de potencia y otros equipos eléctricosAl replicar con precisión las cargas resistivas, inductivas y capacitivas, permite a los ingenieros verificar el rendimiento, la estabilidad y la seguridad del sistema en varias condiciones de funcionamiento.
Características clave:
Compatibilidad de alta tensiónSoporta hasta 600V AC para pruebas de alta y media tensión.
Carga ajustable de 25kW – Pasos de carga flexibles para simular múltiples escenarios.
RCD Safety Protection – Built-in Residual Current Device ensures operator and equipment safety.
Modular & Scalable – Easily expandable for higher capacity applications.
User-Friendly Control – Digital interface with local and remote monitoring options.
| Item | Especificación |
|---|---|
| modelo | AC600V-25kW RCD |
| Voltaje nominal | 0–600V AC |
| Potencia nominal | 25kW |
| Tipo de carga | Resistive / Inductive / Capacitive |
| Opciones de control | Digital / Manual / Remote interface |
| Accuracy | ±0.5% |
| Método de enfriamiento | Forced air cooling (optional water cooling) |
| Safety Protection | Overload, short-circuit, grounding, RCD protection |
| Dimensions / Weight | (Customize according to actual model) |
Load banks have become an essential tool in power reliability testing, especially for data centers, power plants, and mission-critical facilities.
Elglobal load bank market was valued at USD 288.17 million in 2024 and is projected to grow at a CAGR of 3.7% through 2032.
Another report estimates the market will reach USD 303.2 million by 2025yUSD 412.9 million by 2032 (CAGR ~4.5%).
North America accounted for over USD 106 million in 2024, maintaining steady growth.
Emerging trends include modular design, automated testing, hybrid load simulation (resistive + inductive), and remote monitoring solutions.
With years of expertise, GROADA integrates these cutting-edge technologies into our products, ensuring reliable, efficient, and safe load testing solutions for global customers.
Generator set performance testing and commissioning
UPS and battery system capacity verification
Inverter and VFD (Variable Frequency Drive) load response testing
Power equipment troubleshooting and preventive maintenance
Data center and critical power system validation
Power Plant Commissioning – A major utility company used the AC600V-25kW load bank to validate standby generator systems under 90% load, ensuring stable power delivery.
Data Center Validation – A Tier-III data center successfully simulated peak load conditions to test UPS redundancy and battery response.
Industrial Project – During factory acceptance testing, our load bank enabled engineers to simulate real operating conditions, reducing post-installation faults.
Operation Steps:
Verify system voltage compatibility.
Connect grounding and safety wiring.
Interface with local or remote control system.
Gradually apply load steps and monitor parameters.
Safety Precautions:
Do not exceed rated load and voltage range.
Always ensure proper grounding.
Only qualified personnel should operate.
Inspect wiring, fans, and resistors regularly.
Maintenance Recommendations:
Keep ventilation unobstructed.
Clean dust and debris periodically.
Perform annual calibration to maintain accuracy.
Avoid continuous operation at full load for extended periods.
Q1: What is an AC load bank?
A: An AC load bank simulates electrical loads to test power sources such as generators and UPS systems, ensuring they can perform reliably under real operating conditions.
Q2: Why is RCD protection important?
A: The built-in Residual Current Device (RCD) disconnects the circuit in case of leakage current, providing essential safety in high-voltage environments.
Q3: Is 25kW suitable for my application?
A: If your system requires up to 25kW testing at 600V, this model is ideal. For higher power requirements, multiple units can be connected in parallel.
Q4: What is the accuracy of this load bank?
A: It delivers precision testing with a load accuracy of ±0.5%, ensuring reliable measurement results.
Q5: Can I request a customized model?
A: Yes, GROADA offers customized high-power, modular, or multi-channel load banks tailored to specific project needs.
Built under ISO 9001 certified quality management system
CE / IEC / UL compliance available (model dependent)
Calibration and third-party test reports provided on request
Standard 12-month warranty with extended service options
Lifetime technical support and fast response service
Over 10 years of engineering experience in load bank manufacturing
Trusted by customers in power generation, aerospace, data centers, and renewable energy sectors
Proven track record with successful projects worldwide
Dedicated R&D team providing cutting-edge testing solutions