Banco de carga do inversor GROADA-AC600V-25KW-RCD
The GROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-worl...
| Modelo | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380O V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| Potência nominal | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Corrente de entrada | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| Tamanho (largura * profundidade * altura mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Peso | 50 quilos | 80 quilos | 100 quilos | 130 quilos | 200 quilos | 300 quilos | 350 quilos | 450 quilos | 550 quilos |
| Tensão de entrada | AC220 / 230V | AC380 / 400V | |||||||
| Outra tensão de entrada pode ser personalizada de acordo com os requisitos | |||||||||
| Carga mínima | 100W | 100W | 100W | 100W | 100W | 1kw | 1kw | 1kw | 1kw |
| Outra potência mínima de carga pode ser personalizada de acordo com os requisitos | |||||||||
| Precisão geral | 3% (outros requisitos de precisão podem ser personalizados de acordo com os requisitos) | ||||||||
| fator de potência | PF = 0,6 ~ 1,0 | ||||||||
| coeficiente de pico | 2 a 3 | ||||||||
| Modo de controle | Manual local / computador anfitrião remoto (modo de controle manual local: interruptor / botão / tela táctil trivial opcional, outros métodos podem ser personalizados conforme necessário) | ||||||||
| Interface remota | RS232/RS485/USB/RJ45/CAN/GPIB (outros modos de interface podem ser personalizados de acordo com os requisitos) | ||||||||
| Função de proteção | Proteção de parada de emergência, proteção contra sobretemperatura, proteção contra bloqueio de carga do ventilador, proteção contra a terra (selecione proteção contra sobretensão, proteção contra sobrecorrente, proteção contra curto-circuito, sobrecarga do ventilador, volume de ar insuficiente) | ||||||||
| Fonte de alimentação de trabalho | AC220V | AC220V / AC380V | |||||||
| Precisão da exibição | 0,5 nível (outra precisão explícita pode ser personalizada de acordo com os requisitos) | ||||||||
| Parâmetros de exibição | Tensão, corrente, potência, frequência, fator de potência, etc. (outros métodos explícitos podem ser personalizados de acordo com os requisitos) | ||||||||
| Frio certa maneira | Entrada de ar lateral e saída de ar superior (outros métodos de saída de ar podem ser personalizados de acordo com os requisitos) | ||||||||
| Nível de proteção | IP20 (outro nível de proteção pode ser personalizado de acordo com os requisitos) | ||||||||
| cor da aparência | RAL7035 (outras cores podem ser personalizadas de acordo com os requisitos) | ||||||||
| Temperatura de trabalho | -10 ℃ ~ 55 ℃ | ||||||||
| Umidade relativa | ≤95%RH | ||||||||
| Altitude | ≤ 2500 m | ||||||||
OBanco de carga RCD GROADA AC600V-25kWé um dispositivo de teste profissional projetado para simular cargas elétricas do mundo real parageradores, sistemas UPS, inversores de energia e outros equipamentos elétricos. Ao replicar com precisão cargas resistivas, indutivas e capacitivas, permite que os engenheiros verifiquem o desempenho do sistema, a estabilidade e a segurança sob várias condições operacionais.
Características principais:
Compatibilidade de alta tensãoSuporta até 600V AC para testes de alta e média tensão.
25kW carga ajustável – Passos de carga flexíveis para simular vários cenários.
RCD Safety Protection – Built-in Residual Current Device ensures operator and equipment safety.
Modular & Scalable – Easily expandable for higher capacity applications.
User-Friendly Control – Digital interface with local and remote monitoring options.
| Item | Especificação |
|---|---|
| Modelo | AC600V-25kW RCD |
| Tensão nominal | 0–600V AC |
| Potência nominal | 25kW |
| Tipo de carga | Resistive / Inductive / Capacitive |
| Control Options | Digital / Manual / Remote interface |
| Accuracy | ±0.5% |
| Método de refrigeração | Forced air cooling (optional water cooling) |
| Safety Protection | Overload, short-circuit, grounding, RCD protection |
| Dimensions / Weight | (Customize according to actual model) |
Load banks have become an essential tool in power reliability testing, especially for data centers, power plants, and mission-critical facilities.
Oglobal load bank market was valued at USD 288.17 million in 2024 and is projected to grow at a CAGR of 3.7% through 2032.
Another report estimates the market will reach USD 303.2 million by 2025 and USD 412.9 million by 2032 (CAGR ~4.5%).
North America accounted for over USD 106 million in 2024, maintaining steady growth.
Emerging trends include modular design, automated testing, hybrid load simulation (resistive + inductive), and remote monitoring solutions.
With years of expertise, GROADA integrates these cutting-edge technologies into our products, ensuring reliable, efficient, and safe load testing solutions for global customers.
Generator set performance testing and commissioning
UPS and battery system capacity verification
Inverter and VFD (Variable Frequency Drive) load response testing
Power equipment troubleshooting and preventive maintenance
Data center and critical power system validation
Power Plant Commissioning – A major utility company used the AC600V-25kW load bank to validate standby generator systems under 90% load, ensuring stable power delivery.
Data Center Validation – A Tier-III data center successfully simulated peak load conditions to test UPS redundancy and battery response.
Industrial Project – During factory acceptance testing, our load bank enabled engineers to simulate real operating conditions, reducing post-installation faults.
Operation Steps:
Verify system voltage compatibility.
Connect grounding and safety wiring.
Interface with local or remote control system.
Gradually apply load steps and monitor parameters.
Safety Precautions:
Do not exceed rated load and voltage range.
Always ensure proper grounding.
Only qualified personnel should operate.
Inspect wiring, fans, and resistors regularly.
Maintenance Recommendations:
Keep ventilation unobstructed.
Clean dust and debris periodically.
Perform annual calibration to maintain accuracy.
Avoid continuous operation at full load for extended periods.
Q1: What is an AC load bank?
A: An AC load bank simulates electrical loads to test power sources such as generators and UPS systems, ensuring they can perform reliably under real operating conditions.
Q2: Why is RCD protection important?
A: The built-in Residual Current Device (RCD) disconnects the circuit in case of leakage current, providing essential safety in high-voltage environments.
Q3: Is 25kW suitable for my application?
A: If your system requires up to 25kW testing at 600V, this model is ideal. For higher power requirements, multiple units can be connected in parallel.
Q4: What is the accuracy of this load bank?
A: It delivers precision testing with a load accuracy of ±0.5%, ensuring reliable measurement results.
Q5: Can I request a customized model?
A: Yes, GROADA offers customized high-power, modular, or multi-channel load banks tailored to specific project needs.
Built under ISO 9001 certified quality management system
CE / IEC / UL compliance available (model dependent)
Calibration and third-party test reports provided on request
Standard 12-month warranty with extended service options
Lifetime technical support and fast response service
Over 10 years of engineering experience in load bank manufacturing
Trusted by customers in power generation, aerospace, data centers, and renewable energy sectors
Proven track record with successful projects worldwide
Dedicated R&D team providing cutting-edge testing solutions