GROADA-DC1000V-200KW-R DC Ladelastbank
GROADA-DC1000V-200KW-R DC Charging Load_Shenzhen Guang Lu Da Electronics Co., Ltd. is a high-tech en...
| Nennleistung | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Größe (Breite * Tiefe * Höhe mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Gewicht | 25 kg | 80 kg | 130kg | 180 kg | 250 kg | 550kg | 650kg | 1100kg |
| Eingangsstrom | 0 bis 30A | 0 bis 45A | 0 bis 90A | 0 bis 150A | 0 bis 300A | 0 bis 600A | 0-750A | 0-1500A |
| Leistung | PF = 1,0 | |||||||
| Gesamtgenauigkeit | 3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden) | |||||||
| Steuermodus | Lokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden) | |||||||
| Fernschnittstelle | RS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden) | |||||||
| Schutzfunktion | Notstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen) | |||||||
| Genauigkeit der Anzeige | 0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden | |||||||
| Anzeigeparameter | Spannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden) | |||||||
| Kalte sichere Weise | Vorwärts und außen | Seitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden) | ||||||
| Schutzstufe | IP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden) | |||||||
| Erscheinungsfarbe | RAL7035 (andere Farben können entsprechend Anforderungen angepasst werden) | |||||||
| Arbeitstemperatur | -10 ℃ ~ 55 ℃ | |||||||
| Relative Luftfeuchtigkeit | ≤95% RH | |||||||
| Höhe | ≤ 2500 m | |||||||
As the global adoption of electric vehicles (EVs) accelerates, the demand for reliable and efficient EV charging infrastructure intensifies. Ensuring the performance and safety of charging stations is paramount. The GROADA-AC220V-60KW-R Charging Pile Load Bank emerges as a pivotal tool in this endeavor, offering a robust solution for simulating real-world load conditions and verifying the operational integrity of EV charging equipment.
Nennleistung: 60 kW
Eingangsspannung: AC 220V, 50Hz
Lasttyp: Resistive
Load Adjustment: Manual and remote control options
Schutzmerkmale: Overload, over-temperature, and short-circuit protection
Display: High-precision LCD meters for voltage, current, power, and power factor
Construction: Durable steel enclosure with IP67 protection rating
Cooling System: Efficient heat dissipation design
The load bank's ability to emulate various load conditions allows for comprehensive testing of EV charging stations. By adjusting the load in increments, it replicates the dynamic charging profiles encountered during actual EV charging sessions. This simulation aids in assessing the performance and reliability of charging equipment under different operational scenarios.
Adherence to international standards is crucial for the safety and interoperability of EV charging infrastructure. The GROADA-AC220V-60KW-R Load Bank supports compliance with key standards such as:
IEC 61851: Electric vehicle conductive charging system
SAE J1772: Standard for electrical connectors for electric vehicles
UL 2231-1: Safety standard for protection against electric shock and ground faults in EV charging systems
These standards ensure that charging stations are safe, efficient, and compatible with a wide range of EV models.
The load bank's built-in protection mechanisms safeguard both the testing equipment and the charging station under test. Features like overload, over-temperature, and short-circuit protection prevent potential damage during testing, ensuring the longevity and reliability of both the load bank and the charging infrastructure.
For manufacturers and developers, the load bank serves as an invaluable tool in the R&D phase. It allows for the evaluation of new charging technologies, the optimization of charging algorithms, and the identification of potential issues before deployment. This proactive approach accelerates innovation and enhances the quality of EV charging solutions.
The integration of load banks like the GROADA-AC220V-60KW-R into the testing protocols of EV charging stations aligns with the industry's shift towards stringent safety and performance standards. Governments and regulatory bodies are increasingly mandating regular testing and certification of charging infrastructure to ensure public safety and grid stability. By adopting such testing solutions, stakeholders can demonstrate compliance, mitigate risks, and contribute to the development of a robust EV charging ecosystem.
The GROADA-AC220V-60KW-R Charging Pile Load Bank stands as a testament to the industry's commitment to quality, safety, and innovation in EV charging infrastructure. Its advanced features, coupled with adherence to international standards, make it an indispensable tool for manufacturers, developers, and operators aiming to deliver reliable and efficient EV charging solutions. By investing in such testing equipment, stakeholders not only ensure the optimal performance of their charging stations but also contribute to the broader goal of sustainable and safe electric mobility.