GROADA-AC380V-50KW-R/RCD Wechselrichter Lastbank
The GROADA AC380V-50KW-R/RCD inverter test load bank is a high-performance testing device specifical...
| Modell | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| Nennleistung | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| Eingangsstrom | 0 bis 22A | 0 bis 45A | 0 bis 45A | 0 bis 90A | 0 bis 45A | 0 bis 300A | 0-450A | 0 bis 600A | 0-750A |
| Größe (Breite * Tiefe * Höhe mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Gewicht | 50 kg | 80 kg | 100 kg | 130kg | 200 kg | 300 kg | 350 kg | 450kg | 550kg |
| Eingangsspannung | AC220 / 230V | AC380 / 400V | |||||||
| Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden | |||||||||
| Minimale Belastung | 100W | 100W | 100W | 100W | 100W | 1KW | 1KW | 1KW | 1KW |
| Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden | |||||||||
| Gesamtgenauigkeit | 3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden) | ||||||||
| Leistungsfaktor | PF = 0,6 ~ 1,0 | ||||||||
| Spitzenkoeffizient | 2 bis 3 | ||||||||
| Steuermodus | Lokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden) | ||||||||
| Fernschnittstelle | RS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden) | ||||||||
| Schutzfunktion | Notstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen) | ||||||||
| Arbeitsstromversorgung | AC220V | AC220V / AC380V | |||||||
| Genauigkeit der Anzeige | 0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden) | ||||||||
| Anzeigeparameter | Spannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden) | ||||||||
| Kalte sichere Weise | Seitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden) | ||||||||
| Schutzstufe | IP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden) | ||||||||
| Erscheinungsfarbe | RAL7035 (andere Farben können entsprechend Anforderungen angepasst werden) | ||||||||
| Arbeitstemperatur | -10 ℃ ~ 55 ℃ | ||||||||
| Relative Luftfeuchtigkeit | ≤95% RH | ||||||||
| Höhe | ≤ 2500 m | ||||||||
Die GROADA AC600V 25 kW Inverter Load Bank ist eine speziell entwickelte Testlösung für Inverterhersteller, Labore und Leistungselektronik-Ingenieure, die eine genaue, wiederholbare und sichere Leistungsvalidierung benötigen. Es ist für moderne erneuerbare Energie- und Energiespeicheranwendungen konzipiert und bietet eine kontrollierte Umgebung, um reale Betriebsbedingungen zu simulieren und sicherzustellen, dass Wechselrichter strenge Zuverlässigkeits- und Effizienzstandards erfüllen.
Da sich Solar-, Batterie- und Mikronetzsysteme weiter ausbauen, ist die Zuverlässigkeit der Wechselrichter kritischer denn je geworden. Eine professionelle Lastbank ist unerlässlich, um Konstruktionsansprüche zu überprüfen, das Ausfallrisiko zu reduzieren und Kundenvertrauen aufzubauen.
Eine Wechselrichterlastbank ist ein Präzisionsgerät, das eine elektrische Last auf einen getesteten Wechselrichter auf sichere, kontrollierte Weise anwendet. Im Gegensatz zu passiven Feldtests, bei denen Geräte unvorhersehbaren Bedingungen ausgesetzt werden, liefert eine Lastbank stabile und einstellbare Lasten, die es den Ingenieuren ermöglichen:
Messung der Umwandlungseffizienz über verschiedene Laststufen hinweg
Analyse des thermischen Verhaltens des Wechselrichters im kontinuierlichen Betrieb
Überstrom-, Überspannung- und Schutzmerkmale validieren
Testleistung des Wechselrichters mit resistiven und reaktiven Lasten
Confirm grid-compliance functions such as anti-islanding and synchronization
This makes the GROADA AC600V 25 kW Load Bank an indispensable tool for inverter R&D, production quality assurance, and third-party certification.
600 V DC input and 25 kW power capacity — suitable for medium-scale PV and ESS inverters
Programmable load profiles — supports stepped, gradual, or dynamic load changes
Resistive, reactive, and inductive test modes — replicates real-world load conditions
Energy regenerative design — reduces wasted energy by feeding it back to the grid
High measurement accuracy — captures voltage, current, frequency, THD, and power factor with precision
Comprehensive protection — includes overcurrent, overvoltage, and thermal safeguards
Modular scalability — units can be combined for higher test power requirements
Industrial-grade reliability — robust cooling, durable construction, and long service life
By gradually stepping through load levels (10%, 20%, 50%, 100%), engineers can generate inverter efficiency curves and quantify power losses. This is essential for meeting regulatory requirements and optimizing design.
Sustained full-power operation simulates demanding field conditions. Engineers can verify cooling system performance, detect hot spots, and assess component aging over time.
Real electrical networks rarely operate with pure resistive loads. The ability to test with inductive or capacitive elements ensures accurate validation of power factor correction, stability, and reactive power handling.
Step loads, sudden drops, or rapid fluctuations test the robustness of inverter control loops. Load banks can uncover hidden weaknesses in firmware or protection systems that would otherwise appear only in the field.
Grid codes worldwide require inverters to handle abnormal conditions such as voltage dips, frequency shifts, or anti-islanding detection. A load bank allows safe simulation of these events to prove compliance with IEC, IEEE, and UL standards.
Solar Photovoltaic Inverters — verifying efficiency, MPP tracking, and safety under variable sunlight conditions
Energy Storage Systems (ESS) — testing bidirectional inverters and charge/discharge cycles
Microgrids and Hybrid Power Systems — ensuring reliable power sharing and seamless transitions
R&D Laboratories — supporting prototype evaluation and academic research in power electronics
Manufacturing QA — providing repeatable end-of-line testing before product shipment
Trusted Accuracy – Designed with precision instrumentation for reliable test results.
Energy Savings – Regenerative design minimizes waste and reduces operational costs.
Operator Safety – Integrated protections and emergency shutoffs ensure safe operation.
Flexibility – Adaptable to multiple inverter types, from residential PV to industrial storage.
Future-Proof – Modular capacity supports expansion as test demands grow.
The GROADA 25 kW Inverter Load Bank is engineered to support compliance testing with major global standards, including:
IEC 62116 – Test procedure of islanding prevention measures for grid-connected PV inverters
IEC 61000 – Electromagnetic compatibility requirements
IEEE 1547 – Standard for interconnection and interoperability of distributed resources
UL 1741 – Inverters, converters, and controllers for use in distributed energy resources
Meeting these standards is essential for manufacturers aiming to enter international markets with certified products.
GROADA specializes in advanced load bank solutions for the renewable energy and power electronics industries. Our engineering team brings years of field experience and technical expertise, ensuring products that combine innovation, durability, and cost efficiency.
By partnering with GROADA, customers gain more than equipment — they gain a trusted testing partner committed to quality, reliability, and global support.
The GROADA AC600V 25 kW Inverter Load Bank empowers inverter developers, manufacturers, and testing laboratories with a reliable, precise, and efficient tool for performance validation. From efficiency mapping to grid-compliance testing, it delivers the insights needed to design robust, safe, and market-ready inverters.
Investing in a professional load bank is not just about compliance — it is about ensuring long-term reliability, customer satisfaction, and competitive advantage in the fast-growing renewable energy sector.