GROADA-AC220V-15KW-RLC Lastbank Hersteller
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| Modell | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Nennleistung | RLC = 10KVA | RLC = 30KVA | RLC = 60KVA | RLC = 100KVA | RLC = 200KVA | RLC = 300KVA |
| R = 10KW; L = 10KVA C = 10KVA | R = 30KW; L = 30KVA; C = 30KVA | R = 60KW; L = 60KVA; C = 60KVA | R = 100KW; L = 100KVA; C = 100KVA | R = 200KW; L = 200KVA; C = 200KVA | R = 300KW; L = 300KVA; C = 300KVA | |
| Andere Leistung kann entsprechend Anforderungen angepasst werden | ||||||
| Größe (Breite * Tiefe * Höhe mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Gewicht | 120 kg | 380kg | 580kg | 880kg | 1500 kg | 2500kg |
| Eingangsspannung | AC220 / 230V | AC380 / 400V | ||||
| Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden | ||||||
| Eingangsstrom | 0 bis 45A | 0 bis 45A | 0 bis 90A | 0 bis 150A | 0 bis 300A | 0-450A |
| Minimale Belastung | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 1KW; L = 1KVA; C = 1KVA | R = 1KW; L = 1KVA; C = 1KVA |
| Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden | ||||||
| Leistungsfaktor | PF = 0,1 ~ 1,0 (anderer Leistungsfaktor kann entsprechend Anforderungen angepasst werden) | |||||
| Gesamtgenauigkeit | 3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden) | |||||
| Steuermodus | Lokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden) | |||||
| Fernschnittstelle | RS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden) | |||||
| Schutzfunktion | Notstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen) | |||||
| Arbeitsstromversorgung | AC220V | AC220V / 380V | AC380V | |||
| Genauigkeit der Anzeige | 0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden) | |||||
| Anzeigeparameter | Spannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden) | |||||
| Kalte sichere Weise | Seitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden) | |||||
| Schutzstufe | IP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden) | |||||
| Erscheinungsfarbe | RAL7035 (andere Farben können entsprechend Anforderungen angepasst werden) | |||||
| Arbeitstemperatur | -10 ℃ ~ 55 ℃ | |||||
| Relative Luftfeuchtigkeit | ≤95% RH | |||||
| Höhe | ≤ 2500 m | |||||
Die GROADA RLC Load Bank ist eine Spitzenlösung für die strenge Prüfung von elektrischen Energiesystemen. Durch die genaue Simulation von resistiven (R), induktiven (L) und kapazitiven (C) Belastungen bietet diese Lastbank eine realistische Darstellung von realen Betriebsbedingungen. Es ist ein wesentliches Werkzeug für Ingenieure, Techniker und Anlagenmanager, die die Zuverlässigkeit, Effizienz und Sicherheit von Generatoren, UPS-Systemen und anderen kritischen Stromausrüstungen gewährleisten wollen.
In der sich schnell entwickelnden Energielandschaft von heute, wo die Integration erneuerbarer Energien, kritische Infrastruktur und industrielle Automatisierung stabilen und zuverlässigen Strom erfordern, bietet die GROADA RLC Load Bank Präzision, Vielseitigkeit und Einhaltung globaler Standards.
Die GROADA RLC Load Bank kann resistive, induktive und kapazitive Belastungen gleichzeitig anwenden. Dadurch wird sichergestellt, dass Leistungssysteme unter Bedingungen getestet werden, die reale Betriebsumgebungen genau nachahmen, einschließlich schwankender Lasten, Harmoniken und unterschiedlicher Leistungsfaktoren.
Moderne elektrische Systeme erfordern flexible Lastprüfungen. Die GROADA Lastbank ermöglicht Leistungsfaktoreinstellungen von 0,1 bis 1,0, was die Bewertung der Systemleistung unter Lagging-, Leading- und Unity-Leistungsfaktoren ermöglicht. Dies ist besonders wichtig für Industriegeräte, UPS-Systeme und erneuerbare Energiequellen.
Die RLC Load Bank ist für globale Anwendungen konzipiert und unterstützt sowohl einphasige als auch dreiphasige Wechselstromsysteme:
Einphasen: 120V, 220V, 230V, 240V (50/60Hz)
Dreiphase: 208V, 380V, 400V, 415V (50/60Hz)
Dies eignet sich für internationale Einsätze in Rechenzentren, Industrieanlagen und Telekommunikationsanlagen.
Ausgestattet mit hochpräzisen digitalen Zählern überwacht die Lastbank:
Spannung und Strom
Aktive, reaktive und scheinbare Kraft
Leistungsfaktor
Energieverbrauch
Frequenz
Diese Echtzeitmessungen ermöglichen es den Ingenieuren, fundierte Entscheidungen zu treffen und die Systemleistung genau zu validieren.
The GROADA RLC Load Bank offers both local and remote control:
Local Operation: Intuitive touchscreen interface for easy load adjustment.
Remote Operation: Full computer-based control for monitoring, scheduling, and data logging, improving operational efficiency and safety.
Resistive load accuracy: ±5%
Inductive and capacitive load accuracy: ±10%
These specifications guarantee precise load application, ensuring test results are reliable and reproducible.
The GROADA RLC Load Bank is widely used across multiple sectors:
Uninterrupted power is critical in data centers. The RLC Load Bank allows operators to test backup generators and UPS systems under full-load conditions, ensuring seamless operation during power outages.
Telecom facilities depend on emergency power systems for network continuity. The load bank enables rigorous testing of power infrastructure, preventing service interruptions and safeguarding critical communication lines.
Production lines and heavy machinery rely on stable power. The GROADA load bank evaluates system robustness, identifies weaknesses, and minimizes downtime risks, ultimately protecting operational continuity and revenue.
Mission-critical operations require power systems that perform flawlessly under extreme conditions. The RLC Load Bank validates generators, UPS, and control systems, ensuring readiness in defense and aerospace applications.
As solar, wind, and hybrid energy solutions grow in adoption, testing their interaction with grid systems becomes essential. The RLC Load Bank simulates variable loads to evaluate system stability, voltage regulation, and power factor correction.
The GROADA RLC Load Bank adheres to globally recognized standards:
IEEE 1547: Distributed energy resource interconnection and performance testing.
IEEE 112.3 & 112.5: UPS performance verification standards.
NFPA 110: Emergency and standby power system testing and maintenance.
ISO 8528: Reciprocating engine-driven generator testing procedures.
IEC 62040: Performance and test requirements for UPS systems.
UL 1008: Safety requirements for transfer switches.
These certifications ensure that testing meets regulatory requirements, enabling safe deployment in diverse industries worldwide.
By simulating real operational loads, potential weaknesses in generators, alternators, batteries, and control panels are detected before they cause system failures.
Proactive testing reduces unexpected maintenance costs and extends equipment lifespan by identifying issues early.
Regular load testing ensures uninterrupted power supply, critical in healthcare, data centers, and telecom facilities.
Meeting ISO, IEEE, NFPA, and UL standards ensures organizations maintain compliance and safety across all operations.
By preventing downtime and optimizing power system performance, organizations save on energy costs, maintenance expenses, and emergency repair charges.
| Parameter | Spezifikation |
|---|---|
| Lasttyp | Resistive, Inductive, Capacitive |
| Leistungsfaktor | 0.1 – 1.0 Adjustable |
| Spannung | Single-phase 120V/220V/230V/240V, Three-phase 208V/380V/400V/415V |
| Frequenz | 50/60Hz |
| Measurement Accuracy | ±5% R, ±10% L/C |
| Control | Local touchscreen, Remote computer control |
| Dimensions | Customizable per model |
| Kühlung | Forced air or natural convection options |
| Sicherheitsmerkmale | Overload protection, emergency stop, thermal sensors |
GROADA has decades of experience in designing and manufacturing load banks trusted by industries worldwide. Our products are:
Reliable: Engineered for precision and long-term durability.
Flexible: Suitable for a wide range of power systems and international voltage standards.
Safe: Compliant with global electrical safety standards.
User-Friendly: Advanced digital interface for easy monitoring and control.
Organizations from data centers to military bases rely on GROADA load banks to validate and maintain their electrical systems efficiently.
In an era where uninterrupted power supply is mission-critical, the GROADA RLC Load Bank provides unmatched precision, versatility, and reliability. By simulating realistic electrical loads, it ensures that generators, UPS systems, and industrial power infrastructures operate optimally under any condition.
Elevate your power testing capabilities with GROADA – the professional choice for engineers and organizations that demand accuracy, safety, and performance.