GROADA-DC1000V-200KW-R DC Ladelastbank
GROADA-DC1000V-200KW-R DC Charging Load_Shenzhen Guang Lu Da Electronics Co., Ltd. is a high-tech en...
| Nennleistung | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Größe (Breite * Tiefe * Höhe mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Gewicht | 25 kg | 80 kg | 130kg | 180 kg | 250 kg | 550kg | 650kg | 1100kg |
| Eingangsstrom | 0 bis 30A | 0 bis 45A | 0 bis 90A | 0 bis 150A | 0 bis 300A | 0 bis 600A | 0-750A | 0-1500A |
| Leistung | PF = 1,0 | |||||||
| Gesamtgenauigkeit | 3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden) | |||||||
| Steuermodus | Lokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden) | |||||||
| Fernschnittstelle | RS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden) | |||||||
| Schutzfunktion | Notstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen) | |||||||
| Genauigkeit der Anzeige | 0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden | |||||||
| Anzeigeparameter | Spannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden) | |||||||
| Kalte sichere Weise | Vorwärts und außen | Seitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden) | ||||||
| Schutzstufe | IP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden) | |||||||
| Erscheinungsfarbe | RAL7035 (andere Farben können entsprechend Anforderungen angepasst werden) | |||||||
| Arbeitstemperatur | -10 ℃ ~ 55 ℃ | |||||||
| Relative Luftfeuchtigkeit | ≤95% RH | |||||||
| Höhe | ≤ 2500 m | |||||||
As the global electric vehicle (EV) market accelerates, the demand for reliable and efficient EV charging infrastructure intensifies. Ensuring the performance and safety of charging stations is paramount. The GROADA DC750V-50KW-R Charging Pile Load Bank emerges as a pivotal solution, offering advanced testing capabilities to simulate real-world charging scenarios.
Voltage Range: Supports up to 750V DC, accommodating a diverse range of EV charging systems.
Leistungskapazität: Delivers a maximum load of 50kW, suitable for testing both low and high-power charging stations.
Lastart: Features a resistive load design, providing stable and accurate simulations of actual charging conditions.
Steuerschnittstelle: Equipped with an intuitive touch screen interface, allowing for seamless operation and real-time monitoring.
Sicherheitsmerkmale: Incorporates overcurrent, overvoltage, and thermal protection mechanisms to ensure the safety of both equipment and personnel.
The GROADA DC750V-50KW-R Load Bank serves multiple critical functions in the development and maintenance of EV charging stations:
Design Validation: Engineers utilize the load bank to simulate diverse EV charging profiles, ensuring that charging stations are designed to handle expected loads efficiently.
Performance Testing: Regular testing with the load bank verifies that charging stations maintain optimal performance under varying load conditions.
Compliance Assurance: Facilitates adherence to international standards such as IEC 61851 and national regulations, streamlining the certification process.
Diagnostic Tool: Serves as an essential tool for identifying and rectifying issues in charging equipment, thereby minimizing downtime and enhancing reliability.
Adhering to established standards is crucial for ensuring the safety and efficiency of EV charging stations:
IEC 61851: Specifies general requirements for EV charging systems, encompassing safety measures and communication protocols.
GB/T 20234.2: Chinese national standard outlining the technical requirements for AC/DC charging connectors and communication protocols.
UL 2202: Standard for the safety of EV charging equipment in the United States, focusing on electrical and mechanical safety aspects.
Utilizing the GROADA DC750V-50KW-R Load Bank ensures that testing procedures align with these standards, promoting the development of safe and reliable charging infrastructure.
The GROADA DC750V-50KW-R Charging Pile Load Bank is an indispensable tool for the EV charging industry. By providing accurate simulations of real-world charging scenarios, it enables manufacturers and operators to deliver high-quality, compliant, and safe charging solutions. Investing in such advanced testing equipment is essential for the sustainable growth of the EV industry and the transition towards a greener future.