GROADA-AC220V-12KW-R Widerstandslastbank
The GROADA AC220V 12KW Resistive Load Bank is engineered for rigorous testing of AC power sources, i...
| Modell | AC220V-6KW-R | AC380V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Nennleistung | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Größe (Breite * Tiefe * Höhe mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Gewicht | 25 kg | 80 kg | 130kg | 180 kg | 250 kg | 550kg | 650kg | 1100kg |
| Eingangsstrom | 0 bis 30A | 0 bis 45A | 0 bis 90A | 0 bis 150A | 0 bis 300A | 0 bis 600A | 0-750A | 0-1500A |
| Minimale Belastung | 100W | 100W | 500W | 1KW | 1KW | 5KW | 10kw | 50 KW |
| Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden | ||||||||
| Eingangsspannung | AC220 / 230V | AC380 / 400V | ||||||
| Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden | ||||||||
| Leistung | PF = 1,0 | |||||||
| Gesamtgenauigkeit | 3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden) | |||||||
| Steuermodus | Lokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden) | |||||||
| Fernschnittstelle | RS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden) | |||||||
| Schutzfunktion | Notstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen) | |||||||
| Arbeitsstromversorgung | AC220V | AC220V / 380V | AC380V | |||||
| Genauigkeit der Anzeige | 0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden | |||||||
| Anzeigeparameter | Spannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden) | |||||||
| Kalte sichere Weise | Vorwärts und außen | Seitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden) | ||||||
| Schutzstufe | IP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden) | |||||||
| Erscheinungsfarbe | RAL7035 (andere Farben können entsprechend Anforderungen angepasst werden) | |||||||
| Arbeitstemperatur | -10 ℃ ~ 55 ℃ | |||||||
| Relative Luftfeuchtigkeit | ≤95% RH | |||||||
| Höhe | ≤ 2500 m | |||||||
DieGROADA AC400V-1000KW-R Widerstandsbelastungsbankist eine leistungsstarke elektrische Prüflösung für großflächige Stromanlagen. Diese Ladebank ist mit Präzisionstechnik und fortschrittlichen Sicherheitsfunktionen gebaut und ermöglicht es Ingenieuren und Technikern, elektrische Belastungen genau zu simulieren, um sicherzustellen, dass Generatoren, UPS-Systeme und andere Stromanlagen unter realen Bedingungen zuverlässig funktionieren.
Ideal für den Einsatz im Innen- und Außenbereich, ist das Modell AC400V-1000KW-R so konzipiert, dassKonsistente, sichere und wiederholbare Ergebnissein einer Vielzahl von Anwendungen in den Industrie-, Handels- und Erneuerbaren Energiesektoren.
Fähig zur Lieferung1000 kW Widerstandslastbei 400V Wechselstrom, so dass es für die Prüfung von Hochleistungsgeneratoren und großen elektrischen Systemen geeignet ist.
Unterstützt sowohl kontinuierliche als auch intermittierende Lastprüfungen und gewährleistet Flexibilität für verschiedene Testszenarien.
Features finely segmented load steps, enabling precise simulation of electrical loads from minimal to maximum capacity.
Facilitates accurate power factor and efficiency analysis, helping optimize generator and UPS performance.
Designed with a weather-resistant steel enclosure for long-lasting performance in harsh industrial environments.
High-quality resistive elements ensure stable heat dissipation, preventing overheating during extended testing periods.
Ausgestattet mitintuitive control panels displaying real-time voltage, current, power, and energy consumption.
Allows operators to monitor system performance and adjust loads dynamically for thorough testing and diagnostics.
Integriertovercurrent protection, thermal cutoff, and emergency shutdown functions to safeguard both equipment and personnel.
Ensures compliance with international electrical safety standards, providing peace of mind during high-power testing operations.
The AC400V-1000KW-R Resistive Load Bank is versatile, addressing the growing demand for reliable power testing across multiple industries:
Generator-Tests
Validates the capacity, efficiency, and operational stability of backup and prime power generators.
Supports predictive maintenance programs by identifying potential performance issues before deployment.
UPS and Energy Storage Systems
Tests uninterruptible power supply systems under varying loads to ensure reliability during outages.
Assists in verifying energy storage integration in critical facilities such as data centers and hospitals.
Data Center and Mission-Critical Facilities
Ensures uninterrupted operations by simulating peak loads for server rooms and networking equipment.
Helps optimize power distribution and cooling systems for maximum efficiency.
Renewable Energy and Grid Integration
Supports testing for solar inverters, wind generators, and hybrid power systems.
Evaluates performance under variable load conditions to confirm grid compatibility and stability.
Industrial and Commercial Power Systems
Assesses high-capacity motors, compressors, and industrial machinery under full-load conditions.
Reduces risk of unexpected downtime by verifying electrical infrastructure before operation.
Dieglobal load bank market is projected to grow steadily, driven by the increasing complexity and critical nature of power systems in various sectors. According to industry research:
The market is expected to rise from $300 million in 2025 to over $380 million by 2032, reflecting a growing demand for reliable power testing solutions.
Key drivers include the expansion of data centers, renewable energy integration, and stricter compliance requirements for mission-critical facilities.
Advanced digital load banks, like the GROADA AC400V-1000KW-R, are increasingly preferred due to their enhanced precision, real-time monitoring, and improved safety standards.
GROADA is recognized as a leading innovator in load bank technology, combining decades of engineering expertise with cutting-edge manufacturing. By choosing the AC400V-1000KW-R Resistive Load Bank, customers benefit from:
Unmatched reliability: Built to withstand demanding industrial conditions.
High accuracy: Fine-tuned load control for precise power testing.
Comprehensive support: Technical guidance and global after-sales service for seamless operation.
Industry compliance: Designed to meet international safety and electrical standards.
This makes GROADA a trusted partner for engineers, power system operators, and facility managers worldwide, ensuring that critical electrical systems perform at their best.
Spannung:400 V Wechselstrom
Leistungskapazität: 1000 kW
Lastart:Widerstandsfähig
Ladeschritte: Fine-grained, adjustable
Kühlung: Forced air / high-efficiency heat dissipation
Control: Digital display and intuitive interface
Safety: Overcurrent protection, thermal shutdown, emergency stop
DieGROADA AC400V-1000KW-R Widerstandsbelastungsbank is more than just a testing device; it is a comprehensive solution for modern power system verification and reliability assurance. Its combination of high power capacity, precision control, safety features, and durability makes it an indispensable tool for power engineers and facility managers aiming for optimal system performance, efficiency, and longevity.