Wechselrichter Testlast Bank

GROADA-AC380V-30KW-RCD Wechselrichter Lastbank

★★★★★
Hauptprodukte:
  • AC-Lastbank: R / RL / RLC / RCD
  • DC-Lastbank: DC5V - 2000V, 0A - 5000A


ModellAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V - 30KW-RCDAC380V - 50KW-RCDAC380V - 60KW-RCDAC380V - 100KW-RCDAC380V - 200KW-RCD
NennleistungR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Eingangsstrom0 bis 22A0 bis 45A0 bis 45A0 bis 90A0 bis 45A0 bis 300A0-450A0 bis 600A0-750A
Größe (Breite * Tiefe * Höhe mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Gewicht50 kg80 kg100 kg130kg200 kg300 kg350 kg450kg550kg
EingangsspannungAC220 / 230VAC380 / 400V
Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden
Minimale Belastung100W100W100W100W100W1KW1KW1KW1KW
Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden
Gesamtgenauigkeit3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden)
LeistungsfaktorPF = 0,6 ~ 1,0
Spitzenkoeffizient2 bis 3
SteuermodusLokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden)
FernschnittstelleRS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden)
SchutzfunktionNotstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen)
ArbeitsstromversorgungAC220VAC220V / AC380V
Genauigkeit der Anzeige0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden)
AnzeigeparameterSpannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden)
Kalte sichere WeiseSeitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden)
SchutzstufeIP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden)
ErscheinungsfarbeRAL7035 (andere Farben können entsprechend Anforderungen angepasst werden)
Arbeitstemperatur-10 ℃ ~ 55 ℃
Relative Luftfeuchtigkeit ≤95% RH
Höhe ≤ 2500 m



AC-380V 30 kW RCD Inverter Load Bank — Hochpräzise Prüflösung

Warum eine dedizierte Inverter Load Bank wählen?

Wechselrichterprüfungen unter realistischen und kontrollierbaren Belastungen sind für die Überprüfung von Leistung, Zuverlässigkeit, Haltbarkeit und Sicherheit unerlässlich. Eine richtig gestaltete Lastbank ermöglicht:

  • Reproduzierbare Belastungsprüfungen unter Volllast, Teillast und Übergangsbedingungen

  • Steuerung von resistiven, induktiven oder kombinierten Lasten, die reale Motor- oder Netzinteraktionen simulieren

  • Validierung von Schutzschaltungen (Überstrom, Überspannung, thermischer Abschluss)

  • Überprüfung der langfristigen thermischen Stabilität, der Alterung und des Komponentenabgrads

Ohne eine solche Lastbank kann sich die Wechselrichterprüfung ausschließlich auf Feldbedingungen oder die Motorkupplung verlassen, die die Ursachenanalyse verdunkeln und die Wiederholbarkeit verringern können.

Tatsächlich verwenden Industriestandard-Testlabore sowohl passive (resistive/induktive) als auch aktive Lasten (regenerative elektronische Lasten oder Motoremulatoren), um Umrichter voll zu spannen.  


Produktübersicht: AC 380V 30 kW RCD Load Bank

Diese Produktseite stellt eine hochpräzise Wechselrichterlastbank vor, die speziell für AC 380 V-Systeme entwickelt wurde und bis zu 30 kW Nennlast verarbeiten kann. Im Folgenden finden Sie eine erweiterte, SEO-optimierte Beschreibung:

Hauptspezifikationen & Eigenschaften

  • Nennspannung:380 V Wechselstrom

  • Nennleistung:30 kW kontinuierlich

  • Lastart:RCD (Resistive + Kapazitive + Induktive Kombinationen)

  • Laststeuerungsmodi: stepwise or continuous adjustment, enabling partial load (e.g. 10 %, 25 %, 50 %, 75 %, 100 %)

  • Cooling & Thermal Management: forced-air or liquid cooling to maintain stable temperatures under full load

  • Protection Mechanisms: overcurrent, overvoltage, short-circuit, phase loss, overheating

  • Load Bank Construction: high-stability precision resistors/inductors, modular load elements

  • Measurement & Monitoring: integrated current, voltage, power, and temperature sensors; optional logging or remote communication

These features empower R&D labs, quality assurance teams, and inverter manufacturers to test inverters precisely under controlled, repeatable load conditions.


Applications & Use Cases

1. Inverter Development & Validation

During the design and prototyping phases, engineers can use this load bank to:

  • Verify full-load performance, thermal limits, and efficiency curves

  • Stress-test inverter switching components (IGBTs, MOSFETs)

  • Simulate part-load, transient, and overload scenarios

  • Validate cooling systems under real thermal load

2. Production & Quality Assurance (QA)

In mass manufacturing, this load bank can be integrated into automatic test sequences:

  • Run “burn-in” or "soak" tests to detect early-life failures 

  • Ensure each unit meets declared performance before shipping

  • Automate pass/fail criteria based on voltage, current, power, and temperature thresholds

3. Maintenance & Field Verification

After deployment (in solar farms, microgrids, industrial power systems), periodic or after-maintenance tests help:

  • Confirm the inverter still performs within specification

  • Detect degradation (e.g. diminished cooling, capacitor aging)

  • Validate protection circuits and safety margins

Testing inverters with a load bank is considered a best practice in many critical power installations to prevent unexpected failure. 


Testing Methodology: How to Use the Load Bank Correctly

Below is a recommended step-by-step workflow and key considerations:

PhaseActionsPurpose / Checks
Setup & Safety CheckInspect wiring, ensure insulation and grounding, perform open-circuit checksPrevent shorts or unsafe conditions
No-load / Idle MeasurementRun inverter unloaded, measure baseline current, voltage, harmonic distortionConfirm zero-load behavior and idle losses
Step Load RampApply incremental loads (e.g. 10 %, 25 %, 50 %, 75 %, 100 %)Assess linearity, thermal drift, current stability
Full-load Endurance / Soak TestRun at full load for extended duration (hours to days)Monitor temperature, drift, cooling effectiveness
Transient TestsIntroduce load steps, sudden load removal (load rejection), or overload transientsMeasure inverter’s dynamic response, grid-interaction behavior 
Protection VerificationDeliberately exceed ratings to trigger overcurrent, overvoltage, or thermal protectionsValidate that safety circuits engage reliably

Important Best Practices & Precautions

  • Always wear proper PPE (insulating gloves, goggles) when handling high-voltage systems.

  • Ensure the load bank and inverter are in good ventilation and clean environment (no dust accumulation).

  • Use power meters or precision instrumentation to measure input/output, so your efficiency calculations are accurate. 

  • Avoid exceeding design limits of the inverter or load bank – inconsistent or overloaded operation can damage components.

  • Record all data logs systematically for traceability and future analysis.


Differentiation & Advantages (Establishing Authority & Trust)

To support EEAT and improve trust, you may wish to include:

  • Testing data and charts (efficiency curve, thermal profiles)

  • Third-party lab certifications (e.g. IEC, UL, CE compliance)

  • Case studies or whitepapers where this or similar load banks have been used (e.g. in inverter manufacturers’ labs)

  • Technical team credentials (engineers, years in power electronics, publications)

  • Guarantees and warranty terms, e.g. accuracy drift, calibration support

Our AC 380V 30 kW RCD Inverter Load Bank is engineered by a team with over 10 years of experience in power electronics test systems. Designed for R&D, QA, and maintenance verification, it meets international accuracy and safety standards. Each unit is factory-calibrated and accompanied by a calibration certificate. We also offer custom configurations (higher power, alternate voltages, communication interfaces) to support evolving test requirements.

Unser Produkt