GROADA-AC346V-50KVA-RL Resistive induktive Belastungsbox

★★★★★
Hauptprodukte:
  • AC-Lastbank: R / RL / RLC / RCD
  • DC-Lastbank: DC5V - 2000V, 0A - 5000A


ModellAC220V-10KVA-RLAC380V-30KVA-RLAC380V-60KVA-RLAC380V-100KVA-RLAC380V-300KVA-RLAC380V-500KVA-RLAC380V-1000KVA-RL
NennleistungRL = 10KVARL = 30KVARL = 60KVARL = 100KVARL = 300KVARL = 500KVARL = 1000KVA
R = 10KW; L = 6KVAR = 30KW; L = 18KVAR = 60KW; L = 36KVAR = 100KW; L = 60KVAR = 300KW; L = 180KVAR = 500KW; L = 300KVAR = 1000KW; L = 600KVA
Eingangsstrom0 bis 45A0 bis 45A0 bis 90A0 bis 150A0-450A0-750A0-1500A
Größe (Breite * Tiefe * Höhe mm)480*600*277480*600*360500*750*1000600*850*1000700*1000*16501100*1400*17001100*1500*1900
Gewicht25 kg40 kg80 kg130kg250 kg550kg750 kg
Minimale Belastung100W100W100W500W1KW5KW10kw
Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden
EingangsspannungAC220 / 230VAC380 / 400V
Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden
LeistungsfaktorPF = 0,8/1,0 (anderer Leistungsfaktor kann nach Anforderungen angepasst werden)
Gesamtgenauigkeit3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden)
SteuermodusLokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden)
FernschnittstelleRS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden)
SchutzfunktionNotstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen)
ArbeitsstromversorgungAC220VAC220V / 380VAC380V
Genauigkeit der Anzeige0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden)
AnzeigeparameterSpannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden)
Kalte sichere WeiseSeitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden)
SchutzstufeIP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden)
ErscheinungsfarbeRAL7035 (andere Farben können entsprechend Anforderungen angepasst werden)
Arbeitstemperatur-10 ℃ ~ 55 ℃
Relative Luftfeuchtigkeit ≤95% RH
Höhe ≤ 2500 m



AC 346V 50 kVA RL Widerstands-/Induktivlastbank

Präzision, Zuverlässigkeit und reale Leistungstests von GROADA


Übersicht

DieGROADA AC 346V 50 kVA RL Lastbankist ein hochpräzises Testsystem, das entworfen wurde, um beide zu simulierenresistive und induktive Belastungenfür Generatoren, UPS-Systeme, Turbinen und Stromnetze.
Mit einem Leistungsfaktor von0,8 RückstandDiese Einheit reproduziert genau reale Belastungsbedingungen, so dass Ingenieure die Leistung überprüfen, Schwächen erkennen und Ausfälle verhindern können, bevor sie auftreten.

Gebaut fürIndustrie-, Marine-, Rechenzentrum- und EnergieanwendungenDie GROADA RL Load Bank kombiniert fortschrittliche Steuertechnik, modulare Konstruktion und robuste Sicherheitssysteme und liefert konsistente, wiederholbare und sichere Lastprüfungsergebnisse in jeder Umgebung.


Hauptmerkmale & Vorteile

1. Wahre RL-Lastsimulation (0,8 Leistungsfaktor)

  • Simuliertsowohl resistive als auch induktive Komponentengleichzeitig eine realistische Darstellung von motorgetriebenen und transformatorbasierten Systemen.

  • Angebotenur resistiv, nur induktivoderkombinierter RL-Betriebfür flexible Testmodi.

  • Ideal für die Inbetriebnahme von Generatoren, Fabrik-Akzeptanzprüfungen (FAT), UPS-Wartung und Systemvalidierung unterverzögerter LeistungsfaktorBedingungen.

  • Sie stellen sicher, dass Ihre Ausrüstung unter realen Betriebsanforderungen – nicht nur unter Laborbedingungen – effizient funktioniert.


2. Präzisionsschrittsteuerung & Modulares Design

  • Feinabstimmte Laststufzungen (z.B. 1 kW / 1 kVAR) fürpräzise Lastanpassungund schrittweisen Systemaufbau.

  • Modulare resistive und induktive Abschnitte ermöglichenunabhängiger Betrieb, easy calibration, and simplified servicing.

  • Parallel connection capability enables capacity expansion beyond 50 kVA for large-scale test systems.

  • Ensures smooth, stable transitions during load switching—reducing stress on test subjects and extending lifespan.


3. Advanced Control & Monitoring

  • Integriertdigital PLC control system with high-precision data acquisition.

  • Real-time display and recording of voltage, current, power, power factor, frequency, and temperature.

  • Optional remote control and data logging via Ethernet / RS485 / wireless interfaces.

  • Automated test sequences with programmable ramp rates, dwell times, and step loads—ideal for repetitive testing and certification workflows.

  • Safety interlocks prevent unintended operation during testing or maintenance.


4. Robust Industrial Construction

  • Heavy-duty, powder-coated steel enclosure ensures durability and corrosion resistance in harsh environments.

  • Entworfen fürindoor or outdoor operation, with high-efficiency forced-air cooling and thermostatically controlled fans.

  • All circuits are fully protected by overload breakers, fuses, and fault-detection systems.

  • Ausgestattet mitover-temperature, airflow failure, overload, emergency-stop, and load-dump protection mechanisms.

  • Engineered to operate continuously at full load without performance degradation, ensuring long service life and stable accuracy.


5. Prevents Generator “Wet Stacking” and Improves System Reliability

  • Regular load bank testing prevents wet stacking—the accumulation of unburned fuel and carbon deposits in diesel engines.

  • By simulating realistic load conditions, it ensures complete combustion and optimal generator efficiency.

  • Detects voltage drops, connection issues, insulation degradation, and cooling inefficiencies before they cause failures.

  • Essential for routine preventive maintenance in telecom, healthcare, data centers, and utility power plants.


6. Safety, Compliance & Long-Term Support

  • Built to meet or exceed international electrical and safety standards.

  • Each GROADA load bank undergoes full functional testing, calibration, and quality assurance before shipment.

  • Optional CE / ISO / UL-ready configurations available for compliance with global certification requirements.

  • Backed by GROADA’s comprehensive after-sales support, including commissioning assistance, spare parts supply, training, and remote diagnostics.


Technische Spezifikationen

ParameterSpezifikation
ModellAC 346V 50 kVA RL Load Bank
Rated Capacity50 kVA (resistive + inductive)
SpannungAC 346 V (3-phase, 50/60 Hz)
Leistungsfaktor0.8 (lagging)
Ladeschritte1 kW / 1 kVAR increments (customizable)
KühlmethodeForced air cooling with automatic fan control
ProtectionOver-temperature, airflow fault, overcurrent, emergency stop, short-circuit, load-dump
Control OptionsLocal control panel / Remote PLC / Network control
Enclosure RatingWeatherproof (IP54 / NEMA 3R optional)
Operating EnvironmentIndoor / Outdoor – -10 °C to +50 °C
ConstructionGalvanized steel with powder coating
ModularityExpandable capacity with parallel units

Anwendungen

The GROADA AC 346V 50 kVA RL Load Bank is engineered for a broad range of industrial and mission-critical applications, including:

  • Generator commissioning and maintenance
    Validate generator output, voltage regulation, and governor response under full load.

  • UPS and inverter testing
    Simulate both linear and reactive loads to confirm backup system reliability.

  • Transformer and switchgear evaluation
    Test equipment under realistic load and power factor conditions.

  • Data center and telecom infrastructure
    Conduct performance and redundancy tests for critical power systems.

  • Marine and offshore platforms
    Verify generator performance in remote or sea-borne installations.

  • Industrial process power systems
    Assess electrical infrastructure before live production.


Why Choose GROADA

  • Experience: Years of specialized manufacturing in resistive and reactive load banks for international markets.

  • Expertise: Engineering team experienced in generator testing, industrial automation, and electrical system design.

  • Authority: Products conform to global standards and are deployed across power generation, defense, oil & gas, and data center sectors.

  • Trustworthiness: Proven field performance, factory quality control, and strong after-sales technical support.

Every GROADA load bank is a reflection of our commitment to innovation, precision, and reliability. We work closely with OEMs, service contractors, and system integrators to deliver tailored power-testing solutions worldwide.


Safety & Compliance Commitment

Electrical testing involves high energy levels and potential hazards. GROADA ensures every RL Load Bank is designed with multi-layer protection, adhering to the latest international safety directives.
All units are subjected to full-load endurance tests, insulation verification, and thermal stability trials prior to delivery—ensuring your system operates safely, efficiently, and within specification throughout its life cycle.


Maintenance & Support

GROADA offers complete post-delivery services, including:

  • On-site installation and commissioning support

  • Operator training and technical documentation

  • Calibration and periodic inspection programs

  • Spare parts availability and rapid global logistics

  • Remote technical assistance and diagnostics

We ensure long-term operational stability and minimum downtime, protecting your investment and productivity.


Call to Action

Ensure your power systems are always ready for real-world performance.
Contact GROADA today to discuss your AC 346V 50 kVA RL Load Bank requirements, request a quotation, or schedule an engineering consultation.
Trust GROADA—your global partner in professional load testing and power reliability.