GROADA-AC220V-40KW-RCD Load Bank Lieferant

★★★★★
Hauptprodukte:
  • AC-Lastbank: R / RL / RLC / RCD
  • DC-Lastbank: DC5V - 2000V, 0A - 5000A


ModellAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V-30KW-RCDAC380V-50KW-RCDAC380V-60KW-RCDAC380V-100KW-RCDAC380V-200KW-RCD
NennleistungR = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
Eingangsstrom0 bis 22A0 bis 45A0 bis 45A0 bis 90A0 bis 45A0 bis 300A0-450A0 bis 600A0-750A
Größe (Breite * Tiefe * Höhe mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Gewicht50 kg80 kg100 kg130kg200 kg300 kg350 kg450kg550kg
EingangsspannungAC220 / 230VAC380 / 400V
Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden
Minimale Belastung100W100W100W100W100W1KW1KW1KW1KW
Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden
Gesamtgenauigkeit3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden)
LeistungsfaktorPF = 0,6 ~ 1,0
Spitzenkoeffizient2 bis 3
SteuermodusLokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden)
FernschnittstelleRS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden)
SchutzfunktionNotstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen)
ArbeitsstromversorgungAC220VAC220V / AC380V
Genauigkeit der Anzeige0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden)
AnzeigeparameterSpannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden)
Kalte sichere WeiseSeitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden)
SchutzstufeIP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden)
ErscheinungsfarbeRAL7035 (andere Farben können entsprechend Anforderungen angepasst werden)
Arbeitstemperatur-10 ℃ ~ 55 ℃
Relative Luftfeuchtigkeit ≤95% RH
Höhe ≤ 2500 m



GROADA AC220V 40kW RCD Load Bank: Hochpräzise nichtlineare Lastprüflösung

DieGROADA AC220V 40kW RCD Lastbankist ein modernstes Testgerät, das zur Simulation komplexer resistiver, kapazitiver und induktiver Belastungen entwickelt wurde. Es bietet Energietechnikern und Anlagenmanagern eine zuverlässige Lösung zur Überprüfung von Systemleistung, Stabilität und Widerstandsfähigkeit unter realen Betriebsbedingungen. Diese Ladebank ist ideal fürUPS-Systeme, Wechselrichter, Generatoren, Rechenzentren und andere kritische InfrastrukturUnterbrechungsfreier Betrieb und optimale Stromqualität gewährleisten.


🌟 Hauptmerkmale & Technische Spezifikationen

EigenschaftenSpezifikation
Nennleistung40 kW
SpannungAC 220V
LasttypRCD (Resistiv, Kapazitiv, Induktiv)
Leistungsfaktorbereich0.6 – 1.0
Frequenz50/60 Hz
Maximum Current180A
KühlmethodeForced Air Cooling
SteuerschnittstelleAdvanced Touchscreen with Real-Time Monitoring
SicherheitsmerkmaleOverload Protection, RCD Protection, Emergency Shutdown

DieRCD load configuration allows precise simulation of nonlinear electrical loads, enabling engineers to test how systems behave under realistic conditions. Its high-current capacity and adjustable power factor ensure flexibility in testing a wide range of equipment.


⚡ Applications

The GROADA AC220V 40kW RCD Load Bank is engineered for versatility across multiple industries:

  • UPS-Systemprüfung
    Evaluate uninterruptible power supplies under varying load conditions to ensure they can handle dynamic energy demands and maintain output stability.

  • Inverter Performance Validation
    Test inverters in renewable energy setups and industrial environments to measure response under non-linear loads.

  • Data Center Power Resilience
    Simulate realistic IT load profiles to verify critical infrastructure can sustain operations during peak and fluctuating demand.

  • Generator Lastprüfung
    Accurately simulate complex load patterns to ensure standby and emergency generators operate reliably under non-linear conditions.

  • Industrial Power Systems
    Analyze the impact of resistive, inductive, and capacitive loads on industrial motor drives, switchgear, and electrical distribution systems.


✅ Compliance with International Standards

The GROADA RCD Load Bank is built to meet global industry standards, ensuring safe, accurate, and reliable testing:

  • IEEE 1547 – Interconnection of distributed resources with electric power systems

  • NFPA 110 – Emergency and standby power system standards

  • ISO 8528-10 – Load acceptance procedures for generating sets

  • IEC 62040 – Performance and testing requirements for uninterruptible power systems

These certifications reflect the highest level of reliability, safety, and industry compliance, making it suitable for both commercial and industrial applications.


🔍 Advanced Performance Capabilities

The load bank’s advanced design allows for in-depth testing scenarios:

  • Dynamic Load Simulation
    Test power systems’ response to rapid load changes, simulating real-life operational conditions.

  • Harmonic Distortion Analysis
    Evaluate how non-linear loads affect voltage quality, equipment performance, and system efficiency.

  • Transient Response Testing
    Assess system stability during sudden changes, ensuring critical power systems maintain operational continuity.

  • Comprehensive Load Management
    Adjust resistive, inductive, and capacitive components independently to replicate a wide range of load behaviors.


🛠 Why Choose the GROADA AC220V 40kW RCD Load Bank?

  • Präzisionslastsimulation – Accurately replicates real-world nonlinear electrical loads for comprehensive system testing.

  • Benutzerfreundliche Schnittstelle – Intuitive touchscreen control with real-time monitoring simplifies operations and improves testing efficiency.

  • Robuste Sicherheitsmechanismen – Integrated protections safeguard both personnel and equipment during rigorous testing.

  • Versatile Industrial Applications – Suitable for data centers, renewable energy, industrial plants, and more.

  • Global Standards Compliance – Provides assurance of testing reliability and performance consistency across regions.

Investing in the GROADA RCD Load Bank ensures your critical power systems are rigorously tested, optimized, and ready for reliable operation under complex electrical loads. It is an indispensable tool for engineers, technicians, and facility managers seeking accuracy, safety, and efficiency in power system evaluation.