GROADA-AC220V-15KW-RLC Lastbank Hersteller
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| Modell | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Nennleistung | RLC = 10KVA | RLC = 30KVA | RLC = 60KVA | RLC = 100KVA | RLC = 200KVA | RLC = 300KVA |
| R = 10KW; L = 10KVA C = 10KVA | R = 30KW; L = 30KVA; C = 30KVA | R = 60KW; L = 60KVA; C = 60KVA | R = 100KW; L = 100KVA; C = 100KVA | R = 200KW; L = 200KVA; C = 200KVA | R = 300KW; L = 300KVA; C = 300KVA | |
| Andere Leistung kann entsprechend Anforderungen angepasst werden | ||||||
| Größe (Breite * Tiefe * Höhe mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Gewicht | 120 kg | 380kg | 580kg | 880kg | 1500 kg | 2500kg |
| Eingangsspannung | AC220 / 230V | AC380 / 400V | ||||
| Andere Eingangsspannung kann entsprechend Anforderungen angepasst werden | ||||||
| Eingangsstrom | 0 bis 45A | 0 bis 45A | 0 bis 90A | 0 bis 150A | 0 bis 300A | 0-450A |
| Minimale Belastung | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 100W; L = 100VA; C = 100VA | R = 1KW; L = 1KVA; C = 1KVA | R = 1KW; L = 1KVA; C = 1KVA |
| Andere Mindestlastleistung kann entsprechend Anforderungen angepasst werden | ||||||
| Leistungsfaktor | PF = 0,1 ~ 1,0 (anderer Leistungsfaktor kann entsprechend Anforderungen angepasst werden) | |||||
| Gesamtgenauigkeit | 3% (andere Genauigkeitsanforderungen können entsprechend Anforderungen angepasst werden) | |||||
| Steuermodus | Lokaler manueller / Remote-Hostcomputer (lokaler manueller Steuermodus: Schalter / Taste / Touchscreen dreiwegig optional, andere Methoden können nach Bedarf angepasst werden) | |||||
| Fernschnittstelle | RS232/RS485/USB/RJ45/CAN/GPIB (andere Schnittstellenmodi können entsprechend Anforderungen angepasst werden) | |||||
| Schutzfunktion | Notstandsschutz, Übertemperaturschutz, Lüfterlast-Verriegelungsschutz, Erdungsschutz (wählen Sie Überspannungsschutz, Überstromschutz, Kurzschlussschutz, Lüfterüberlast, unzureichendes Luftvolumen) | |||||
| Arbeitsstromversorgung | AC220V | AC220V / 380V | AC380V | |||
| Genauigkeit der Anzeige | 0,5 Ebene (andere explizite Präzision kann entsprechend Anforderungen angepasst werden) | |||||
| Anzeigeparameter | Spannung, Strom, Leistung, Frequenz, Leistungsfaktor usw. (andere explizite Methoden können entsprechend Anforderungen angepasst werden) | |||||
| Kalte sichere Weise | Seitenlufteinlass und oberer Luftauslass (andere Luftauslassmethoden können entsprechend Anforderungen angepasst werden) | |||||
| Schutzstufe | IP20 (andere Schutzebene können entsprechend Anforderungen angepasst werden) | |||||
| Erscheinungsfarbe | RAL7035 (andere Farben können entsprechend Anforderungen angepasst werden) | |||||
| Arbeitstemperatur | -10 ℃ ~ 55 ℃ | |||||
| Relative Luftfeuchtigkeit | ≤95% RH | |||||
| Höhe | ≤ 2500 m | |||||
Ensure Optimal Performance, Reliability, and Safety Across Your Power Infrastructure
DieGROADA AC380V 20KW RLC Load Bank is a high-performance testing solution designed for validating the reliability and efficiency of power generation and distribution systems. Combining resistive, induktive und kapazitive Belastungen, it simulates real-world electrical conditions, enabling engineers and technicians to identify potential issues before they become critical failures.
Whether for generators, UPS systems, data centers, or renewable energy integration, this load bank delivers precise, repeatable, and safe testing results, ensuring your critical power systems operate at peak efficiency under any scenario.
Incorporates resistive (R), induktive (L) und kapazitive (C) Lasten to accurately replicate the behavior of real electrical systems.
Allows precise simulation of different load types, including reactive and non-linear loads.
Supports a wide power factor range from 0.1 to 1.0, enabling testing under various operating conditions.
Critical for validating system performance in applications where reactive loads are present.
Modular architecture ensures easy scalability and allows customization based on specific testing needs.
Compact, robust, and transportable design ensures versatility in both field and laboratory environments.
Intuitive control panel provides real-time monitoring of voltage, current, power, and power factor.
Optional remote control functionality allows for safe operation from a distance.
Ausgestattet mitoverload protection, short-circuit protection, and over-temperature alarms.
Ensures operator safety and prevents damage to both the load bank and tested equipment.
Simulates realistic load conditions to verify generator performance, efficiency, and reliability.
Ensures compliance with operational standards and minimizes the risk of failure during peak demand.
Tests UPS functionality under varied resistive, inductive, and capacitive loads.
Ensures backup power systems maintain reliability during outages.
Evaluates solar, wind, or hybrid power systems under dynamic load conditions.
Helps optimize inverter and storage system performance for consistent energy delivery.
Confirms that backup power systems and generators can handle high-demand, critical loads.
Prevents downtime and ensures business continuity.
The GROADA AC380V 20KW RLC Load Bank is designed to meet international safety and performance standards, ensuring both reliability and operational compliance:
IEEE 1547 – Standard for testing distributed energy resources.
NFPA 110 – Requirements for emergency and standby power systems.
ISO 8528-10 – Load acceptance testing standards for generating sets.
Compliance with these standards guarantees that the load bank can be safely and effectively integrated into professional power testing environments worldwide.
Reliability Assurance – Early detection of system weaknesses prevents critical failures.
Performance Optimization – Testing under real-world load conditions ensures generators, UPS units, and other systems perform efficiently.
Cost Efficiency – Proactive testing reduces costly emergency repairs and downtime.
Operational Confidence – Verifies that backup power systems are ready for emergency operation.
| Spezifikation | Details |
|---|---|
| Nennleistung | 20KW |
| Spannung | AC380V |
| Frequenz | 50/60Hz |
| Leistungsfaktor | 0.1 – 1.0 |
| Steuermodus | Local panel and optional remote |
| Sicherheitsmerkmale | Overload, short circuit, over-temp alarms |
GROADA RLC Load Banks are trusted globally by power generation companies, data centers, and critical infrastructure operators. Our solutions are engineered for accuracy, durability, and ease of use, providing peace of mind for engineers and facility managers alike.
Email: groadacn@163.com
Phone: +86-755-23339096
Address:Shenzhen, Guangdong, China